Page 83

Operation Powering On/Off Connect the VX5 to a power source, either AC or Vehicle. The power (on/off) switch is located on the front of the VX5. The switch is sealed by a rubber membrane. The Status LED on the VX5 control panel is illuminated when the power is on: •

Green – VX5 is operating from vehicle or AC

•

Solid Yellow – VX5 is operating from the UPS

•

Flashing Yellow – VX5 is operating from the UPS, but UPS battery is critically low.

Press the power switch to start the VX5. You are now ready to use the computer. Enter data using the keyboard, touchscreen or a Serial Barcode Scanner. Note:

Always turn the computer off prior to connecting or disconnecting any power source.

VX5

Figure 74 The VX5 Power Switch The VX5 is designed for a controlled shutdown when using the power switch. A controlled shutdown first closes any open programs, and then shuts down the Windows operating system. DO NOT remove power from the VX5 without shutting down the VX5. The VX5 shutdown may be initiated in any of the following ways: •

Selecting the “Shut Down” option from the Windows Start Menu.

•

Selecting the “Shut Down” option from the Windows Task Manager. The Windows Task Manager is displayed by pressing Ctrl-Alt-Del.

•

Momentarily pressing and releasing the power button. The VX5 behavior when the power button is pressed can be configured in the Windows Control Panel.

•

Pressing and holding the power button for approximately five seconds. Any open programs and the Windows operating system are shut down before power off. Use this option to shut down the VX5 when the operating system is not responding. For more information on the Windows shutdown process, please refer to the Windows help function or commercially available Windows help guides.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 84

74

Powering On/Off

Reset Key Sequence (Reboot) Note:

The <CTRL> + <ALT> + <DEL> function can be used to shut down a Microsoft Windows application or reboot the computer. The keypress brings up the “Task Manager” window (Windows XP).

To reboot the VX5 without turning the computer off, press <CTRL> + <ALT> + <DEL> and select Shut Down from the Task Manager window. When the system is rebooted, Windows performs a controlled shutdown, closing any open programs, before shutting down the Windows operating system. The current contents of RAM are lost when rebooting. It is recommended to save any needed data and exit in an orderly fashion from any running programs before rebooting. When the VX5 is turned on or rebooted, the following settings are restored from flash memory and are configured using BIOS Setup. Note:

Options in the Microsoft Windows Control Panel make access to the BIOS unnecessary in many cases. Only those setting not controlled by Windows are listed below. For more information on Windows settings, please refer to commercially available Windows guides.

Factory Default Settings Boot Sequence

Removable Devices (i.e. USB floppy drive), Hard Drive, CDROM drive, Network boot (i.e. PXE) in this order

Legacy Floppy (A and B)

Disabled

Primary and Secondary Master and Slave drives

Auto

Display POST Msgs

Disabled

Show Summary Screen

Disabled

Note:

VX5 User’s Guide

This is a partial listing. Please review the instructions and warnings on modifying the BIOS in the “VX5 Reference Guide” before changing the BIOS. Use caution when changing BIOS settings as unexpected results may occur if improper values are used.

E-EQ-VX5OGWW-F-ARC

Page 85

Keyboard Backlight

75

Keyboard Backlight LXE VMT keyboards feature LEDs that illuminate the individual keys.

95 Key Keyboard The backlight is manually controlled using the “backlight” key in the upper right hand corner of the keyboard. Pressing the backlight key cycles the backlight through the levels of backlight intensity: •

Off

•

Maximum intensity

•

Medium intensity

•

Low intensity.

60 Key Keyboard The keyboard backlight may be toggled manually by pressing <2nd> + <CTRL> + <F10>. This key sequence immediately changes the state of the keyboard backlight as follows: •

Turns the backlight Off if it is currently On.

•

Turns the backlight On if it is currently Off.

PS/2 Keyboard Standard PS/2 keyboards generally do not feature keyboard backlighting.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 86

76

Display and Touchscreen

Display and Touchscreen The VX5 Display is a thin-film transistor display capable of supporting SVGA graphics modes. Display size is 800 x 600 pixels. The display covering is designed to resist stains. The touch screen allows signature capture and touch input. The touch screen is a Resistive Panel with a scratch resistant finish that can detect touches by a stylus, and translate them into computer commands. In effect, it simulates a computer mouse. Only Delrin or plastic styluses should be used. Note:

Always use the point of the stylus for tapping or making strokes on the display. Never use an actual pen, pencil or sharp object to write on the touch screen.

An extra or replacement stylus may be ordered from LXE. See the “Accessories” section for the stylus part number.

Adjusting Screen Display The color TFT display is an active source of light. The VX5 display brightness can be adjusted via the brightness control buttons located on the VX5 control panel. Pressing the brightness up button increases the display brightness incrementally until maximum brightness is achieved. Likewise, pressing the brightness down button decreases the display brightness until minimum brightness is achieved. Because there are 64 incremental levels of brightness intensity, a single press of either brightness adjustment button may not be noticeable. The up or down button can be pressed and held to accelerate brightness adjustment. Note:

The 2nd functions <F4>, <F5>, <F6>, and <F7> keys on the 60-key VMT keyboard have no function on the VX5.

There are no provisions for adjusting the contrast of the display. The display remains on unless Microsoft Windows power management is configured to turn the display off after a certain period of inactivity.

Cleaning the Display Keep fingers and rough or sharp objects away from the display. If the glass becomes soiled or smudged, clean only with a standard household cleaner such as Windex® without vinegar or use Isopropyl Alcohol. Do not use paper towels or harsh-chemical-based cleaning fluids since they may result in damage to the glass surface. Use a clean, damp, lint-free cloth. Do not scrub optical surfaces. If possible, clean only those areas which are soiled. Lint/particulates can be removed with clean, filtered canned air.

Disabling the Touchscreen The touchscreen can be disabled, if desired. For more information, please refer to “Disabling the Touchscreen” in the “VX5 Reference Guide”.

Touchscreen Protective Film LXE offers a replaceable touchscreen protective film to protect the touchscreen when the VX5 is used in an abrasive environment. Installation and removal instructions can be found earlier in this guide.

VX5 User’s Guide

E-EQ-VX5OGWW-F-ARC

Page 87

Display and Touchscreen

77

Calibrating the Touchscreen Although the touch screen is installed and calibrated at the factory, users may make adjustments to it by using the Fujitsu Touch Panel on the Microsoft Windows Programs menu. To calibrate the touchscreen, select Start | Programs | Fujitsu Touch Panel (USB) | Touch Screen Calibration Utility.

Figure 75 Touchscreen Calibration, Calibration Targets The calibration utility displays a red cross on the screen. Touch the center of the cross with the stylus and hold for a few seconds. Release and repeat with the next cross. After all twelve locations have been touched, either press <Enter> or click the Calibration button.

Figure 76 Touchscreen Calibration, Save Calibration To save the new calibration settings, click on the Save & Exit button or press <Enter>. To discard the new calibration settings, click Cancel & Exit or press <Esc>.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 88

78

Adjust Speaker Volume

Adjust Speaker Volume Microsoft Windows provides volume adjustment by clicking the “volume” icon in the system tray. The volume control adjusts the built in speaker’s volume. Note:

The <F8> and <F9> keys on the 60-key VMT keyboard have no function as Windows controls the sound volume.

Microsoft Windows Event Sounds The VX5 includes a customized sound scheme. The customized WAV files are preferable to the standard Microsoft Windows sounds when using the internal speakers. When a VX5 is delivered with Windows preinstalled, the customized sound scheme is the default for Windows events. If a VX5 is ordered with no operating system installed, the customized sounds can be found on the VX5 CD. For more information on changing the sounds used in Windows, please refer to the Windows Help feature. Please refer to the “VX5 Reference Guide” for more details on the VX5 CD.

VX5 User’s Guide

E-EQ-VX5OGWW-F-ARC

Page 89

Power Management

79

Power Management All Power Management is handled through the Microsoft Windows Control Panel. System standby and turning the monitor and hard disk off are accessed from the Power Management icon.

Figure 77 Microsoft Windows Power Management For more information on configuring Microsoft Windows Power Management, please refer to the Windows Help feature. The Power Management defaults for the VX5 are:

Note:

System standby

Never

Turn off monitor

After 15 minutes

Turn off hard disks

After 1 hour

When configuring power management, consider that the VX5 continues to draw power from the vehicle battery when not in use. When power management is used, the drain on battery power during periods of inactivity is minimal.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 90

80

Laser Barcode Scanner Warnings

Laser Barcode Scanner Warnings •

Do not look into the laser’s lens.

•

Do not stare directly into the laser beam.

•

Do not remove the laser caution labels from the scanner.

•

Do not connect the laser barcode module to any other device.

Caution:

!

Please read the caution labels. Avoid exposure. Laser light is emitted from the scanner’s aperture. Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. The scanner uses laser light. The following labels are representations of caution and warning labels placed on laser scanners.

IEC 825-1 1993 1ST ED.

LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT

IEC 825-1 1993 1ST ED.

1.0 mW - 675nm

LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 3A LASER PRODUCT 2.5 mW - 675nm

CAUTION

CAUTION

LASER RADIATION. DO NOT STARE

DO NOT STARE INTO BEAM 630-680nm LASER 1.0 MILLIWATT MAX OUTPUT

OPTICAL INSTRUMENTS.

675nm LASER 2.5 MILLIWATT MAX OUTPUT

CLASS II LASER PRODUCT

CLASS IIIA LASER PRODUCT

COMPLIES WITH 21 CFR 1040.10 1040.11 AND IEC825

COMPLIES WITH 21 CFR 1040.10 1040.11 AND IEC825

Figure 78 Caution Labels Class II Scanner

Figure 79 Caution Labels Class IIIA Scanner

Do not pour, spray, or spill any liquid on the scanner. The Barcode Scanner contains the circuitry, scanning motor and laser. Handle with appropriate care.

Enter Data You can enter data into the VX5 through several different methods:

VX5 User’s Guide

•

The tethered scanner connected to the COM1 serial port provides barcode data entry

•

The serial ports are used to input/output data

•

The keyboards provide manual entry

•

The touchscreen also provides manual entry

E-EQ-VX5OGWW-F-ARC

Page 91

Enter Data

81

Keyboard Entry Refer to “Appendix A Key Maps” for specific keypresses. The keyboard is used to manually input data that is not collected otherwise. Almost any function that a full sized computer keyboard can provide is duplicated on the LXE VMT keyboard but it may take a few more keystrokes to accomplish a keyed task. Almost every key has two or three different functions. The primary alpha or numeric character is printed on the key. For example, when the <2nd> key is selected pressing the desired second-function key produces the <2nd> character i.e. <2nd> + F1 toggles the CAPS Lock function. The specific <2nd> character is printed above the corresponding key. Please refer to “Appendix A Key Maps” for instruction on the specific keypresses to access all PC-compatible keyboard functions.

Touchscreen Entry Note:

This section is directed to the VX5 user. The assumption is that the unit has been configured and the touch panel calibrated by the System Administrator prior to releasing the VX5 for use.

Note:

Always use the point of the stylus for tapping or making strokes on the display. Never use an actual pen, pencil or sharp object to write on the touch screen.

The touchscreen input performs the same function as the mouse that is used to point to and click elements on a desk top computer. The stylus is used in the same manner as a mouse – single tap or double tap to select menu options, drag the stylus across text to select, hold the stylus down to activate slider bars, etcetera. The right mouse click function can be configured as follows: •

Press and hold <Ctrl> key then touch the touchscreen (this is the only option available with the 60-key keyboard).

•

Press and release <Ctrl> key then touch touchscreen..

When using a stylus, hold the stylus as if it were a pen or pencil. Touch an element on the screen with the tip of the stylus then remove the stylus from the screen. The touch screen responds to an actuation force (touch) of up to 4 oz. of pressure. The touch screen can be used in conjunction with the keyboard and an input/output device connected to one of the VX5’s serial ports. •

Touch the stylus to the field of the data entry form to receive the next data feed.

•

The cursor begins to flash in the field.

•

The unit is ready to accept data from either the keyboard or a device connected to a serial port.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 92

82

Enter Data

Scanner Entry The following section is directed toward a generic tethered scanner connected to the COM1 serial port on the VX5.

Aiming the Barcode Scanner Aim the scanner away from you, direct it at the barcode and press the trigger to scan. The Scan On LED (or equivalent) turns red to indicate the scanner is on. Adjust the aim so that the thin, red laser beam covers the entire length of the barcode. Some scanners use a laser aiming beam which then spreads into a wide beam when the scanner’s Aiming Beam Timer expires. Place the aiming beam in the center of the barcode and hold the scanner steady until the beam spreads and the barcode is decoded. Beeps may be heard as the barcode is decoded. Refer to the barcode scanner user’s guide for information on the Aiming Beam Timer and beep sequences, and the TE reference guide for host generated beep sequences. The scan beam must cross every bar and space on the barcode.

Correct Scan

Incorrect Scan

Incorrect Scan

Figure 80 Scan Beam

Distance from Label Large barcodes can be scanned at the maximum distance. Hold the scanner closer to small barcodes (or with bars that are very close together). Note:

Do not position the scanner exactly perpendicular to the barcode being scanned. In this position, light can bounce back into the scanner’s exit window, and possibly prevent a successful decode.

Successful Scan When the scan is successful, the scanner’s good scan indicator illuminates, the scan on indicator is off, and the currently running application may produce a distinctive audible tone.

Unsuccessful Scan When the scan is unsuccessful, the scan on indicator remains illuminated and the currently running application may produce distinctive audible tones. Check the following:

VX5 User’s Guide

•

Is the scanner programmed for the barcode being read?

•

Check the barcode for marks or physical damage e.g. ripped label, missing section, etc.

•

Try scanning test symbols of the same code type at different distances and angles.