The text of a manual · part 4 of 10

6224 Session Manager Reference Guide: Chapter 3 Software Configuration, pages 27 to 35

Pages 27 to 35 of 78, from 6224 Session Manager Reference Guide

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the LXE 6224

Page 27

Chapter 3 Software Configuration Introduction There are two different configuration methods available: local and remote. A complete setup can be performed using the local method. Most (not all) of the setup parameters can be configured using the remote (Telnet) method. The local method requires the use of a “dumb terminal” (a personal computer running a terminal emulation program e.g. Procomm) physically connected to the 6224 console connector. The remote method requires the use of a Telnet capable PC connected to the wired network. You must use the local method when changing the 6224 IP address, subnet mask, gateway address and flags as these values cannot be set remotely using a Telnet connection unless the 6224 can communicate over the user's network. Note:

When working with a 6224 in an ANSI or LDS system, the on-screen text displayed for each terminal's network connection is "secondary ID". When working with a 6224 in an IBM system, the on-screen text displayed for each terminal's network connection is "IP address".

Initial Setup See Chapter 2 “Hardware Configuration” section titled “Connect 6224 to PC” for instructions on local PC connection, via null modem cable (or equivalent), to a 6224. The initial setup of the 6224 entails the setting of certain “boot” parameters. The boot parameters can only be programmed using the “local” configuration method. These boot parameters are: •

IP address of the 6224 session manager.

•

Subnet mask.

•

Gateway (router) address.

•

“Flags” value.

The remainder of the setup parameters can be programmed using either the local or remote method.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 28

18

Initial Setup

PC Comm Port Setup New or initial setup 6224 hardware does not contain a valid IP address. Thus, the initial setup must be performed using the local method via connection to a PC running a terminal emulation program (“dumb terminal”). During the initial setup the IP address, subnet mask, and gateway address can be set. Also, the flags value can be viewed and adjusted if necessary. The “dumb terminal” function can be provided by a PC running a terminal emulation program like Procomm, or Hilgrave’s Hyper Terminal (included with Windows 95) or any similar program. The terminal emulation program should be setup with: 9600 baud 8 data bits No parity 1 stop bit Use a null modem cable (or equivalent) to connect the Console connector of the 6224 to the Com port of the PC that is running the terminal emulation program.

Boot Parameters The following table reflects the boot default values used when the NVRAM has been cleared. Parameter

Default Value boot device nce processor number

0 host name nc file name flash inet on ethernet (e)

0.0.0.0 inet on backplane (b) host inet (h) gateway inet (g) user (u)

vxworks ftp password (pw) (blank = use rsh)

lxe302 flags (f)

0x840 target name (tn) startup script (s) other (o)

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 29

Initial Setup

19

Boot Text During boot, the 6224 sends data regarding the boot process out through its console port. The boot data can be monitored on a dumb terminal that is connected to the 6224 console connector. Following is an example of the text that a 6224 outputs during boot. An explanation of each line of text is presented on the following pages. Line # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38

Actual boot text for ANSI 6224 ~~~+++~~~ Detected 1MB of Flash memory. HARDWARE CONFIGURATION CPU: Motorola MC68302 Memory Size (hexadecimal): 0x80000. Made on Tue Nov 4 13:22:11 EST 1997. Starting auto-boot process for hardware and network components. Press the Enter key before the countdown reaches 0 to stop autoboot... 3 - 2 - 1 - 0 auto-booting... Executing application starting at address 0x840000... HARDWARE CONFIGURATION CPU: Motorola MC68302 Memory Size (hexadecimal): 0x100000. Made on NO DATE STAMP. Attaching ethernet network interface ... passed passed NICE receive and transmit loopback tests passed done. Installing network module Installing Telnet module Installing ftpserver module Installing monitoring utility netShow Delaying 3 seconds to allow the route table to be filled. Press any key before countdown reaches 0 to stop application autoboot... 3 - 2 - 1 - 0 Application Software started: Session Manager Version: No version defined 001:Host Module: SessMgr -- supports 128 terminals – 002:ALL PRINTFs disabled (including PM_ABNORM) 003: smdebug: Disable ALL PRINTFs 004: smdebug 1: Enable debug PRINTFs 005: smdebug 2: Enable only non-verbose PM_ABNORM 006: smr: Enable all PM_ABNORM Session mgr NVRAM key is not VALID 008: SessMgr hostModInit(): SUCCESSFUL

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 30

20

Initial Setup

Details of the Boot Text The “line numbers” in the preceding example of the boot text have been included to simplify the explanation of the individual lines. When observing the text on the dumb terminal the line numbers will not be included with the text. Following are details of the lines of the boot text: Line 1

~~~+++~~~

The three tilde, three plus, three tilde indicate the start of the boot. This line is included to initialize a modem if a modem link is being used to connect a remote device to the console connector of the 6224. Line 2

Detected 1MB of Flash memory.

This just indicates that one Meg of flash memory has been detected. One Meg of flash memory is normal. Line 3 Line 4 Line 5

HARDWARE CONFIGURATION CPU: Motorola MC68302 Memory Size (hexadecimal): 0x80000.

Indicates details of the hardware configuration of the 6224. The Motorola MC68302 processor has been detected. It is the only CPU used in the 6224. The memory size refers to the RAM size in hex. Only one half Meg can be detected at this point. Actually, one Meg of RAM is installed. The full one Meg will be detected later in the boot process (see line14). Line 6

Made on Tue Nov 4 13:22:11 EST 1997.

The date the software was created. Line 7

Starting auto-boot process for hardware and network components. Line 8 Press the Enter key before the countdown reaches 0 to stop auto-boot... The boot process for hardware and network components is about to begin. A “count-down” from three down to zero will commence. If the [Enter] key on the dumb terminal is pressed before the count-down reaches zero the boot process will be halted. The boot process can be stopped -- which allows access to the operating system shell for special set-up procedures. Line 9

3 - 2 - 1 - 0

Here the count-down is displayed. This count-down is referred to as the “first countdown.” The second countdown occurs later in the boot process (see line 27). The boot process can be stopped during the first count-down to configure certain set-up parameters of the 6224. Line 10 auto-booting...

Since the [Enter] key was not pressed, during the count-down, the boot is proceeding. Line 11

Executing application starting at address 0x840000...

The code is being executed at memory location 0x840000 hex. That is the first location in flash memory. Line 12 Line 13 Line 14

HARDWARE CONFIGURATION CPU: Motorola MC68302 Memory Size (hexadecimal): 0x100000.

This is a repeat of the information on lines 3, 4, and 5. The only difference is that here the full one Meg of RAM is now detected. Line 15

Made on NO DATE STAMP.

The date the software was created.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 31

Initial Setup

21 Line 16 Line 17 Line 18 Line 19 Line 20 Line 21 Line 22 Line 23 Line 24

Attaching ethernet network interface ... passed passed NICE receive and transmit loopback tests passed done. Installing network module Installing Telnet module Installing ftpserver module Installing monitoring utility netShow

The Ethernet hardware components of the 6224 are being tested and certain network software modules are being loaded. Line 25

Delaying 3 seconds to allow the route table to be filled.

The boot process is being delayed to allow the 6224 to receive route (RIP) information about the network to which it is connected. Line 26 Line 27

Press any key before countdown reaches 0 to stop application auto-boot... 3 - 2 - 1 - 0

This is the second count-down. Stopping the boot at this count-down is for very detailed indepth troubleshooting and debugging procedures which are reserved for LXE technical personnel. Line 28 Line 29

Application Software started: Version: No version defined

Session Manager

The application software is being executed and its version might be indicated. Line 30

001:Host Module: SessMgr -- supports 128 terminals –

Indicates the number of PCs the 6224 will support. Line 31 Line 32 Line 33 Line 34 Line 35

002:ALL PRINTFs disabled (including PM_ABNORM) 003: smdebug: Disable ALL PRINTFs 004: smdebug 1: Enable debug PRINTFs 005: smdebug 2: Enable only non-verbose PM_ABNORM 006: smr: Enable all PM_ABNORM

This is information provided for LXE Engineering personnel and displayed for ANSI and IBM only. Line 36

Session mgr NVRAM key is not VALID

If this data is displayed it does not indicate a problem. Once the 6224 is programmed with a default host or a host for an RF PC, this message will not be displayed. Line 37

008:

There is no data on this line. Line 38

SessMgr hostModInit(): SUCCESSFUL

This indicates that the 6224 completed its boot successfully.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 32

22

Initial Setup

Initial 6224 Setup Procedure Turn the 6224 on and allow it to complete its boot. Turn the PC and monitor on and run the terminal emulation program (e.g. Procomm). Press the [Enter] key of the PC and you should observe, on its display, the 6224 operating system prompt: ->

(hyphen greater than)

Setup commands listed in “Commands and Functions” later in this chapter are entered at this prompt. Setup commands not entered at this prompt are: • setting/changing the IP address of the 6224,

• the subnet mask,

• a gateway address

• and the flags value.

Power Cycle the 6224 The process is begun by power cycling the 6224 and stopping the auto-boot at a particular point during the auto-boot. The PC remains powered on during the 6224 power cycle. During auto-boot, the 6224 writes data to the display of the PC. The auto-boot process is halted by pressing the [Enter] key of the PC at the proper stage of the auto-boot.

Stop Auto-boot Process At an early point of the auto-boot the following words appear on the PC display

Press the Enter key before the countdown reaches 0 to stop auto-boot You have approximately three seconds to press the [Enter] key. If you miss this opportunity, you will have to cycle 6224 power again for another try. After successfully pressing the [Enter] key before the timeout expired, the auto-boot process stops and the LXE shell prompt: LXE-> (LXE hyphen greater than) should appear on the PC display.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 33

Initial Setup

23

Begin Change/Edit Process At the LXE shell prompt, type a lower case letter "c": LXE->c then press the [Enter] key. The following should appear on the PC display. ‘.’ = clear field; boot device

‘_’ = go to previous field; : nce

^D = quit

_

The boot device is the first of fourteen (14) boot parameters. At this point, press the [Enter] key. The second boot parameter will be added to the display. Each time [Enter] is pressed, another parameter line is added to the display. The only boot parameters that are applicable to the Session Manager are: inet on ethernet (including a subnet mask, if required. Default is 255.255.0.0 or 0xFFFF0000) gateway inet, if required flags All of the other parameters should be left unchanged.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 34

24

Initial Setup inet on ethernet (IP Address and Subnet Mask) At this point, repeatedly press the [Enter] key until the line inet on ethernet is added and the display appears as follows. ‘.’ = clear field;

‘_’ = go to previous field;

boot device processor number host name file name inet on ethernet (e)

^D = quit

: nce : 0 _ : nc : flash : 141.186.50.10 (or 0.0.0.0) _

The IP address that is currently displayed is the one that was previously programmed into the 6224. The address that appears might be all zeros (0.0.0.0). In either case, enter the IP address that you wish to assign to the 6224 and a subnet mask, if required. Note that a cursor is displayed following the last character of the current IP address. At the cursor location, enter the value of the IP address and subnet mask (if required) for the 6224. As the new IP address is entered, it is displayed to the right of the current IP address so that both the old and new addresses are displayed. If your network is composed of subnets, enter the subnet mask on the same line with the IP address. For example, assuming your IP address is 150.22.14.31, and your subnet mask is ffffff00, the boot parameters should look similar to the following: ‘.’ = clear field;

‘_’ = go to previous field;

boot device processor number host name file name inet on ethernet (e)

: nce : 0 _ : nc : flash : 141.186.50.10

^D = quit

150.22.14.31:0xffffff00_

Where 141.186.50.10 (or 0.0.0.0) is the original (old) IP address 150.22.14.31 is the new IP address and ffffff00 is the subnet mask in hexadecimal notation. The colon (:) is a required delimiter that separates the IP address from the subnet mask. The 0x indicates that the subnet mask is in hexadecimal notation. The ffffff00 hex value represents the decimal value 255.255.255.0. The subnet mask must be entered in hexadecimal format. When you have finished entering the address and subnet mask (if required), press the [Enter] key which will cause the next line of the boot parameters to be added to the display.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 35

Initial Setup

25 gateway inet (Gateway / Router IP Address) At this point, repeatedly press the [Enter] key until the line gateway inet is added to the display. The display should look similar to the following: ‘.’ = clear field;

‘_’ = go to previous field;

boot device : nce processor number : 0 host name : nc file name : flash inet on ethernet (e) : 141.186.50.10 inet on backplane (b) : host inet (h) : gateway inet (g) : _

^D = quit

150.22.14.31:0xffffff00

When your network has subnets: If your network is subneted and if there is a router between the 6224 and the host computer(s) that it is to communicate with, enter the IP address of that router at the gateway inet line. Type the IP address of the router at the current cursor position on that line. When your network does not use subnets: If your network is not subneted or if there is not a router that the 6224 must go through to get to the host(s) (they are on the same subnet) do not enter anything at the gateway inet line.

Flags Repeatedly press the [Enter] key until the line flags appears on the PC display. A screen similar to the following should appear: ‘.’ = clear field;

‘_’ = go to previous field;

^D = quit boot device : nce processor number : 0 host name : nc file name : flash inet on ethernet (e) : 141.186.50.10 150.22.14.31:0xffffff00 inet on backplane (b) : host inet (h) : gateway inet (g) : user (u) ftp password (pw) (blank = use rsh): lxe302 flags (f) : 0x840 _ If the flags value is not 0x1800 type that value at the cursor position. This is the last boot parameter that might require modification.

E-SW-6224RG-F-ARC