Page 31
Chapter 3
Mode Selection
Typical applications Detecting missing products in a packaging process
Measuring paper sheet width
3 AREA
Determines if there are any products missing in each carton.
Measuring lead pitch
PITCH
Inspects the bend in IC leads.
Detecting missing balls of bearings
COUNT
Counts the number of balls to determine if any are missing.
OUTER
Measures the width of a paper sheet with two cameras after the slitting process.
Detecting missing cables
EDGE NO
Counts the number of cables wired to connectors.
Lighting inspection of an LCD
POINT
Inspects unlit segments of LCD displays.
21
Page 32
Chapter 3
Mode Selection Detecting the stains or pinholes on sheet material
3 STAIN
Tips
Detects any stains or pinholes on sheet material.
Detecting the center of gravity of alignment marks
GRAVITY
Detects the center of gravity of alignment marks.
Unit Conversion Function The CV-701(P)/751(P) processes an image and obtains data with the number of pixels. For example, measuring a target with an outer size of 3.25 mm may give 65.0 pixels. The unit conversion function converts the number of pixels into other units such as mm. 65.0 3.25 ➮ See page 137. x0.05
3.1.3
“INS+POS” (Inspection + position) Use the “INS+POS” mode to adjust the position and angle of the window. Use this mode for trigger detection when the “INS/TRG” mode can’t be used because the position of the target is not constant. ➮
See “4.6 “INS” Mode Basic Settings” on page 70 and “4.9 “Position Detection” Mode Basic Settings” on page 109 for the setting procedure.
■ Position adjustment Use this function when detection cannot be operated at the same position in a window because the position of a target is not constant in field operation. Using the position adjustment function allows the inspection window to adhere to the motion of targets. The position adjustment, like the “ABS.POS” mode, uses either “pattern search” or “edge detection” to recognize the distinctive image and edge of a target. It then adjusts the inspection window to adhere to the target. This function allows the CV-701(P)/751(P) to constantly detect the same position of targets regardless of the movement of targets. Also, the rotation adjustment function allows the CV701(P)/751(P) to automatically tilt the inspection window when the target makes a rotating movement.
REG SCR (Registered screen) Inspection window (Edge pitch)
With position adjustment
PROG
PROG
PROG
WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000
WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000
WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000
T=000017
T=000017 RAW SCRN ●
T=000017 RAW SCRN ●
Position adjustment ●RAW SCRN window
22
Without position adjustment
Page 33
Chapter 3
Mode Selection
Functions • • •
Inspects every trigger input. Inspection functions are similar to those of “INS/TRG” mode. The position adjustment function is the same as “ABS.POS”.
Typical applications Use this mode when the position of a target is not constant for applications described in the “INS/TRG” section. ➮ See page 21.
3.1.4
“ABS.POS” (Absolute position) Use the “ABS.POS” mode to detect the position and angle of the target, and judge the result with the position adjustment function. ➮ See “4.9 “Position Detection” Mode Basic Settings” on page 109 for the setting procedures.
Functions • • • • •
Detects the position and angle of a target. “Pattern search” and “edge detection” can be selected for the measurement mode. Detects up to four windows, which can be drawn to measure the position of four points simultaneously. The judgment, coordinates, angle, and correlation ratio can be output. The camera can be set to trigger mode only.
■ Position detection method Pattern Search Register a screen as a reference that includes the position of the pattern to be searched, and save the pattern to the pattern window. The saved pattern window is searched through the arbitrary-set search window from the upper-left corner to the lower-right corner for the position of the most similar pattern. Reference image
Registered image
Search
Detection
Pattern window Search window
23
3
Page 34
Chapter 3
Mode Selection Edge Detection Register a screen as a reference that includes the position of the pattern to be searched, and register an X window and Y window as illustrated. The windows are searched for points to show a change in color to be recognized as the edge, and then the X- and Y- coordinates of the edge are detected. Position detection of the X-coordinate alone using the X window is also available. Y window Edge
3
PROG
PROG
WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000
WINDOW 1 COLOR MEASURE 248,168 378,236 MASK – – –, – – – – – –, – – – DETECT MEASURE 001329 TOL H=000000 L=000000
T=000017 RAW SCRN ●
T=000017 RAW SCRN ●
X-window Edge
Typical application Detecting the misalignment of an IC chip to lead frames
Positioning of a PC board
Controlling robotic handling
Positioning of glass substrate
Presswork
24
Page 35
Chapter 3
3.1.5
Mode Selection
“REL.POS” Mode Use the “REL.POS” mode to detect the position and angle of two or more targets, and judge the result with the position adjustment function. ➮ See “4.9 “Position Detection” Mode Basic Settings” on page 109 for the setting procedures.
Functions • • • •
• •
Detects the position of two of more targets, measures the distance between the two points, and judges the result. “Pattern search” and “edge detection” can be selected for the measurement mode. The relative distance between up to three measurement windows and one reference window can be measured simultaneously. The positions of the search window, pattern window (when pattern search is used), and X/Y windows (when edge search is used) are adjusted (X, Y, and θ) according to the detection result of the reference window position. The judgment, coordinates, angle, and correlation ratio can be output. The camera can be set to trigger mode only.
Y-coordinate
X-coordinate
Typical applications Detecting misaligned labels and loose caps
Detecting the relative position of a PC board and IC
Detects simultaneously the position and angle of labels and loose caps.
Detects the correlation between the edge of a PC board and IC
25
3
Page 36
Chapter 3
Mode Selection Detecting electrodes of lithium-ion batteries
Detecting the molding position of laminated film
Detects the position of an electrode using the edge of the battery as the reference.
Detects the molding and width of laminated films using two X-edges.
3
Tips
Use “REL.POS” mode to measure the relative position of [REF WND] and [REL 1/2/3]. Use “REF WIND” to detect the rotation angle. “WIND1/2/3” will be tilted by the amount of the angle deviation for detection.
WIND2 REF WIND
“WIND2” rotates in conjunction with “REF WIND”.
Use [REL.POS] mode to measure the relative position of [REF WND] and [REL_1/2/3].
26
Page 37
Chapter 3
Mode Selection
3.2 Selecting the Measurement Mode by Application Inspection items and checkpoints are listed below. Refer to the following chart to select the measurement mode best suited for your application. Inspection item Presence/absence detection (e.g. stains, defects)
Check point
The target is a long sheet.
Measurement mode Continuous detection
ARE/CON
3 The target is an individual product.
Area detection (e.g. missing print)
The target position is constant.
The target position is not constant.
Position detection (e.g. misaligned labels)
The reference point is fixed.
Individual detection
No position adjustment
INS/TRG (AREA)
Position adjustment
INS+POS (AREA)
Absolute position
ABS.POS Select either pattern search or edge detection. ➮ See page 118.
The reference point is not fixed.
Relative position
REL.POS Select either pattern search or edge detection. ➮See page 124.
27
Page 38
Chapter 3
Mode Selection
Inspection item Dimensional measurement (e.g. bend in pins)
Check point
The target position is constant.
Measurement mode No position adjustment
INS/TRG Select from the following modes. ➮ See page 70 for details.
The target position is not constant.
Position adjustment
• OUTER • INNER • PITCH • GAP
INS+POS Select from the following modes.
3
➮ See page 106 for details.
• OUTER • INNER • PITCH • GAP
Angle detection (e.g. dial indication)
ABS.POS (Angle adjustment)
Edge counting (e.g. number of connector pins)
The target position is constant.
The target position is not constant.
28
No position adjustment
INS/TRG (EDGE NO)
Position adjustment
INS+POS (EDGE NO)
Page 39
Chapter 3 Inspection item Counting (e.g. number of bearing balls)
Check point
The target position is constant.
The target position is not constant.
Mode Selection
Measurement mode No position adjustment
Position adjustment
INS/TRG (COUNT)
INS+POS (COUNT)
3 Presence/absence of multiple points (e.g. lighting inspection of an LED)
The target position is constant.
The target position is not constant.
Presence/absence of defects or stains (e.g. black spot on resin caps)
The target position is constant.
The target position is not constant.
Gravity detection (e.g. alignment marks of a PC board)
The target position is constant.
The target position is not constant.
No position adjustment
Position adjustment
No position adjustment
Position adjustment
No position adjustment
Position adjustment
INS/TRG (POINT sensor)
INS+POS (POINT sensor)
INS/TRG (STAIN)
INS+POS (STAIN)
INS/TRG (GRAVITY)
INS+POS (GRAVITY)
29
Page 40
Chapter 3
Mode Selection
MEMO
3
30