For the Keyence LV-21

Page 9

Specifications Sensor head specifications 1 Model

LV-H32

Light source Laser Class

LV-H35 LV-H37 LV-H42 LV-H47 LV-H52 LV-H62 Visible red semiconductor laser, Wavelength: 660 nm, Output: 3.0mW(FDA), 1.0mW(IEC), Pulse duration: 3.5 μs

FDA (CDRH) Part1040.10

Class II Laser Product Class 2 Laser Product LV-21A / 22A / 20A / 21AP / 22AP

IEC60825-1 Supported amplifier unit

Detection distance

FINE

30 to 250 mm

150 mm

TURBO

30 to 500 mm

300 mm

SUPER

30 to 1000 mm

600 mm

Detection distance max.300 mm Spot diameter: 0.8 mm max.

approx. Ø2 mm

Beam spot shape

250 mm (Slit black: 150 mm) (Slit gray: 100 mm) 500 mm (Slit black: 300 mm) (Slit gray: 200 mm)

70±15 mm

Ambient illumination

55 to 85 m

1000 mm (Slit black: 600 mm) (Slit gray: 400 mm)

15 to 240 mm (Slit: 20 to 100 mm)

2m

20 m

5m

30 m

7m

30m (When OP-42198 is used: 50 m)

Detection distance 150 mm Detection distance <Typical>*1 Area width: approx. 37mm 35 mm approx. Ø1.5 mm 20 m approx. Ø50 μm approx. 21 mm (Slit black: approx. 19 mm) Area width: (Distance 1 m approx.10x3 cm (distance 70 mm) (distance 70 mm) (Slit gray: approx. 7 mm) approx. 25 mm max) 30 m Thickness: 1 mm max. (Slit: approx.9 mm) approx.15x4 cm

-10 to +55°C (14 to 131°F), No freezing 35 to 85%, No condensation

Environmental Ambient temperature resistance Relative humidity

10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions: 2 hours per direction Glass-reinforced resin

Vibration resistance Case Lens (cover)

15 to 120 mm (Slit: 20 to 60 mm) 15 to 180 mm (Slit: 20 to 80 mm)

Laser ON alarm indicator: green LED, Level indicator: green x 2, red x 1 (level indicator displays excess gain from 90 to 110%) Incandescent light: 10,000 lx max. Sunlight: 20,000 lx max.

Indicator

Materials

LV-H67

Transmitter: Acrylic Transmitter: Glass Norbornene resin Receiver: Polyarylate Receiver: Polyarylate

Polyarylate

Transmitter: Glass Receiver: Polyarylate

-

Others

Polyarylate

Norbornene resin

Slit: Polyacetal

Reflector: Acrylic, Polycarbonate

2m

Cable length approx. 45 g

Weight (including cable)

approx. 55 g approx. 45 g

Sensor head specifications 2 Model Light source

Laser Class

FDA (CDRH) Part1040.10

IEC60825-1 Supported amplifier unit FINE Detection distance

LV-H64

LV-H65

LV-H41

LV-H51

LV-H35F

LV-H62F

LV-H100

Visible red semiconductor laser Invisible infrared semiconductor laser Invisible infrared semiconductor laser Wavelength: 660 nm Wavelength: 785 nm Wavelength: 660 nm Output: 3.0mW(FDA), 1.0mW(IEC) Output: 2.5mW(FDA), 0.3mW(IEC) Output: 3.0mW(FDA), 1.5mW(IEC) Pulse duration: 3.5 μs Pulse duration: 3.5 μs Pulse duration: 3.5 μs

TURBO

SUPER

Beam spot shape

Class II Laser Product

Class I Laser Product

Class 2 Laser Product LV-21A / 22A / 20A / 21AP / 22AP

Class 1 Laser Product LV-11A

LV-H110

LV-H300

Visible red semiconductor laser Wavelength: 660 nm Output: 3.0mW(FDA), 1.0mW(IEC) Pulse duration: 3.5 μs

Class II Laser Product Class 2 Laser Product LV-21A / 22A / 20A / 21AP / 22AP LV-51M / 52 / 51MP / 52P

100 to 500 mm 100 mm 250 mm 15 to 120 mm (When OP-51428 is (When OP-51428 is (Slit black: 150 mm) (Slit: 20 to 60 mm) used: 100 to 700 mm) used: 150 mm) (Slit gray: 100 mm) 500 mm 200 to 850 mm 10 to 150 mm 15 to 180 mm (When OP-51428 is (When OP-51428 is (Slit black: 300 mm) (Slit: 20 to 80 mm) used: 300 to 1000 mm) used: 10 to 250 mm) (Slit gray: 200 mm) 400 to 1200 mm 100 to 200 mm 1000 mm 15 to 240 mm (When OP-51428 is (When OP-51428 is (Slit black: 600 mm) (Slit: 20 to 100 mm) used: 600 to 1500 mm) used: 150 to 350 mm) (Slit gray: 400 mm) Detection distance150 mm Area width: approx. Detection distance 38 mm 35 mm Area width: Area width: 40 mm Area width: 50 mm (Slit black: approx.1 9 mm) approx. (Distance 300 mm) (Distance 100 mm) (Slit gray: approx. 25 mm(Slit: 7 mm) approx. 9 mm) Thickness: 1.3 mm max

100 mm

1.5 m

200 mm

3.5 m

450 mm

5m approx. Ø2 mm approx. Ø1.5 mm (Distance 1 m max)

2000 mm (Detection width 10 mm)

2000 mm (Detection width 30 mm)

Area width approx. 12 mm

Area width approx. 32 mm

Laser ON alarm indicator, Power indicator*2: green LED, Level indicator: green x 2, red x 1 (level indicator displays excess gain from 90 to 110%)

Indicator Ambient illumination Environmental Ambient temperature resistance Vibration resistance Case

Incandescent light; 10,000 lx max. Sunlight: 20,000 lx max. -10 to +55°C (14 to 131°F), No freezing 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions: 2 hours per direction Glass-reinforced resin Fluoroplastic (PFA) Glass-reinforced resin

Lens (cover)

Norbornene resin

Others

Reflector: Acrylic, Polycarbonate

Slit: Polyacetal

O-ring: Fluororubber approx. 45 g approx. 55 g approx. 80 g

Materials

Cable length*4 Weight (including cable)

Polyarylate

Glass O-ring: Fluororubber Reflector: Glass, Fluoroplastic (PFA), Fluororubber

Transmitter: Glass, Receiver: Polyarylate -

2m approx. 100 g approx. 80 g approx. 100 g

*1 Beam spots may appear outside the beam spot due to stray light. *2 The power indicator is installed only in the receiver of the LV-H100/H110/H300. *3 The LV-H35F/H62F enclosure rating is IP67. *4 The LV-H35F/H62F cable minimum bend radius is 25 mm.

9

LV Series-IM_E

Page 10

Hints on Correct Use

WARRANTIES AND DISCLAIMERS (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/ Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.

• To extend the amplifier cable length, use a cable that has a crosssectional area of at last 0.3 mm2. Limit the length of cable extensions to 100 m. (For further information on connecting several units contact KEYENCE) • Placing the amplifier cable together in the same conduit with power lines or high voltage lines may cause detection errors due to interference or sensor damage. For this reason, always isolate the amplifier cable from these lines. • If using a commercial switching regulator, make sure to ground both the frame ground terminal and ground terminal. • Do not use the LV Series outdoors, or in any location where extraneous light can directly enter the light receiving surface. • At the maximum sensitivity setting, detection distance may vary somewhat due to slight differences in the characteristics of individual units. • Improper wiring may cause the amplifier to become hot or alter sensitivity. (Input/ Output Circuit Diagram: page 7) • Do not use connectors for sensor head-to-amplifier connections more than 100 times. • Displayed values may vary due to surrounding conditions (e.g. temperature changes, dust) Cautions on using the LV-H62/H62F/H67 • Use FINE mode when there are any white or mirror-surfaced objects near the sensor head. • When the output is unstable in standard 1 mode (Std), change the detection mode to standard 2 (Std2). Reflector • The values on the received light intensity display may vary depending on the surface condition of the reflector.

Cautions on Usage the LV-H100/H110/H300 • Use the exclusive bracket (optional LV-B101, LV-B102, LV-B301, LV-B302) to mount the sensor. Adjust the light axis of the transmitter and receiver in both the vertical and horizontal directions without any target in the detection area. Then, mount the sensor while maximizing the value displayed on the amplifier. (Adjust the light axis so that the transmitter beam is at the center of the receiver block) • When mounting the sensor, mount the transmitter and receiver so that their sides on which the indicator is mounted face the same direction. The side on which the indicator is mounted

The side on which the indicator is mounted

BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples. E 1101-3

The side on which the indicator is mounted

The side on which the indicator is mounted

Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved. 11626E 1043-3 96M11626 Printed in Japan

LV Series-IM_E

10