Manual · Keyence
General Purpose Digital Laser Sensor LV Series Instruction Manual
Manual10 pagesPDF 11 MB
Instruction manual for the Keyence LV Series digital laser sensors, including the LV-21A amplifier: wiring, mounting, setup and specs.
Covers · 1 model
The models it covers
Summary
What is in it
The instruction manual for Keyence's LV Series general purpose digital laser sensors, covering amplifier units such as the LV-21A, LV-21AP, LV-22A and LV-20A and their sensor heads. It gives laser safety information, part names and accessories, the input/output circuit diagram, mounting the amplifiers and sensor head, sensitivity adjustment, display and mode settings, initial reset, error messages, key lock, external tuning, mutual interference suppression, interrupting laser radiation, the specifications and hints on correct use.
Its parts
- Safety Information for LV Series
- Part Names
- Accessories
- Input/Output Circuit Diagram
- Mounting Amplifiers
- Mounting the Sensor Head
- Sensitivity Adjustment
- Mode Setting
- Initializing Settings (Initial Reset)
- Error Messages
- Adjusting Sensitivity via External Signals (External Tuning)
- Mutual Interference Suppression
- Interruption of Laser Radiation
- Specifications
- Hints on Correct Use
From the manual
Key facts from this manual
Each line names its page in the PDF.
Keyence instruction manual for the LV Series digital laser sensors. It covers the amplifier units LV-21A, LV-22A, LV-20A, LV-11A, LV-51M and LV-52 with their PNP versions (LV-21AP, LV-22AP, LV-51MP, LV-52P), and the LV-H sensor heads. It shows how to mount and wire the amplifiers, tune sensitivity, set modes and read the error messages.
- Type
- LV-21A: main amplifier unit for LV Series laser sensor heads p. 4, 8
- Power supply
- 12 to 24 VDC ±10% max., ripple (P-P) 10% max.; expansion units take power from the main unit p. 8
- Control outputs
- Open-collector, 2 channels: NPN max. 100 mA (40 V max.); PNP max. 100 mA (30 V max.) p. 8
- Expansion units
- Main units LV-11A/21A/51M: up to 7 of LV-22A, LV-52, AP-V42, or up to 14 of FS-T2/M2/V12/V22/PS-T2/ES-M2 p. 4
- Detection modes
- STANDARD 1, STANDARD 2, UP edge, DOWN edge, set separately for channels A and B p. 8
- Timer
- OFF DELAY, ON DELAY or ONE SHOT, 1 to 9999 ms, set per channel p. 8
- External inputs
- Laser emission stop (main unit only) and external tuning, each at least 20 ms; LV-51M/51MP have no external tuning p. 8
- Interference suppression
- Units allowed side by side: FINE not possible, TURBO 2, SUPER 4 (main plus expansion units) p. 8
- Display
- Digital LED monitor (light intensity and setting), bar LED monitor, laser ON alarm indicator, 2 output indicators p. 8
- Operating temperature
- -10 to +55 °C (14 to 131 °F), no freezing; humidity 35 to 85%, no condensation p. 8
- Compatible sensor heads
- LV-21A/22A/20A/21AP/22AP: LV-H32, H35, H37, H42, H47, H52, H62 and H67 among others p. 9
- Spare head connector
- OP-27934, needed once a connector has been fitted twice p. 4
- Material
- Polycarbonate main body and cover p. 8
What this manual walks you through
- Wiring the amplifier inputs and outputs p. 3
- Mounting amplifiers on a DIN rail and adding expansion units p. 4
- Shortening the sensor head cable and refitting its connector p. 4
- Setting sensitivity by two-point, maximum, automatic or positioning tuning p. 5
- Choosing power mode, detection mode, display shift, hold and timer p. 6
- Resetting all settings to factory defaults p. 7
- Locking the operation buttons p. 7
- Tuning from a switch or PLC (external tuning) p. 7
- Stopping the laser with an external signal p. 8
- Sensor head specifications p. 9
Good to know
- Mutual interference suppression does not work between two main units. p. 8
- Turn the power off before connecting or disconnecting amplifiers, and always use a DIN rail and end unit for several amplifiers. p. 4
- With more units connected the allowed ambient temperature drops: up to +50 °C with 2 to 5 units, +45 °C with 6 to 7. p. 8
- Amplifier cable extensions need at least 0.3 mm2 wire and must not exceed 100 m. p. 10
- Do not use the LV Series outdoors or where outside light can shine straight into the receiver. p. 10
Questions this manual answers
What does the brK error mean on a Keyence LV amplifier?
The sensor head is not connected, is plugged into the wrong connector, or its cable has an open circuit. p. 7
How do I reset an LV-21A to factory settings?
With the received light intensity display showing and the buttons unlocked, press S five times while holding M, then press S once to confirm. p. 7
How many expansion units can be added to an LV-21A?
Up to 7 LV-22A, LV-52 or AP-V42 units, or up to 14 FS-T2/M2/V12/V22/PS-T2/ES-M2 units. p. 4
How does external tuning work on the LV-21A?
Lock the buttons and wire the pink cable to a switch or PLC; shorting pink to blue for at least 20 ms acts like pressing S. p. 7
Contents
Chapters and sections
Each line opens the PDF at its page.
- Safety Information for LV Series1
- Part Names2
- Accessories2
- Input/Output Circuit Diagram3
- Mounting Amplifiers4
- Mounting the Sensor Head4
- Sensitivity Adjustment5
- Differentiation Mode (page 6)5
- Fine Adjustment of Setting Values5
- Selecting Display Modes5
- Mode Setting6
- Initializing Settings (Initial Reset)7
- Error Messages7
- Selecting Channels7
- Selecting Output Mode7
- Key Lock7
- Adjusting Sensitivity via External Signals (External Tuning)7
- Caution on usage of QL (LV-20A only)8
- Mutual Interference Suppression8
- Interruption of Laser Radiation8
- Specifications8
- Specifications9
- Hints on Correct Use10
- Cautions on Usage the LV-H100/H110/H30010
- WARRANTIES AND DISCLAIMERS10