Page 41
Chapter 4 Setting Procedure This section describes how to use the panel keys or the remote control console to set the CV-701(P)/751(P). It covers everything from basic settings to the advanced settings.
4.1
Names and Functions of Control Keys and Monitor Screen .......................................................................... 32
4.2
Preparations ......................................................................... 35
4.3
Basic Settings ...................................................................... 36
4.4
“AREA” Mode Basic Settings ............................................. 57
4.5
“AREA” Mode Advanced Settings ..................................... 65
4.6
“INS” Mode Basic Settings ................................................. 70
4.7
“INS” Mode Advanced Settings ......................................... 96
4.8
“INS+POS” Mode Basic Settings ..................................... 106
4.9
“Position Detection” Mode Basic Settings ..................... 109
4.10
“Position Detection” Advanced Settings ........................ 118
4.11
Optional Settings .............................................................. 134
4.12
Operation Check of the Setting Status ........................... 140
4.13
Initialization ....................................................................... 142
4.14
Input/Output Operation in PROGRAM Mode .................. 143
4.15
Environmental Settings .................................................... 144
Page 42
Chapter 4
Setting Procedure
4.1 Names and Functions of Control Keys and Monitor Screen Set each parameter using the panel keys or the remote control console.
4.1.1
Controller
Panel keys (CV-751(P)) [WINDOW] key
[SCREEN] key Press this key to select the screen type. The following five screen types appear sequentially: “RAW SCR” and “PROCES1/2/3/4”. ➮ See page 55 for details. [RUN/PROG] key Press this key to select either RUN or PROG mode. The mode switches with each press.
SCREEN WINDOW RUN PROG PROGRAM No.
4
[PROGRAM No.] keys Press these keys to change programs.
ESC
[ESC] key Press this key to exit each setting. ENT
[Cursor] keys Press these keys to move a cursor or change a preset value.
CLEAR TRIG POWER
[ENT] key Press this key to confirm a setting.
[TRIG] key Press this key to input a trigger signal. Hold the key down for at least 2 seconds for continuous trigger input. Press it again to cancel it.
▼
■ How to use the cursor keys The cursor keys include four keys: “▲, ▼, following purposes.
, and
▼
[CLEAR] key Press this key to clear the setting.
”. Use these keys for the
•
To enter the “TOL” (tolerance) value.
•
To move the arrow cursor on the monitor.
•
To change the size of a window or move a window.
•
To lock the panel key operation temporarily. (Hold down the“ and ”keys simultaneously for at least 2 seconds to lock the panel keys. Hold them down again for at least 2 seconds to cancel. Move up
Move left
Move right
Move down
32
▼
To move through menu items.
▼
•
Page 43
Chapter 4
Setting Procedure
Remote control console (CV-701(P)/751(P)) Tips
The remote control console is optional with the CV-751(P). (OP-30938)
[ENT] key Use this key to move the cursor or to confirm a setting. RUN PROG
ENT
ESCAPE
[ESCAPE] key Press this key to exit each setting.
SCREEN
TRIGGER
[TRIGGER] key Press this key to input a trigger signal. Hold this key down for at least 2 seconds for continuous trigger input. Press it again to cancel it.
CLEAR
[SCREEN] key Press this key to select a screen type. The following five screen types appear sequentially: “RAW SCR” and “PROCES1/2/ 3/4”.
[Mode selection slide switch] Slide this switch up or down to select either RUN or PROG mode.
POWER
4
[CLEAR] key Press this key to cancel the setting.
➮ See page 54 for details.
■ How to use the ENT key ● Press the center of the key • To select a menu item. • To confirm a setting. EN
T
Press
● Move the key to the direction of an arrow The key can be moved up, down, right, left, and diagonally. Move the key for the following purpose. • To move through menu items. • To enter values such as “TOL” (tolerance). • To move the arrow cursor on the monitor. • To change the size of a window or to move a window. Move up
Move left
ENT
Move right
Move down
33
Page 44
Chapter 4
4.1.2
Setting Procedure
Screen page layout The cursor position is displayed as highlighted on the menu screen. The menu screen has a layered structure. Use the following keys to move through the layers. For the layered structure of menu items, refer to the “Parameters” sections for each measurement mode. ● With the panel keys Use the [ENT] key, [Cursor] keys, and [ESCAPE] key. ● With the remote control console Use the [ENT] key and [ESCAPE] key. ■ Screen page layout
Image screen
4
Menu screen
CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG WIND•1
RUN/PROG display Shows the current operation mode: “RUN” or “PROG”.
DATA 000000 TOL H=000000 L= 000000 OPTION SAVE T= RAW SCR
The menu screen above is displayed when [ARE/CON] is selected from the [MODE] menu.
34
Menu screen Displayed items vary depending on the selected measurement mode.
Page 45
Chapter 4
Setting Procedure
4.2 Preparations This section describes the preparations before settings.
4.2.1
Preparations before settings
Preparations before turning on the power Check the cable connections. ➮ See page 11.
Preparations for turning on the power 1. Turn on the power. An unprocessed screen will be displayed on the monitor. 2. Aim the camera at a target and adjust the lens and illumination. ➮ See page 13.
4
Illumination
35
Page 46
Chapter 4
Setting Procedure
4.3 Basic Settings This section describes the common settings for each mode. Be sure to read all instructions carefully.
4.3.1
Basic setting procedures This section describes the setting procedures, basic information for changing settings, and how to perform the major functions.
Selecting the program number Select a program number before changing the settings. The CV-701(P)/751(P) can save up to 16 measurement parameters. Each measurement parameter is called a “Program No.”. By saving two or more parameters in advance, selection can be performed with a shift of program numbers upon target changeover. To save the previous settings, select an unused program number.
4
Note: When two cameras are connected, the available program numbers are limited to 00 through 07. Tips
Use a CompactFlash memory (➮ page 171) or RS-232C communication function (➮ page 179) to save more than sixteen sets of parameters to a personal computer. ■ Panel keys Press the PROGRAM number keys to select the program number. Pressing the “▲” key increases the number, and pressing the “▼” key decreases the number.
SCREEN WINDOW RUN PROG PROGRAM No.
■ Remote control console 1. Place the cursor on [No.].
CAM1 CAM2 PROGRAM No.00 MODE
36
Page 47
Chapter 4
Setting Procedure
2. Press the [ENT] key to display the program number selection menu. 3. Move the [ENT] key up or down to place the cursor on the desired number.
PROGRAM No.00 No.00 No.01 No.02 No.03 No.04 No.05 No.06 No.07 No.08 No.09 No.10 No.11 No.12 No.13 No.14 No.15
4
4. Press the [ENT] key to confirm the selection.
CAM1 CAM2 PROGRAM No.00
Tips
• A program number with “●” indicates that the number is already being used. • Selecting the program number can also be done by using the input terminal in RUN mode.
Setting the measurement mode The CV-701(P)/751(P) allows you to select a measurement mode best suited for the application from the following five measurement modes: “ARE/CON”, “INS/ TRG”, “INS+POS”, “ABS.POS”, and “REL.POS”. For an overview of each measurement mode, see “Mode Selection” (➮ See page 17). 1. Place the cursor on [MODE].
PROGRAM No.00 MODE 2. Press the [ENT] key to display the mode selection menu. 3. Press the [ENT] key up or down to place the cursor on the desired mode.
MODE ARE/CON INS/TRG INS+POS ABS•POS REL•POS
37
Page 48
Chapter 4
Setting Procedure 4. Press the [ENT] key to confirm the selection. The cursor will move onto [SHUTTER].
No.00 MODE ARE/CON SHUTTER Tips
To change a set measurement mode, place the cursor on “Y” and press the [ENT] key when the message <ERASE SETTINGS N/Y> appears on the screen.
Selecting a shutter speed Select a shutter speed according to the speed of the target movement. When the screen is too bright or too dark, the brightness of the screen is adjusted by changing the shutter speed. Select a shutter speed from 11 settings: 1/30 through 1/10000 of a second.
4
1. Place the cursor on [SHUTTER] and press the [ENT] key to display the shutter menu.
No.00 MODE ARE/CON SHUTTER 2. Place the cursor on the desired shutter speed and press the [ENT] key to confirm the selection.
SHUTTER 1/30 1/50 1/60 1/100 1/125 1/250 1/500 1/1000 1/2000 1/4000 1/10000 Tips
38
• When the image on the screen is blurred because the target moves too quickly, select a faster shutter speed. • Be sure to readjust the lens after changing the shutter speed, because the brightness has been changed.
Page 49
Chapter 4
Setting Procedure
Register a screen Save the image to be registered on the memory. Set measurement parameters based on the reference image. 1. Place the cursor on [SCRN REG] and press the [ENT] key to display the camera selection menu.
SHUTTER SCRN REG WIND•1 2. Press the [ENT] key when using only one camera. The message <REGISTER SCREEN N/Y> appears on the monitor screen. (When two cameras are connected, select one camera to be registered.) ➮ See page 42.
SHUTTER SCRN REG CAM1
4
3. Move the [ENT] key to the right to select “Y”. To cancel the screen registration, press the [ENT] key while “N” is highlighted. CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG CAM1
DATA 000000 TOL H=000000 L= 000000
REGISTER SCREEN N / Y
Tips
OPTION SAVE T= RAW SCR
Pressing the [TRIGGER] key while “Y” is highlighted updates the screen image. 4. Press the [ENT] key. The message <CHANGE POS N/Y> appears on the screen. Move the [ENT] key to the left to select “N”, and go to step 5. When using the position adjustment function in “INS+POS” or “ABS.POS” mode, go to the next step in the bracket. CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG CAM1
DATA 000000 TOL H=000000 L= 000000
CHANGE POS N / Y
Tips
OPTION SAVE T= RAW SCR
• The position can be changed when using the position adjustment function. If the target is projected at an angle on the screen, it can be adjusted to the proper position. • In position detection, angle detection or angle adjustment operation, the origin point is specified with the registered screen. Therefore, adjust the position and angle of the target on the registered screen to determine the origin point.
39
Page 50
Chapter 4
Setting Procedure
Position and angle setting procedure 1. The position of the target can be changed when the target is projected at an angle on the screen while the message <CHANGE POS N/Y> appears on the screen. Move the [ENT] key to the right to select “Y”. When the target is projected as straight, select “N” and press the [ENT] key. CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG CAM1 WIND•1 INSPECT AREA DATA 000000 TOL H=000000 L= 000000
CHANGE POS N / Y
OPTION SAVE T= RAW SCR
2. When “Y” is selected, the message <ARROW KEY MOVE> appears on the screen. You can scroll the screen horizontally or vertically. Adjust the position and press the [ENT] key.
4
CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG CAM1 WIND•1 INSPECT AREA DATA 000000 TOL H=000000 L= 000000
ARROW KEY MOVE
OPTION SAVE T= RAW SCR
● With the panel keys Scroll the screen by pressing the [Cursor] keys. ● With the remote control console Scroll the screen by moving the [ENT] key. 3. The message <UP/DOWN ROTATE> appears on the screen. Adjust the angle of the target so that the pattern to be searched is projected as straight in a horizontal or vertical position, and press the [ENT] key. CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG CAM1 WIND•1 INSPECT AREA DATA 000000 TOL H=000000 L= 000000
UP/DOWN ROTATE
● With the panel keys Adjust the angle by pressing the cursor keys. [▲]: Rotates the target counterclockwise. [▼]: Rotate the target clockwise. ● With the remote control console Adjust the angle by pressing the [ENT] keys. [▲]: Rotates the target counterclockwise. [▼]: Rotate the target clockwise.
40
OPTION SAVE T= RAW SCR