Page 65

Connect Serial Barcode Scanner

55

Connect Serial Barcode Scanner Refer to the documentation received with the barcode scanner for complete instructions. Read all warnings and caution labels.

!

Pin 9 of COM1 is configured to provide +5V. Pin 9 of COM2 is configured to provide RI. To change Pin 9 of either port, please refer to the “VX5 Reference Guide”. The scanner cable is attached to the connector marked “COM1/SCANNER”. The scanner receives power from the VX5. The cable requires a nine-pin D-shell female connector for the VX5. Note:

Use of a shielded cable is required to maintain FCC and CISPR22 emissions compliance.

IP66

!

LISTED I.T.E.

REFER TO MANUAL

N107

C

UL US ®

E-130794

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada

PRODUCT OF U.S.A. U.S. PATENT 5862393

CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.

AUDIO INPUT: 12-80VDC 6A 72W

COM1 / SCANNER

COM2/3

KEYBOARD / MOUSE

ETHERNET / USB

T10A, 125V

Figure 51 Connect Serial Scanner Cable 1.

Seat the connector firmly over the pins and turn the thumbscrews in a clockwise direction. Do not overtighten.

2.

Use a strain relief clamp to secure the cable.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 66

56

Connect Serial Barcode Scanner When you have finished using the scanner, remove it from the VX5 and store the scanner in a closed container or bag.

VX5

Figure 52 VX5 with Generic Barcode Scanner Attached

1. Good Scan LED (or equivalent) 2. Trigger 3. Laser Aperture at Front

Figure 53 Generic Barcode Scanner Refer to the documentation received with the barcode scanner for complete instructions.

VX5 User’s Guide

E-EQ-VX5OGWW-F-ARC

Page 67

Connect Serial Printer or PC

57

Connect Serial Printer or PC Refer to the documentation received with the printer or PC for complete instructions. Pin 9 of COM1 is configured to provide +5V. Pin 9 of COM2 is configured to provide RI. To change Pin 9 of either port, please refer to the “VX5 Reference Guide”. The printer or PC cable requires a nine-pin D-shell female connector for the VX5. The printer or PC cable is attached to the COM2 connector. COM2 may be labeled as either “COM2” or “COM2/3”. Note:

Use of a shielded cable is required to maintain FCC and CISPR22 emissions compliance.

IP66

!

LISTED I.T.E.

REFER TO MANUAL

N107

C

UL US ®

E-130794

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada

PRODUCT OF U.S.A. U.S. PATENT 5862393

CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.

AUDIO INPUT: 12-80VDC 6A 72W

COM1 / SCANNER

COM2/3

KEYBOARD / MOUSE

ETHERNET / USB

T10A, 125V

Figure 54 Connect Serial Cable to COM2 1.

Seat the connector firmly over the pins and turn the thumbscrews in a clockwise direction. Do not over tighten.

2.

Use a strain relief clamp to secure the cable.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 68

58

Connect USB Devices

Connect USB Devices The VX5 provides an internal USB port and a provision for an external USB port via a dongle cable attached to the connector marked “ETHERNET/USB” .

Internal USB Port An internal USB port is provided behind the user access panel on the top of the VX5. 1.

Loosen the three (3) Phillips head screws securing the access panel cover so the cover can be removed. The screws are a captive part of the cover and cannot be removed.

2.

Plug the desired device, such as a USB mouse or floppy drive, into the USB port. Refer to the documentation for your USB device for more details on installation. USB devices may be installed, removed or swapped without turning off the VX5.

!

3.

VX5 User’s Guide

While the access panel is open, the VX5 IS NOT environmentally sealed. The internal USB port should only be used when the VX5 is in a clean, dry, dust free environment. Use the external USB port if a USB device must be used in a harsh environment.

When finished with the USB device, unplug the device and reattach the user panel access cover. The three screws must be fastened to 9±1 inch pounds each. The screws require a Phillips size 1 driver head.

E-EQ-VX5OGWW-F-ARC

Page 69

Connect USB Devices

59

External USB Port An external USB connector is available via a dongle cable attached to the port marked “ETHERNET/USB”, located on the bottom of the VX5. 1 2 3

1

D15 Connector

2

RJ45 Connector

3

USB Connector

Figure 55 VX5 Ethernet/USB Dongle Cable

IP66

!

LISTED I.T.E.

REFER TO MANUAL

N107

C

UL US ®

E-130794

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada

PRODUCT OF U.S.A. U.S. PATENT 5862393

CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.

AUDIO INPUT: 12-80VDC 6A 72W

COM1 / SCANNER

COM2/3

KEYBOARD / MOUSE

ETHERNET / USB

T10A, 125V

Figure 56 Connect Ethernet/USB Dongle Cable 1.

Insert the watertight-connector end of the Ethernet/USB dongle cable into the VX5 Ethernet/USB connector. Seat the connector firmly over the pins and turn the thumbscrews in a clockwise direction. Do not over tighten.

2.

Use a strain relief clamp to secure the cable.

Figure 57 Connect USB Device to Dongle Cable 3.

Plug the desired device, such as a USB mouse or floppy drive, into the end of the dongle cable with the USB port. Refer to the documentation for your USB device for more details on installation. USB devices may be installed, removed or swapped without turning off the VX5. Note:

E-EQ-VX5OGWW-F-ARC

The USB Host Controller (or USB Port) must be enabled in the BIOS. To use a USB floppy drive, USB BIOS Legacy Support must be enabled. For more information, please refer to the “VX5 Reference Guide”.

VX5 User’s Guide

Page 70

60

Connect Ethernet Cable

Connect Ethernet Cable An Ethernet connector is available via a dongle cable attached to the port marked “ETHERNET/USB”, located on the bottom of the VX5. 1 2 3

1

D15 Connector

2

RJ45 Connector

3

USB Connector

Figure 58 VX5 Ethernet/USB Dongle Cable

IP66

!

LISTED I.T.E.

REFER TO MANUAL

N107

C

UL US ®

E-130794

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada

PRODUCT OF U.S.A. U.S. PATENT 5862393

CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.

AUDIO INPUT: 12-80VDC 6A 72W

COM1 / SCANNER

COM2/3

KEYBOARD / MOUSE

ETHERNET / USB

T10A, 125V

Figure 59 Connect Ethernet/USB Dongle Cable 1.

Insert the watertight-connector end of the Ethernet/USB dongle cable into the VX5 Ethernet/USB connector. Seat the connector firmly over the pins and turn the thumbscrews in a clockwise direction. Do not over tighten.

2.

Use a strain relief clamp to secure the cable.

Figure 60 Connect Ethernet Cable to Adapter Cable

VX5 User’s Guide

3.

Insert the network cable and ensure it is firmly seated in the connector jack.

4.

To remove the Ethernet cable, press the release tab on the cable end.

E-EQ-VX5OGWW-F-ARC

Page 71

Connect External Headset

61

Connect External Headset The VX5 provides an external headset connection via an audio jack connector marked “Audio”. The audio jack accepts a headset with a 2.5mm plug, such as a mono telephone headset with microphone.

IP66

!

LISTED I.T.E.

REFER TO MANUAL

N107

C

UL US ®

E-130794

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada

PRODUCT OF U.S.A. U.S. PATENT 5862393

CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.

AUDIO INPUT: 12-80VDC 6A 72W

COM1 / SCANNER

COM2/3

KEYBOARD / MOUSE

ETHERNET / USB

T10A, 125V

Figure 61 Connect External Headset 1.

Insert the speaker or headphone plug into the audio connector; making sure the plug is firmly seated in the audio jack.

2.

Replace the plug when the speaker or headset is removed from the audio jack.

3.

Use a strain relief clamp to secure the cable.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 72

62

Connect Power Cable and Optional UPS Battery Pack

Connect Power Cable and Optional UPS Battery Pack 1.

Turn the VX5 off before attaching the power plug.

2.

Connect the power cable to vehicle power (See the following section titled “Vehicle 12-80VDC Direct Connection.”) - or to an AC adapter. (See the following section titled “External Power Supply.”).

3.

Several possibilities are available for routing the vehicle power to the VX5. See the following section titled “Vehicle 12-80VDC Direct Connection” for details.

4.

All plugs and receptacles are keyed and care must be used when connecting the cables. Tighten the nut of the plugs clockwise until tight. Secure the cable with the strain relief cable clamps.

IP66

!

LISTED I.T.E.

REFER TO MANUAL

N107

C

UL US ®

E-130794

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada

PRODUCT OF U.S.A. U.S. PATENT 5862393

CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.

AUDIO INPUT: 12-80VDC 6A 72W

COM1 / SCANNER

COM2/3

KEYBOARD / MOUSE

ETHERNET / USB

T10A, 125V

Figure 62 Connect Power Cable to VX5 5.

VX5 User’s Guide

Turn the VX5 on.

E-EQ-VX5OGWW-F-ARC

Page 73

External Power Supply, Optional

63

External Power Supply, Optional The LXE-approved AC Power Adapter is only intended for use in a 25ºC (77ºF) maximum ambient temperature environment.

1

2

1. AC Input Cable (US only) 2. DC Output Cable

Figure 63 Optional Power Configuration In North America, this unit is intended for use with a UL Listed ITE power supply with output rated 12 – 80 VDC, minimum 75W. Outside North America, this unit is intended for use with an IEC certified ITE power supply with output rated 12 – 80 VDC, minimum 75W. The external power supply may be connected to either a 120V, 60Hz supply or, outside North America, to a 230V, 50Hz supply, using the appropriate detachable cordset. In all cases, connect to a properly grounded source of supply provided with maximum 15 Amp overcurrent protection (10 Amp for 230V circuits). How To: Connect External Power Supply 1.

Turn the VX5 off.

2.

Connect the detachable cordset provided by LXE (US only, all others must provide their own cable) to the external power supply (IEC 320 connector).

3.

Plug cordset into appropriate, grounded, electrical supply receptacle (AC mains).

4.

Connect the watertight connector end to the VX5’s Power Connector by aligning the connector pins to the power connector; push down on the watertight connector and twist it to fasten securely.

5.

Turn the VX5 on.

E-EQ-VX5OGWW-F-ARC

VX5 User’s Guide

Page 74

64

Vehicle 12-80VDC Power Connection

Vehicle 12-80VDC Power Connection For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle. This fused circuit requires a 10 Amp maximum time delay (slow blow) high interrupting rating fuse. If the supply connection is made directly to the battery, the fuse should be installed in the positive lead within 5 inches of the battery positive (+) terminal.

Caution:

!

For installation by trained service personnel only.

Caution:

! Warning:

!

Risk of ignition or explosion. Explosive gas mixture may be vented from battery. Work only in well ventilated area. Avoid creating arcs and sparks at battery terminals.

1. To Vehicle Battery 1

+

GND

2

2. To Vehicle Mounted Device or UPS Battery Pack 3. White (DC+)

3 6

4

4. Black (DC-)

5

5. Green (GND) 6. 12 – 80 VDC Figure 64 Vehicle Power Connection Cable (Fuse Not Shown) 1. Vehicle Electrical System 2. 10 Amp Slow Blow Fuse

1 2 3

3. DC + 6 7

4 8 5

4. DC 5. Vehicle Chassis 6. White 7. Black 8. Green

Figure 65 Connecting the Power Cable to the Vehicle Note:

VX5 User’s Guide

Correct electrical polarity is required for safe and proper installation. Connecting the cable to the VX5 with the polarity reversed will cause the VX5’s fuse to be blown. See the following figure titled “Vehicle Connection Wiring Color Codes” for additional wire color-coding specifics.

E-EQ-VX5OGWW-F-ARC