Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Keyence LV-21 Spec Sheet

Spec sheet · Keyence

Keyence LV-21 Spec Sheet

Spec sheet3 pagesPDF 1.3 MB

All 3 pages are below, each with its text.

Download the PDF1.3 MB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Keyence data sheet for the LV-21A, the NPN main amplifier unit of the LV series laser sensors. It lists response speeds, the two control outputs, power, expansion limits and the operating environment, then gives a dimensions page and the NPN input and output wiring diagram.

Type
Amplifier unit, main unit, NPN p. 1
Control output
NPN open-collector, 2 channels, 40 VDC max., 100 mA max., residual voltage 1.0 V max. p. 1
Power supply
12 to 24 VDC, ripple (P-P) 10% max. p. 1
Power consumption
1.5 W max. (125 mA max. at 12 V, 62.5 mA max. at 24 V) p. 1
Response speed
FINE 80 μs, TURBO 500 μs, SUPER TURBO 4 ms p. 1
Operating temperature
-10 to +55 C (14 to 131 F), no condensation p. 1
Expansion units
Up to 7 expansion units (8 units including the main unit) p. 1
Interference prevention
FINE none, TURBO 2 units, SUPER 4 units p. 1
Protection circuit
Reverse polarity, overcurrent and surge absorption p. 1
Humidity
35% to 85% RH, no condensation p. 1
Material
Polycarbonate main body and cover p. 1
Weight
Approx. 120 g p. 1

What this sheet walks you through

  • Outline dimensions of the amplifier unit p. 2
  • Wiring the NPN inputs and outputs, including laser radiation interruption and external calibration inputs p. 3

Good to know

  • Several units connected together must be mounted on a metal DIN rail, with output current of 20 mA max. p. 1
  • The allowed ambient temperature drops as expansion units are added: up to +50 C with 2 to 5 added, up to +45 C with 6 or 7. p. 1
  • The laser radiation interruption input is on the main unit only. p. 3

Questions this sheet answers

What power supply does the Keyence LV-21A need?

12 to 24 VDC with ripple of 10% max.; it draws 1.5 W max. p. 1

How many expansion units can be added to the LV-21A?

Up to 7 expansion units, for 8 units in all including the main unit. p. 1

What outputs does the LV-21A have?

Two NPN open-collector control outputs, rated 40 VDC and 100 mA max. p. 1

What is the response time of the LV-21A?

80 μs in FINE mode, 500 μs in TURBO and 4 ms in SUPER TURBO. p. 1

The file

Size and text

Pages3
PDF1.3 MB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Keyence LV-21 Spec Sheet

The text of page 1, from the PDF itself

Data Sheet LV­21A Amplifier Unit, Main Unit, NPN

SPECIFICATIONS Model

LV­21A

Main unit / Expansion unit

Main unit

Response speed

FINE: 80 μs/ TURBO: 500 μs/ SUPER TURBO: 4 ms

Control output

NPN open­collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

Protection circuit

Reverse polarity protection, overcurrent protection, surge absorption

Expansion of units

Up to 7 additional expansion units can be installed (8 units including the main unit),

Number of interference preventive units*1

FINE:None、TURBO:2 units、SUPER:4 units

Ratings

Power supply voltage

12 to 24 VDC ripple (P­P) 10% max.

Power consumption

1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

Ambient temperature used

­10 to +55˚C (14 to 131˚F), No condensation *2

Ambient humidity used

35% to 85% RH, No condensation

Material

Main body, cover: Polycarbonate

Weight

Approx. 120 g

*1 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as

follows: *2 When 2 to 5 expansion units are additionally installed: ­10 to +50˚C (14 to 122˚F). When 6 or 7 expansion units are additionally installed: ­10 to +45˚C (­14 to +113˚F).

KEYENCE AMERICA 1­888­KEYENCE(Toll Free)

http://www.keyence.com/

2014/01/18 Page:1/3

Page 2 of Keyence LV-21 Spec Sheet

The text of page 2, from the PDF itself

Data Sheet Dimensions

KEYENCE AMERICA 1­888­KEYENCE(Toll Free)

http://www.keyence.com/

2014/01/18 Page:2/3

Page 3 of Keyence LV-21 Spec Sheet

The text of page 3, from the PDF itself

Data Sheet I/O Circuit Connection diagram NPN

  • Orange (monitor output) only for LV­51M

Laser radiation interruption (main unit only) External calibration input NPN

KEYENCE AMERICA 1­888­KEYENCE(Toll Free)

http://www.keyence.com/

2014/01/18 Page:3/3