Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 24

CV-700 Series User's Manual: High-speed, High-accuracy, Color Vision System, pages 21 to 30

Pages 21 to 30 of 232

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence CV-070

Page 21

Chapter 2

2.1.4

Preparation

Cable connection and wiring CAUTION

•

•

Be sure to turn off the controller before connecting the cables. If you connect the cables while the controller is turned on, the camera or peripheral device may be damaged. The CV-701(P)/751(P) conforms to CE regulations in Europe; however, please make sure to keep the wiring for the power and the I/O within 30 m. Otherwise, it will not conform to EN61326-1.

1. Insert the connector for the camera cable. When using only 1 camera, insert the connector for camera one into the camera 1 slot only.

Camera 2 Camera 1

Camera 1

Camera 2

2. Insert the modular connector for the remote control console cable. With the CV-751(P), insert the modular connector only when using the optional remote control console. When using the console, slide the control selector to the right. Control selector

Right: When using the console Left: When using the panel keys

3. Insert the video output terminal (RCA connector) for the monitor cable. With the CV-751(P), insert the RCA connector only when using an external monitor. 4. Connect the cable for the power supply unit. • •

Connect the cable for the 24 VDC power supply unit to the controller’s input/ output terminals 1 and 2. Use a Philips screwdriver to connect the cable to the terminal. Do not turn on the power until the mounting procedure is complete. 1: DC24V 2: 0 V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

11

2

Page 22

Chapter 2

Preparation ■ CV-751(P)

Remote control console (Option: OP-30938) Control selector

2 24 VDC power supply unit (Option: KV-U3 or KV-U6W)

Monitor (Option: CV-M30)

Camera 1 (CV-070) Lens (Option) Camera 2

■ CV-701(P) Remote control console (Accessory)

24 VDC power supply unit (Option: KV-U3 or KV-U6W)

Camera 1 (CV-070) Lens (Option)

Monitor (Option: CV-M30) Camera 2

12

Page 23

Chapter 2

2.1.5

Preparation

Checking the connection 1. Turn on the power. Turn on the connected 24 VDC power supply. 2. Check the monitor. • •

A raw (unprocessed) screen is displayed. When two cameras are connected, the image from camera 1 is displayed.

➮

See page 42 to display the image from camera 2. CAM1 CAM2 PROGRAM No.00 MODE

T= 000000 RAW SCR

*

A raw screen is a screen that is seen through the camera without any processing.

3. Adjust the diaphragm and focus of the lens. 1) Turn the diaphragm ring and focus ring to adjust the diaphragm and focus while watching the monitor.

Focus ring lock screw

2) After the adjustment is complete, secure the lock screws to lock the rings.

Diaphragm ring lock screw

● Diaphragm adjustment Adjust the diaphragm so that the target can be easily distinguished from the background. ● Focus adjustment Adjust the focus until the target contour becomes clear. Note: Check the following items if nothing appears on the monitor. • Is the proper type of 24 VDC power supply (CV-751(P): 1.4 A, CV-701(P): 700 mA) used? Are the “+24 V” and “0 V” power supply terminals properly connected? • Is the camera cable properly connected? • Are the cables for the remote control console and monitor properly connected? (with the CV-701(P) only) • Is the lens cap removed? • Is the lens diaphragm opened wide enough? • Is the monitor turned on? • Is the video input terminal for the monitor properly connected?

13

2

Page 24

Chapter 2

Preparation 4. Adjust the monitor. (with the CV-751(P) only) The monitor for the CV-751(P) is factory-adjusted so that adjustment is unnecessary under normal conditions. If you need to make adjustments due to ambient light or the viewing angle, follow the procedure below.

2

*

The initial setting is for setting all trimmers to the middle position.

1) Adjust the color depth using the COLOR adjustment trimmer. COLOR

Light

Deep

2) Adjust the hue using the HUE adjustment trimmer. HUE

Greenish

Reddish

3) Adjust the brightness using the BRIGHT adjustment trimmer. BRIGHT

Bright

Dark

5. Adjust the time and date. The CV-701(P)/751(P) comes standard with a built-in clock function. The time and date on the clock are used when writing the data on the CompactFlash memory, etc. Adjust the time and date using the [CLOCK] on the configuration menu. ➮

See page 149.

Note 1: The secondary battery for backing up the clock function is not factorycharged. The battery can be fully charged by applying power to the controller for 24 hours. Note 2: With the power off, the time between battery recharges is approximately two months (at a temperature of 25 °C (77°F)). When it becomes low in capacity, the date and time are reset to the initial setting. (00 YEAR 01 MON 01 DAY 00 MIN 00 SEC)

14

Page 25

Chapter 2

Preparation

2.2 Illumination Use illumination for more stable detection. If you install the CV-701(P)/751(P) in a location with the following conditions, detection may not be accurate. Change the location or use the specially designed illuminator. • • •

Locations directly exposed to sunlight Locations in which the ambient light varies greatly depending on the time of day Locations in which the illumination level changes according to the movement of a machine or people

Illuminator ■ Ring lamp Mount the ring lamp around the lens to illuminate the target evenly. The ring lamp is available as an option. (CV-R11)

Ring lamp

Target

Note: The illumination lamp has a recommended service life. When the light intensity changes, detection errors may result. Replace the lamp before this problem occurs.

White balance Adjust the white balance when discoloration occurs in the target image after the lens and illumination are adjusted. ➮

See page 148.

15

2

Page 26

Chapter 2

Preparation

MEMO MEMO

2

16

Page 27

Chapter 3 Mode Selection The CV-701(P)/751(P) features five measurement methods called “measurement modes”. This section describes the functions and applications of each mode. A list of applications and modes is provided to help simple mode selection. 3.1

Measurement Modes and Typical Applications ............... 18

3.1.1 3.1.2 3.1.3 3.1.4 3.1.5

“ARE/CON” (Area continuous) ............................................... 18 “INS/TRG” (Inspection trigger) ............................................... 19 “INS+POS” (Inspection position) ........................................... 22 “ABS.POS” (Absolute position) .............................................. 23 “REL.POS” Mode ................................................................... 25

3.2

Selecting the Measurement Mode by Application ........... 27

Page 28

Chapter 3

Mode Selection

3.1 Measurement Modes and Typical Applications The CV-701(P)/751(P) features five measurement modes: “ARE/CON” (Area continuous), “INS/TRG” (Inspection trigger), “INS+POS” (Inspection + position), “ABS.POS” (Absolute position), and “REL.POS” (Relative position). This section gives an overview and describes the typical application of each mode.

3.1.1

“ARE/CON” (Area continuous) Use “ARE/CON” mode to continuously measure the area in the window for selected color data. ➮ See“4.4 “AREA” Mode Basic Settings” on page 57 for the setting procedure.

3

Functions • • •

Extracts the selected color data of the window. Sets a window and measures the area of the selected color data and the background color of the window. Up to eight windows can be drawn for a single program. The measured data and detection result for each window are output sequentially. Sample: Detection for the number of pixels

ABC

Window

Acceptable (3,000 pixels)

ABC Unacceptable (2,000 pixels)

Typical applications Use the “AREA” mode for detection of the presence or absence of a target, a missing target, and for the shape or area of a target.

18

Detecting a chip on building plywood

Checking the application quantity of the magnetic substance on magnetic films

Detecting uneven coating on an optical disk surface

Detecting uneven curtain coating in the resist process of a PC board

Page 29

Chapter 3 Tips

3.1.2

Mode Selection

Basic Unit of Area: “Pixel” The sensing element CCD of the camera forms a square grid pattern, and each minute area corresponds with a pixel. Each pixel recognizes R, G, and B as a 256level brightness signal. “AREA” mode allows you to set a window on a desired part of an image on the monitor screen and count the number of pixels matching the selected color data. You can detect the area of a target, whether it is small or large, and the presence or absence of a target.

Pixel

“INS/TRG” (Inspection trigger) Use “INS/TRG” mode to measure the selected color data in the window at every trigger input. ➮

See “4.6 “INS” Mode Basic Settings” on page 70 for setting procedure.

• •

Selects the measurement parameter by the inspection mode. The following ten inspection mode types can be selected from the inspection mode. Setting an inspection mode for each window allows for multiple detections with one target.

Functions

•

AREA Detects the presence or absence of a target, whether it is small or large, a missing target, and the area of a target as with “ARE/CON” mode. OUTER (Outer edge) Measures the distance between the outermost edges in the window. OUTER measurement Window

INNER (Inner edge) Measures the distance between the innermost edges in the window. INNER measurement Window

GAP Measures the distance between the odd-numbered edges and the even-numbered edges counted from the left (in horizontal scanning) or top (in vertical scanning) of the window. The maximum, minimum, and average values can be obtained. GAP measurement

Window

19

3

Page 30

Chapter 3

Mode Selection PITCH Measures the pitch values to obtain the maximum, minimum, and average values. PITCH measurement

Window

EDGE NO (Edge count) Use this mode to count the number of pins. Counts the number of edges in the window. (Specify the edge with [WH ➞ BL] or [BL ➞ WH].)

3

1

2

3

4

5

Window

COUNT Counts the number of clusters of extracted colors in the window. Up to 256 clusters can be counted. 8

1

2 3

7 6

5

4

POINT (Point sensor) Detects the presence or absence of the extracted colors of the set point. Up to 8 points can be detected in a window. Absence Presence

STAIN Use this mode to detect stains and defects. The four types that can be used for a window: square, circle, ring, and arc.

GRAVITY Detects the center of gravity and the angle of principal axis (the longitudinal angle) of a target.

GRAVITY center

20