For the LXE 6224

Page 19

Chapter 2 Hardware Configuration

Introduction Place the 6224 Session Manager (and the personal computer (PC) that will function as the “dumb terminal”) in a location where a steady, reliable electric power source is available. A functional Ethernet network is required. Materials needed for hardware configuration: •

6224 to PC -- null modem cable or equivalent

•

Ethernet cables and connectors

Warning: Mise en garde: Warnung: Attenzione: Aviso: Advertencia: Varning:

E-SW-6224RG-F-ARC

The 6224 must be connected to earth ground. (US) Cet appareil doit être relié à la terre. (FR) Diese Gerät muß geerdet sein. (DE) Questa apparecchiatura deve essere collegata a terra. (IT) Este equipamento deve ter uma ligação à terra. (PT) Este equipo se debe conectar a tierra física. (ES) Denna utrustning måste jordas. (SE)

6224 Session Manager Reference Guide

Page 20

10

Front Panel

Front Panel

Figure 2-1 Indicators on Front Panel of 6224

MEMORY CARD

The MEMORY CARD slot accepts a Personal Computer Memory Card Industrial Association (PCMCIA) memory card to download software into Flash RAM.

CONSOLE TX

The CONSOLE TX LED lights when the 6224 transmits data to the PC being used for configuration (set-up).

CONSOLE RX

The CONSOLE RX LED lights when the 6224 receives data from the PC being used for configuration (set-up)..

HOST TX

The HOST TX LED has no function.

HOST RX

The HOST RX LED has no function.

HOST RTS

The HOST RTS LED has no function.

HOST CTS

The HOST CTS LED has no function.

SYSTEM RUN

The SYSTEM RUN LED blinks on and off when the 6224 is operating.

SYSTEM ALARM

The SYSTEM ALARM LED lights when an alarm (fault) condition is detected.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 21

Back Panel

11

Back Panel

Figure 2-2 6224 Connectors on Back of 6224 Power Panel

Connects an AC power source at the Power Connector and switches power to the 6224 using the On/Off Switch.

Ethernet Ports

The Ethernet ports (THINNET, AUI, and TPE) require different types of cable to connect the 6224 to the Ethernet:

THINNET

The THINNET port connects to Thinnet cable, as defined by the IEEE 802.3 10Base2 specification. Thinnet is RG 58A/U coaxial cable.

AUI

The Attachment Unit Interface (AUI) port connects to a transceiver that connects to the IEEE 802.3 standard 10Base5 backbone coaxial cable, also known as thick Ethernet.

TPE

The Twisted Pair Ethernet (TPE) port is a RJ-45 modular telephone connector that connects to IEEE 802.3 standard 10BaseT twisted pair cable.

RXD

The RXD (Receive Data) LED lights when the 6224 series device receives data from the Ethernet.

TXD

The TXD (Transmit Data) LED lights when the 6224 series device transmits data to the Ethernet.

AUX Port

Has no function.

Console Port

Connects the 6224 to a dumb terminal or standalone computer for configuration (set-up).

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 22

12

Cable Connections

Cable Connections Connect 6224 to PC

Figure 2-3 Connect using Null Modem Cable How To Note:

Use a reliable AC power source while programming the 6224.

1.

Place the power switches in the OFF (0) position on the 6224 and the “dumb terminal” (a personal computer running a terminal emulation program e.g. Procomm) before attaching the null modem cable.

2.

Connect the 9-pin end of the null modem cable to the 9 pin serial port of the PC and fasten securely.

3.

Connect the 25-pin end of the null modem cable to the 25 pin Console port of the 6224 and fasten securely.

4.

Connect the power cable to the 6224 and plug into a grounded, electrical supply receptacle.

5.

Connect a power cable to the PC and a grounded, electrical supply receptacle.

6.

Turn the 6224, PC and PC’s monitor on.

7.

You are now ready to begin programming the 6224.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 23

Cable Connections

13

Connect Ethernet Cable Place the 6224 power switch in the OFF position (0) before connecting Ethernet cables to the 6224. Note:

Only one type of Ethernet connection is used at a time -- either Thinnet, AUI or UTP.

•

Check your local building/electrical code; it may require that the cable be enclosed in metal conduit.

•

Install junction boxes at transceiver locations if the cable is installed in conduit.

•

Support the cable at least every 3 feet by cable clamps or similar means if the cable is not to be enclosed in conduit.

•

Do not route the cable in close proximity (for example, within a 4 ft. radius) to any high voltage or high current-carrying electrical lines.

•

Route the cable so that it is out of sight or reach of curious personnel.

•

Do not exceed 30 T-connector taps on a Thinnet (10Base2) line. Keep a minimum distance between taps of 0.5 meters.

•

Do not exceed 100 transceiver taps on a thick Ethernet (10Base5) line.

•

Keep a distance between taps of a multiple of 2.5 meters.

•

Do not use an AUI cable longer than 50 meters for (10Base5) Ethernet.

Guidelines

Use the LXE Facility Analysis Report If an LXE Facility Analysis report is available, it will indicate the recommended cable type, routing path, and cable length. Ensure that your equipment is Ethernet LAN compliant.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 24

14

Cable Connections

Thinnet

Figure 2-4 Thinnet Connector Both the connector on the cable and the connector on the 6224 are keyed and cannot be connected incorrectly. Push in and twist the housing on the Ethernet connection clockwise until tight.

Attachment Unit Interface (AUI)

Figure 2-5 AUI Connector Seat the 15-pin AUI Ethernet cable connection on the pins of the 15-pin AUI connector on the 6224. Do not bend the pins. Push the slide-lock sideways to lock the connection when the face of the AUI Ethernet connector is flush with the face of the AUI connector on the 6224.

Twisted Pair Ethernet (TPE)

Figure 2-6 TPE Connector Gently push the TPE Ethernet RJ-45 connector into the TPE connector on the 6224 until the tab clicks into place and the connection is secure.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 25

Cable Connections

15

Connect Power Cable

Figure 2-7 Connect Power Cable to 6224 How To 1.

Turn the 6224 off (0).

2.

Plug the three prong end of the cordset, provided by LXE, into an appropriate, grounded, electrical supply receptacle.

3.

Connect the female end of the cordset to the power connector on the 6224 and push firmly to fasten securely.

4.

Turn the 6224 on ( I ).

5.

The System Run LED begins to blink indicating that the 6224 is receiving electrical power.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 26

16

6224 Session Manager Reference Guide

Cable Connections

E-SW-6224RG-F-ARC