Page 31

Chapter 3

Mode Selection

Typical applications Detecting missing products in a packaging process

Measuring paper sheet width

3 AREA

Determines if there are any products missing in each carton.

Measuring lead pitch

PITCH

Inspects the bend in IC leads.

Detecting missing balls of bearings

COUNT

Counts the number of balls to determine if any are missing.

OUTER

Measures the width of a paper sheet with two cameras after the slitting process.

Detecting missing cables

EDGE NO

Counts the number of cables wired to connectors.

Lighting inspection of an LCD

POINT

Inspects unlit segments of LCD displays.

21

Page 32

Chapter 3

Mode Selection Detecting the stains or pinholes on sheet material

3 STAIN

Tips

Detects any stains or pinholes on sheet material.

Detecting the center of gravity of alignment marks

GRAVITY

Detects the center of gravity of alignment marks.

Unit Conversion Function The CV-701(P)/751(P) processes an image and obtains data with the number of pixels. For example, measuring a target with an outer size of 3.25 mm may give 65.0 pixels. The unit conversion function converts the number of pixels into other units such as mm. 65.0 3.25 ➮ See page 137. x0.05

3.1.3

“INS+POS” (Inspection + position) Use the “INS+POS” mode to adjust the position and angle of the window. Use this mode for trigger detection when the “INS/TRG” mode can’t be used because the position of the target is not constant. ➮

See “4.6 “INS” Mode Basic Settings” on page 70 and “4.9 “Position Detection” Mode Basic Settings” on page 109 for the setting procedure.

■ Position adjustment Use this function when detection cannot be operated at the same position in a window because the position of a target is not constant in field operation. Using the position adjustment function allows the inspection window to adhere to the motion of targets. The position adjustment, like the “ABS.POS” mode, uses either “pattern search” or “edge detection” to recognize the distinctive image and edge of a target. It then adjusts the inspection window to adhere to the target. This function allows the CV-701(P)/751(P) to constantly detect the same position of targets regardless of the movement of targets. Also, the rotation adjustment function allows the CV701(P)/751(P) to automatically tilt the inspection window when the target makes a rotating movement.

REG SCR (Registered screen) Inspection window (Edge pitch)

With position adjustment

PROG

PROG

PROG

WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000

WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000

WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000

T=000017

T=000017 RAW SCRN ●

T=000017 RAW SCRN ●

Position adjustment ●RAW SCRN window

22

Without position adjustment

Page 33

Chapter 3

Mode Selection

Functions • • •

Inspects every trigger input. Inspection functions are similar to those of “INS/TRG” mode. The position adjustment function is the same as “ABS.POS”.

Typical applications Use this mode when the position of a target is not constant for applications described in the “INS/TRG” section. ➮ See page 21.

3.1.4

“ABS.POS” (Absolute position) Use the “ABS.POS” mode to detect the position and angle of the target, and judge the result with the position adjustment function. ➮ See “4.9 “Position Detection” Mode Basic Settings” on page 109 for the setting procedures.

Functions • • • • •

Detects the position and angle of a target. “Pattern search” and “edge detection” can be selected for the measurement mode. Detects up to four windows, which can be drawn to measure the position of four points simultaneously. The judgment, coordinates, angle, and correlation ratio can be output. The camera can be set to trigger mode only.

■ Position detection method Pattern Search Register a screen as a reference that includes the position of the pattern to be searched, and save the pattern to the pattern window. The saved pattern window is searched through the arbitrary-set search window from the upper-left corner to the lower-right corner for the position of the most similar pattern. Reference image

Registered image

Search

Detection

Pattern window Search window

23

3

Page 34

Chapter 3

Mode Selection Edge Detection Register a screen as a reference that includes the position of the pattern to be searched, and register an X window and Y window as illustrated. The windows are searched for points to show a change in color to be recognized as the edge, and then the X- and Y- coordinates of the edge are detected. Position detection of the X-coordinate alone using the X window is also available. Y window Edge

3

PROG

PROG

WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000

WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000

T=000017 RAW SCRN ●

T=000017 RAW SCRN ●

X-window Edge

Typical application Detecting the misalignment of an IC chip to lead frames

Positioning of a PC board

Controlling robotic handling

Positioning of glass substrate

Presswork

24

Page 35

Chapter 3

3.1.5

Mode Selection

“REL.POS” Mode Use the “REL.POS” mode to detect the position and angle of two or more targets, and judge the result with the position adjustment function. ➮ See “4.9 “Position Detection” Mode Basic Settings” on page 109 for the setting procedures.

Functions • • • •

• •

Detects the position of two of more targets, measures the distance between the two points, and judges the result. “Pattern search” and “edge detection” can be selected for the measurement mode. The relative distance between up to three measurement windows and one reference window can be measured simultaneously. The positions of the search window, pattern window (when pattern search is used), and X/Y windows (when edge search is used) are adjusted (X, Y, and θ) according to the detection result of the reference window position. The judgment, coordinates, angle, and correlation ratio can be output. The camera can be set to trigger mode only.

Y-coordinate

X-coordinate

Typical applications Detecting misaligned labels and loose caps

Detecting the relative position of a PC board and IC

Detects simultaneously the position and angle of labels and loose caps.

Detects the correlation between the edge of a PC board and IC

25

3

Page 36

Chapter 3

Mode Selection Detecting electrodes of lithium-ion batteries

Detecting the molding position of laminated film

Detects the position of an electrode using the edge of the battery as the reference.

Detects the molding and width of laminated films using two X-edges.

3

Tips

Use “REL.POS” mode to measure the relative position of [REF WND] and [REL 1/2/3]. Use “REF WIND” to detect the rotation angle. “WIND1/2/3” will be tilted by the amount of the angle deviation for detection.

WIND2 REF WIND

“WIND2” rotates in conjunction with “REF WIND”.

Use [REL.POS] mode to measure the relative position of [REF WND] and [REL_1/2/3].

26

Page 37

Chapter 3

Mode Selection

3.2 Selecting the Measurement Mode by Application Inspection items and checkpoints are listed below. Refer to the following chart to select the measurement mode best suited for your application. Inspection item Presence/absence detection (e.g. stains, defects)

Check point

The target is a long sheet.

Measurement mode Continuous detection

ARE/CON

3 The target is an individual product.

Area detection (e.g. missing print)

The target position is constant.

The target position is not constant.

Position detection (e.g. misaligned labels)

The reference point is fixed.

Individual detection

No position adjustment

INS/TRG (AREA)

Position adjustment

INS+POS (AREA)

Absolute position

ABS.POS Select either pattern search or edge detection. ➮ See page 118.

The reference point is not fixed.

Relative position

REL.POS Select either pattern search or edge detection. ➮See page 124.

27

Page 38

Chapter 3

Mode Selection

Inspection item Dimensional measurement (e.g. bend in pins)

Check point

The target position is constant.

Measurement mode No position adjustment

INS/TRG Select from the following modes. ➮ See page 70 for details.

The target position is not constant.

Position adjustment

• OUTER • INNER • PITCH • GAP

INS+POS Select from the following modes.

3

➮ See page 106 for details.

• OUTER • INNER • PITCH • GAP

Angle detection (e.g. dial indication)

ABS.POS (Angle adjustment)

Edge counting (e.g. number of connector pins)

The target position is constant.

The target position is not constant.

28

No position adjustment

INS/TRG (EDGE NO)

Position adjustment

INS+POS (EDGE NO)

Page 39

Chapter 3 Inspection item Counting (e.g. number of bearing balls)

Check point

The target position is constant.

The target position is not constant.

Mode Selection

Measurement mode No position adjustment

Position adjustment

INS/TRG (COUNT)

INS+POS (COUNT)

3 Presence/absence of multiple points (e.g. lighting inspection of an LED)

The target position is constant.

The target position is not constant.

Presence/absence of defects or stains (e.g. black spot on resin caps)

The target position is constant.

The target position is not constant.

Gravity detection (e.g. alignment marks of a PC board)

The target position is constant.

The target position is not constant.

No position adjustment

Position adjustment

No position adjustment

Position adjustment

No position adjustment

Position adjustment

INS/TRG (POINT sensor)

INS+POS (POINT sensor)

INS/TRG (STAIN)

INS+POS (STAIN)

INS/TRG (GRAVITY)

INS+POS (GRAVITY)

29

Page 40

Chapter 3

Mode Selection

MEMO

3

30