Page 11

Chapter 1 Introduction

System Overview This manual is designed to familiarize the user with the LXE 6224 Session Manager device and the software resident in the 6224 – the commands that are specific to a 6224 running in an ANSI or LDS system are presented separately from those commands used with a 6224 running in an IBM system. All other information, if not noted as belonging to one system or the other, is common to all three host systems.

The LXE 6224 Session Manager provides host session management for the 2.4 Giga Hertz (2.4 GHz) RF data collection systems. It can be programmed to either maintain or sever a session between single or multiple hosts and LXE DOS computers (PCs or RF PCs) that use 2.4GHz Spread Spectrum radio transceivers for wireless communication. LXE offers three separate 6224 host configurations: one for use with an ANSI, LDS or IBM host. The differences between the systems are: •

Autologin is carried out from a mobile or desktop computer in the IBM and LDS versions; it is carried out in the 6224 Session Manager for ANSI applications.

•

The ANSI or LDS 6224 uses secondary terminal IDs, the IBM version 6224 Session Manager uses the terminal's IP address.

The 6224 Session Manager parameters can be setup using: •

A local method (required for initial setups) -- a dumb terminal, which is a personal computer (PC) running a terminal emulation program e.g. Procomm or HyperTerminal, connected to the 6224 via null modem cable (or equivalent).

•

A remote method -- after a valid IP address is assigned to the 6224, most setup commands can be entered using Telnet and the 6224 Session Manager shell.

Session Managers Session Managers -- ANSI and IBM are session oriented – LDS is not. Session oriented protocols are usually ANSI/Telnet and SNA (IBM). An LDS session only lasts for as long as it takes a message to originate from a remote terminal, pass to the host, and receive the host's response. While LDS RF PCs communicate with the LDS host using a common socket between the controller and the host, other RF PCs (e.g. ANSI, IBM) communicate with their hosts using individual socket connections with their hosts through the 6224. The purpose of the ANSI/IBM session manager is to maintain these individual socket connections even if the RF PC to session manager's connection is broken to the host for all RF PCs. These individual socket connections are broken only on command. Since LDS uses a common socket connection for all RF PCs, the host to controller socket connection is normally never broken, no matter the state of the RF PC's connection with the controller.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 12

2

Features

Features Note:

The 6224 Session Manager does not have an antenna. It is connected to the RF network (i.e. access points) by Ethernet cables.

The main features of the LXE 6224 Session Manager product are: •

ANSI/IBM only -- Establishes initial sessions between individual hosts and/or a single default host and individual RF PCs (radio frequency personal computers) and/or a group of RF PCs. The session manager can be set up to initially establish a session between individual hosts and/or a single default host and individual RF PCs and/or a group of terminals. If desired and programmed accordingly, a particular PC-host session will be maintained even if RF contact with the PC is interrupted. Note that for LDS 6224, the 6224 to host link, once made, is rarely severed.

•

ANSI/IBM only -- Maintains current session during PC absence and reconnection. The session manager can maintain the current session while the RF PC is absent and reconnects the returning PC’s connection to the maintained host session. If the 6224 is set up to maintain a session, the RF PC resumes host communication when RF contact is reestablished as though it had not been interrupted. The 6224 Session Manager is capable of establishing and maintaining up to 128 PC-host connections. 128 sockets are available for up to 128 RF PC/host connections. Note that in LDS 6224 the link to the host always remains even when the RF PC is absent. The presence of RF PCs is not required for the establishment of the LDS 6224 to host link.

•

Remote Telnet access security feature. Also included is a security feature which can be programmed to restrict remote Telnet access to the 6224 setup parameters. This feature allows remote access to the setup routines only to privileged individuals with the correct User Name and Password.

ANSI Only •

Login script utility. In addition to managing sessions, utilities are included for programming Login scripts for automatically logging-in the RF PC(s) to the host(s). The scripts can be programmed to connect a group of PCs to one single host or individual PCs to their own individual host or a mixture of the choices.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 13

In This Guide

3

In This Guide The purpose of this guide is to provide information and procedures on installing and using the 6224 Session Manager. Chapter 1 “Introduction” describes the functionality of the LXE 6224 Session Manager system and includes the quick-start instructions in “Getting Started.” Also included are manuals and accessories for the 6224, available from LXE. Chapter 2 “Hardware Configuration” contains the 6224 hardware description and installation instructions for Ethernet and power cabling requirements. Chapter 3 “Software Configuration” describes the Session Manager software and commands and includes instructions on using the software. Chapter 4 “Opening a Remote Session” describes the ANSI, LDS Telnet login and the IBM login process. It also includes the list of, and explains, login commands. Chapter 5 “Technical Specifications” provides physical dimensions and performance information of the 6224 Session Manager.

Document Conventions This Reference Guide uses the following document conventions: ALL CAPS

All caps are used to represent disk directories, file names, and application names.

“Quotes”

Indicates the title of a chapter or a section, subject, topic, element or point within a chapter, for example, “Document Conventions”.

[Brackets]

Indicates a key on the keyboard, for example, [Ctrl]. Indicates a reference to another book, chapter or section.

Note:

Keyword that indicates immediately relevant information.

Warning:

Keyword and icon that indicates a warning message to follow.

Attention:

Keyword that indicates vital or pivotal information to follow.

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 14

4

Quick Start

Quick Start These instructions are abbreviated and give a general outline of the steps to be performed when setting up a new 6224. Detailed procedures are provided in Chapter 3 “Software Configuration.” Note:

Program a valid IP Address in the 6224 before connecting it to the network.

Connect a “dumb terminal” (a personal computer running a terminal emulation program e.g. Procomm or HyperLink) to the Console port. 1.

Connect the power cord to a reliable electric power source and then to the 6224 power outlet.

2.

Turn the 6224 on. Press the Enter key on the PC before the autoboot countdown reaches zero.

3.

Assign an IP address to the 6224. Assign, if needed, subnet mask, gateway address and flag values. Press [Ctrl] [x] to continue the autoboot process.

4.

When autoboot process is complete, connect the 6224 to the network. Continue setting or viewing programming parameters.

5.

Save the setup information.

6.

Disconnect the PC from the 6224 when the 6224 Session Manager programming is complete.

Note:

The lithium backup battery in the 6224 should be tested periodically and replaced when necessary.

Remember: In order to communicate with the LXE 6224, the LXE RF Computers must have access to the Ethernet network. The LXE Access Point provides that access. Currently LXE offers several families of access points; the 6400, 6500 and 6700 series. Your reference is directed to the specific manual(s) for the family of access points used in your RF Data Collection System. The manual for the 6500 Access Point is “6520 Access Point Reference Guide.” Contact your LXE representative for availability of the 6400 Access Point manuals and those delivered with the Access Point. Note:

Manuals are included on the LXE Manuals CD (9000A426LXEMANUALS) and on the LXE website, www.lxe.com.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 15

Synopsis of Setup Procedure

5

Synopsis of Setup Procedure Note:

When working with a 6224 in an ANSI or LDS system, the on-screen text displayed for each terminal's address is "secondary ID". When working with a 6224 in an IBM system, the on-screen text displayed for each terminal's address is "IP address". See Chapter 2 “Hardware Configuration” section titled “Connect 6224 to PC” for instructions on local PC connection, via null modem cable (or equivalent), to a 6224.

Performed at LXE Prompt: 1.

The setup is begun by assigning and programming a unique IP address for the 6224 session manager and the inputting of a subnet mask, and gateway address if required. The flags value can also be checked and set, if necessary. Note:

If this is a "first time" setup of the 6224, the IP address, gateway, and net mask must be entered at the LXE prompt using a serial terminal connected to the console port of the 6224. Once the 6224 has been set up for a given network and can communicate over the network, it can be remotely administered using Telnet.

Performed at 6224 Prompt: A default “listen” port number of four thousand (4000) is assigned by the firmware but, it can be changed (either dumb terminal or Telnet) if required. The listen port is the port that the 6224 “listens” on for incoming traffic from the PCs. If you assign a different number to the listen port, do not select the number of a “well known” port (e.g., 23). Note:

If the system is ANSI or IBM, continue to the following section titled "ANSI and IBM" – if LDS, continue to the following section titled "LDS Only". The following commands are conducted at the 6224 prompt.

ANSI and IBM: 2.

Program the default host IP address and port number. The default host is the host that a PC will be connected to if an individual (different) host has not been preprogrammed for that particular PC(s).

3.

At this point, you will program whether ANSI or IBM sessions should remain connected if RF communication has been interrupted. When you elect to retain connections, if a host connection already exists for a PC that is attempting to reconnect, that PC will be reconnected to the existing host connection. A new connection is not established if the 6224 currently has a host connection active for a given RF PC ID. When you elect to not retain a connection, a currently active host connection for that RF PC is “closed” any time a given PC attempts to connect. This action forces a new connection to be established each time the RF PC attempts to connect.

4.

You might desire to have certain PCs connect to a host other than the “default” host (ANSI and IBM). You must add the identity of PC's to the individual terminal table indicating the desired host, IP address and port. You must indicate to the 6224 the addresses of those PCs plus the IP addresses and port numbers of the desired host for those PCs.

5.

In step 3. above, you indicated whether sessions should remain connected if RF

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 16

6

Synopsis of Setup Procedure communication is interrupted. In this portion of the setup you can indicate the terminal address of certain PCs that you wish to handle differently. Each entry in the individual terminal table can specify whether the terminal shall remain connected or not. 6.

ANSI Only: In this step, you will compose the individual auto login scripts for each of the RF PCs. These scripts must contain the “prompts” that the host sends for each PC and the “responses” that the 6224 must return to the host on behalf of the PC. A set of login scripts must be programmed for each RF PC.

7.

Set the watchdog parameters if desired.

LDS Only: 2.

Set the 6224 host connection mode. The 6224 LDS allows the choice of having the host act as the client and initiating the connection, or having the 6224 LDS act as the client and initiating the connection.

3.

If the 6224 is acting as client (i.e. the 6224 will contact the host), the host's IP address must be set.

4.

Set the host port number (if a value other than the default 5000 is wanted).

5.

Set the RF PC listen port (if a value other than the default 4000 is wanted).

6.

Set the watchdog parameters.

6224 Session Manager Reference Guide

E-SW-6224RG-F-ARC

Page 17

Sequence of Events

7

Sequence of Events ANSI, IBM, LDS: The PC session management process is started when the PC “opens” a session with the 6224 Session Manager using its IP address and its "listen port". ANSI and IBM Only: The 6224 checks for an existing host connection for this PC. If session management is enabled and a connection to the host already exists, the incoming connection is joined to the existing host connection. If session management is disabled or a host connection does not already exist for the PC’s address, the 6224 opens a session with the host and routes traffic from the incoming connection to this host socket. Sessions may be taken down at the host's request or on command at the 6224 console. In some cases, a session may also be terminated from the PC. LDS Only: The 6224's connection to the host is independent of the state of the RF PC connection.

With Telnet Security When the Telnet Security feature is properly configured and enabled, a Telnet session is performed as follows: 1.

From a Telnet capable computer, the user issues the “open” command to the IP address of the 6224 (port 23).

2.

The 6224 responds with a prompt requesting the entry of a login user name. At this point, the operator must enter the correct pre-programmed user name.

3.

The 6224 then prompts for entry of the pre-programmed password. The operator must enter the correct password.

4.

If either the user name or password is incorrect, access is denied.

5.

When the correct user name and password have been entered, the 6224 responds with the operating system shell prompt: -> With the shell prompt available, most of the setup parameters of the 6224 can be observed and/or modified. Note: The IP address of the 6224, subnet mask, gateway address or the flags value cannot be viewed or modified via Telnet. Those four parameters can only be accessed by the “local” configuration method where a PC is directly connected to the Console connector at the rear panel of the 6224.

6.

To break (close) the Telnet connection with the 6224, type the following command at the operating system shell prompt: ->logout

E-SW-6224RG-F-ARC

6224 Session Manager Reference Guide

Page 18

8

Getting Help

Getting Help All LXE manuals are now available on one CD and they can also be viewed/downloaded from the LXE ServicePass website. Contact your LXE representative to obtain the LXE Manuals CD. You can also get help from LXE by calling the telephone numbers listed on the LXE Manuals CD, in the file titled "Contacting LXE". This information is also available on the LXE website’s ServicePass page. Explanations of terms and acronyms used in this manual are located in the file titled "LXE Technical Glossary" on the LXE Manuals CD.

Manuals Note:

The manuals are located on the LXE Manuals CD and on the LXE ServicePass website.

1380 Reference Guide (DOS Computer) 1390 Reference Guide (DOS Computer) 2325 Reference Guide (DOS Computer) 6200 Network Management Guide (Legacy) ANSI Plus Programmer's Guide (TE Software) LDS Plus Programmer's Guide (TE Software) MX1 Reference Guide (DOS Computer) MX2 Reference Guide (DOS Computer) MX3 Reference Guide (DOS Computer) TN3270 Terminal Reference Guide (TE Software) TN5250 Terminal Reference Guide (TE Software) VX1 Reference Guide (DOS Computer) VX2 Reference Guide (DOS Computer) VX4 Reference Guide (DOS Computer)

Accessories Cable, Null Modem DA-9F to DB-25, 6 ft PCMCIA SRAM Card, 1MB Software, 6224 Session Manager

6224 Session Manager Reference Guide

9000A052CBL6D9D25 9000A101PCC1SRAM Contact LXE

E-SW-6224RG-F-ARC