Page 41

Chapter 4 Basic Functions This chapter describes in detail the normal usage and operation of the BL-V35E such as the multi-preset function and step verification function.

4.1

Multi-preset Function ......................................................... 32

4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7 4.1.8 4.1.9

Multi-preset function .............................................................. 32 Registration of preset data (Preset mode) ............................. 32 Registering preset data .......................................................... 33 Saving the preset data from any preset No. .......................... 37 Deleting preset data ............................................................... 38 Preset wildcard function ......................................................... 39 Operation (RUN mode) .......................................................... 39 Counter function .................................................................... 42 Parallel output form ................................................................ 45

4.2

Preset-active Function ....................................................... 46

4.2.1 Preset-active function ............................................................ 46 4.2.2 Using the preset-active function ............................................ 46 4.2.3 Selecting the preset data to be verified in the preset-active function .......................................................... 48 4.2.4 Operation using the preset-active function ............................ 49 4.3

Step Verification Function ................................................. 50

4.3.1 4.3.2 4.3.3 4.3.4

Step verification function ........................................................ 50 Using the step verification function ........................................ 50 Operation using the step verification function ........................ 51 Parallel output form ................................................................ 53

4.4

Serial No. Check Function ................................................. 54

4.4.1 4.4.2 4.4.3 4.4.4

Serial No. check function ....................................................... 54 Using the serial No. check function ....................................... 54 Setting the parameters of the serial No. check function ........ 55 Operation using the serial No. check function ....................... 59

4.5

Key Input Procedure ........................................................... 61

4.6

Parallel Inputs ..................................................................... 64

Page 42

Chapter 4

4.1

Basic Functions

Multi-preset Function The multi-preset function compares the data registered in advance (preset data) to the readout bar code data.

4.1.1 Multi-preset function The preset function compares the data registered in advance (preset data) to the readout bar code data. It then produces outputs to indicate whether or not the readout data matches one of the data presets. The BL-V35E stores up to 399 data presets and compares them to the readout bar code data. When the readout data matches the preset data, the BL-V35E outputs the number assigned to the preset data using a bit, binary value, or BCD number from the parallel port. BL-V35E

4

Preset No.

Preset data

Output No.

1 2 3 • • • 399

*AB* *CD* *10* • • • *50*

1 2 3 • • • 399

Readout Comparison data

Bar code reader

RS-232C

*CD*

External device

Parallel output Bit Binary BCD

4.1.2 Registration of preset data (Preset mode) Before registering preset data, the following items must be set in the main setting mode. (➮ See p. 92) •

No. of preset registration values [Max Preset No.]

•

Form of parallel output [OUT]

•

Automatic increment function (ON or OFF) [Auto Increment]

There are 2 methods for registering preset data. ● Read bar codes using a stationary bar code reader (BL series). You can register the preset data by reading bar codes using bar code readers such as the BL series. ● Enter data using the panel keys. You can manually register the preset data by entering bar codes using the BLV35E’s panel keys. (➮ See p. 34)

32

Page 43

Chapter 4

Basic Functions

4.1.3 Registering preset data ■ When registering preset data using the panel keys Procedure 1. Press the [PRESET] key. The preset LED turns on and the BL-V35E enters preset mode. The preset No. display LED displays "1", and the LCD display shows "(empty)" to indicate that no preset data is registered.

PRESET

1 TIM 1 TIM 2

( emp t y )

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

4

2. Read the bar code using the bar code reader. The beeper sounds and the readout data is registered as preset data. •

When the Auto-increment function is ON, the number in the preset No. display is incremented by 1, and the next bar code data can be registered immediately.

•

When the Auto-increment function is OFF, press the select the desired preset number. PRESET

5 4 3 2 1

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

▲ or

▼ key to

IN 4 3 2 1 OUT

9

8 7 6 5 OK 10 9

4

5

6

1

2

3

0

CLEAR

NG

PRESET

CANCEL

ENTER

If a reading error occurs while the stationary type bar code reader is connected, a reading error code (“ERROR” with the BL series) is registered as preset data. When this happens, you must repeat the registration. 3. Repeat the procedure above until all necessary data is registered. Continue to register preset data up to the specified number of preset registration values (default value: 10). You cannot register more than the specified number of preset registration values. (➮ See p. 92) 4. Complete the registration. When all preset data is registered, press the [PRESET] key. The preset LED turns off and the BL-V35E exits preset mode.

PRESET

TIM 1 TIM 2

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

K E Y E N C E

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

1

2

0

CLEAR

PROGRAM

MONITOR

This completes registration of preset data using a bar code reader.

33

Page 44

Chapter 4

Basic Functions ■ When registering preset data using the panel keys Procedure 1. Press the [PRESET] key. The preset LED turns on and the BL-V35E enters preset mode. The preset No. display LED displays "1", and the LCD display shows "(empty)" to indicate that no preset data is registered.

PRESET

1 TIM 1 TIM 2

( emp t y )

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

2. Press the [DATA] key. The LED above the [DATA] key turns on and the LCD display shows "_". To enter numerical values, enter them using the numeric keypad. • When an incorrect number is entered, press the [BACK SPACE] key once to delete one character.

4

[BACK SPACE] key

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

PROGRAM

MONITOR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

BL-V35

3. Complete the registration. When all preset data is registered, press the key to turn off the LED above the [DATA] key . Then, press the [PRESET] key to turn off the Preset LED. The BL-V35E exits preset mode.

PRESET

TIM 1 TIM 2

1 2 3

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

1

PROGRAM MONITOR

BL-V35E

8 7 6 5 OK 10 9 NG

2 KEYENCE

PRESET

CANCEL

ENTER

This completes registration of preset data using the panel keys.

34

Page 45

Chapter 4

Basic Functions

■ Entering letters or symbols using the panel keys Procedure 1. Press the [PRESET] key. The preset LED turns on and the BL-V35E enters preset mode. The preset No. display LED displays "1", and the LCD display shows "(empty)" to indicate that no preset data is registered.

PRESET

TIM 1 TIM 2

( emp t y )

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

2. Press the [DATA] key. The LED above the [DATA] key turns on and the LCD display shows "_".

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

4

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM

3. Press the [SHIFT SYMBOL] key. The LED above the [SHIFT SYMBOL] key turns on. A flashing "A" appears at the cursor position on the LCD display.

PRESET

TIM 1 TIM 2

A

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

4. Enter letters or symbols. Press the ▲8 or 2 key to change the character at the cursor position in sequence. Continue until the desired character or symbol appears. • When the [CLEAR] key is pressed, characters can be skipped in order of "A, a, *, !, ?, _(space), 0, ", °, and _". It is useful to use the [CLEAR] key to move to the character closest to the desired one, and then use the character. (➮ p.63)

▲ 8

2 or key to choose the desired

Change characters.

PRESET

TIM 1 TIM 2

A

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

Skip characters

35

Page 46

Chapter 4

Basic Functions 5. Press the

6 key.

When the 6 key is pressed, the cursor moves one character to the right. Enter the next character using the same procedure as in step 4. • When the 4 key is pressed, the cursor moves to the previous position. Use this key to correct the character if desired.

PRESET

TIM 1 TIM 2

A

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

To previous position

To next position

6. Press the key to complete the character input. The LED above the [SHIFT SYMBOL] turns off and the BL-V35E returns to the numerical value input mode.

4

PRESET

TIM 1 TIM 2

A BCD 1 2 3

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

DELETE

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

7. Complete the registration. When all preset data is registered, press the key again. The LED above the [DATA] key turns off. Press the [PRESET] key to turn off the Preset LED. The BL-V35E exits preset mode.

PRESET

TIM 1 TIM 2

A BCD 1 2 3

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

1

PROGRAM MONITOR

BL-V35E

8 7 6 5 OK 10 9 NG

2 KEYENCE

PRESET

CANCEL

ENTER

Note: The data entered using the panel keys is not saved until the LED above the [DATA] key turns off.

This completes registration of letters and symbols in preset data.

36

Page 47

Chapter 4

Basic Functions

4.1.4 Saving the preset data from any preset No. Preset data can be saved from any No. Press the [PRESET] key to select the preset mode, and then select any No. using either of the following two methods. ■ Pressing the

▼

▲ or key

While the preset LED is illuminated, press the ▼ or ▲ key and select a desired preset No. • When this method is used, a preset No. can be specified within the range of saved preset data.

PRESET

3 TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

Select the preset No.

4 ■ Pressing the [PRESET No.] key When the [PRESET No.] key is pressed, the LED above it illuminates. Use the numeric keypad to enter a desired No. from which registration is started, and then press the key. • When this method is used, a preset No. beyond the range of saved preset data can be specified. •

To display the minimum unregistered preset No., press the ately after pressing the [PRESET No.] key.

key immedi-

1 PRESET

16 TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

2 3 BL-V35E

This completes preparation for saving preset data from any preset No.

37

Page 48

Chapter 4

Basic Functions

4.1.5 Deleting preset data Use the [CANCEL] key to delete registered preset data.

Procedure 1. Press the [Preset] key. The preset LED turns on and the BL-V35E enters preset mode.

PRESET

1 TIM 1 TIM 2

A BCD

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

2. Select the preset No. to be deleted. Press the ▲ or ▼ key to select the preset No. to be deleted. The preset No. can also be specified by entering the preset No. using the numeric keypad.

4

PRESET

3 TIM 1 TIM 2

12345

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

Select the preset No.

3. Press the [CANCEL] key. When the preset No. is selected, the current preset data is displayed. To delete the displayed data, press the [CANCEL] key. • When the data is deleted, "(empty)" appears on the LCD display.

PRESET

3 TIM 1 TIM 2

( emp t y )

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

PROGRAM

MONITOR

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

BL-V35E

Delete the preset data.

4. Complete the operation. When the desired preset data is deleted, press the [PRESET] key. The Preset LED turns off and the BL-V35E exits preset mode.

PRESET

TIM 1 TIM 2

( em p t y )

4 3 2 1 OUT

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

This completes deletion of preset data.

38

CANCEL

ENTER

1

2

0

CLEAR

PROGRAM

MONITOR

Page 49

Chapter 4

Basic Functions

4.1.6 Preset wildcard function Entering a "!" or "?" symbol in the preset data using the panel keys widens the range of the bar code data to be matched. ?: Represents any numbers (characters) in the bar code data. When the preset data is "4912??56", any numbers (characters) are accepted in the "??" positions. This enables flexible comparison. !: Represents certain numbers (characters) in the bar code data. When the preset data is "4912!", all bar codes starting with "4912" are considered to be matched. When the preset data is "!4912", all bar codes ending with "4912" are considered to be matched.

Example ABCD OK ABCD OK

1. When preset data is "ABC?" 2. When preset data is "ABC!"

ABC3 ABC ABCDE OK NG NG ABC3 ABC ABCDE OK OK OK All 5-digit bar codes OK 3CDE CDE ABBDE OK OK NG A3CE ABCD AE OK NG OK

3. When preset data is "?????" ABCDE OK ABCDE OK

4. When preset data is "!CDE" 5. When preset data is "A!E"

AB NG ADE NG

Note: Only a single "!" can be used in a single preset data.

4.1.7 Operation (RUN mode) After preset data registration, the BL-V35E operates as follows (RUN mode). ■ Reads bar codes. Read bar codes using a stationary bar code reader (BL series). • You can also enter numbers or letters using the panel keys (➮ See p. 61) PRESET

5 4 3 2 1

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

IN 4 3 2 1 OUT

9

8 7 6 5 OK 10 9

4

5

6

1

2

3

0

CLEAR

NG

PRESET

CANCEL

ENTER

● When readout data matches with preset data: Preset No. display LED: Displays the preset data that matches the readout data. LCD display: Displays the readout data. Counter function: Increments the counter of the preset data that matches the readout data. Parallel output: Outputs OK and appropriate OUT signals in the specified output form. (➮ See p. 45) Matched preset No.

PRESET

3 TIM 1 TIM 2

AB1 2 3 4 5

4 3 2 1

(

6 )

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

Data Parallel output (OK + OUT 1 to 10)

BL-V35E

Counter value

[OK] LED illuminates.

39

4