Page 29

Chapter 3 Wiring and Installation This chapter describes the specifications of the parallel interface and serial interface of the BL-V35E. This chapter also describes the wiring between the BL-V35E and various other units.

3.1

Mounting .............................................................................. 20

3.2

Connecting the Power Supply ........................................... 22

3.2.1 Connecting the power supply ................................................ 22 3.3

Wiring the Parallel Interface .............................................. 23

3.4

Wiring the Serial Interface ................................................. 25

3.4.1 Pin assignment for serial interface ......................................... 25 3.4.2 Connecting a bar code reader ............................................... 25 3.4.3 Connecting an external unit ................................................... 27

Page 30

Chapter 3

3.1

Wiring and Installation

Mounting This section describes how to mount the BL-V35E. The BL-V35E can be mounted using either of the following methods. Metal fixture for direct mount

Fixture for mount to DIN rail Metal fixture for direct mount

Rubber pad

Rubber pad

3 Bottom of BL-V35E

■ Placement Place the BL-V35E on a desk, etc. ■ Direct mount Pull out the metal fixtures for direct mount provided on the bottom of the BL-V35E, and tighten the fixtures using screws. 4- ø5 (mounting hole)

150

PRESET

PRESET No.

DATA

COUNT

ABC..

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

5 4 3 2 1 IN 4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

98

■ Mount to panel For the panel cut dimensions, refer to the outline drawing (➮ See p. 135).

Bottom

1

2

Secure the BL-V35E temporarily with 1, and then secure it permanently with 2.

CAUTION

20

Be sure to tighten the screws by hand. If a tool is used, the case may be damaged.

Page 31

Chapter 3

Wiring and Installation

■ Mount to DIN rail The BL-V35E can be mounted to a DIN rail using the following procedure.

Procedure 1. Metal fixtures for mount to a DIN rail are provided on the bottom of the BLV35E. Pull out the metal fixtures to the position shown in the figure.

2. Hook the lower part of a DIN rail to the claws of the BL-V35E, and push into the BL-V35E.

3. Push into the metal fixtures completely until a clicking sound is heard. This indicates that the BL-V35E is secured.

PRESET

5 4 3 2 1

PRESET No.

DATA

COUNT

SYMBOL SHIFT

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

IN 4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

4. When the BL-V35E is not mounted to a DIN rail, push into the metal fixtures completely so that the end of each fixture is flush with the BL-V35E main body.

21

3

Page 32

Chapter 3

3.2

Wiring and Installation

Connecting the Power Supply This section describes how to connect the power supply to the BL-V35E.

3.2.1 Connecting the power supply The BL-V35E uses 100 to 120 VAC (50/60 Hz) as the power supply. Confirm the rated voltage of the power supply, turn off the POWER switch of the BL-V35E, and then connect the power cable.

3

CAUTION

22

If a power supply’s rated input voltage is different from the specified value, failures or accidents may occur. Be sure to use a power supply with 100 to 120 VAC (50/60 Hz).

Page 33

Chapter 3

3.3

Wiring and Installation

Wiring the Parallel Interface This section describes the parallel interface of the BL-V35E. The parallel interface handles outputs representing the result of comparison to the preset data (OK/NG/OUT1 to OUT10), and sends trigger inputs to a bar code reader connected to the serial interface. ■ Pin assignment and names 13 12 11 10 9 8 7 6 5 4 3 2 1 Main unit side D-sub 25-pin connector (female) M2.6 screw

25 24 23 22 21 20 19 18 17 16 15 14

Pin No.

Name

1

OK output

14

NG output

2, 15

COM2

4

OUT1 output

17 5 18 6 19 7 20 8 21 3, 16 9 22 10 23 11 24 12 13, 25

Description Outputs a signal when the readout data matches the preset data (verification OK). • Outputs a signal when the readout data does not match the preset data (verification NG). • Outputs a signal when an error (➮ See p. 139) has occurred. (Either one can be selected in the option set mode. ➮ See p. 96) Common for OK/NG output

OUT2 output OUT3 output OUT4 output Outputs the output No. corresponding to the preset data that matches the readout data. OUT5 output Bit output (preset No.: 1 to 10) OUT6 output Binary output (preset No.: 1 to 399) OUT7 output BCD output (preset No.: 1 to 399) OUT8 output OUT9 output OUT10 output COM1 Common for output Timing (trigger) input to a BL series bar code reader TIM1 connected to serial port 1 (PORT 1) Timing (trigger) input to a BL series bar code reader TIM2 connected to serial port 2 (PORT 2) IN1 Functions in the same way as the [ENTER] key. IN2 Functions in the same way as the [CANCEL] key. IN3 Functions in the same way as the ▲ key. IN4 Functions in the same way as the ▼ key. Functions in the same way as the [PRESET No.] IN5 key. ➮ See p. 64 IN COM Common for input

Signal direction Output

Output

Output

Output

Output Input Input Input Input Input Input Input Input

23

3

Page 34

Chapter 3

Wiring and Installation ■ I/O circuit diagram Input circuit

Output circuit

OUT INCOM

23V (Insulated power supply)

L

Internal circuit

To internal circuit

12 KΩ IN

COM

Photocoupler 4.7 KΩ

+

3 ■ Wiring and connection

*

OUT10 OUT8 21

OUT6

OUT4

19

18

20

Pins 3 and 16 (COM1) are common inside. Pins 2 and 15 (COM2) are common inside. Pins 13 and 25 (INCOM) are common inside.

OUT1 COM1 COM2 4

3

OUT2 COM1 COM2 17

16

15

+

OK

2

+

1

NG 14

LOAD

5

LOAD

22

OUT3

6

LOAD

TIM2

23

OUT5

7

LOAD

IN2

24

LOAD

IN4

25

LOAD

INCOM

OUT7

8

LOAD

9

LOAD

TIM1 OUT9

10

LOAD

IN1

11

LOAD

IN3

12

LOAD

IN5

13

LOAD

INCOM

COM1, COM2 and INCOM are insulated from each other.

* The rated load of output terminals is 30 V (100 mA) maximum. Note: For a photoelectric sensor connected to TIM1 or TIM2, be sure to use a power supply other than that of the BL-V35E. One D-sub 25-pin connector (male) and one connector case are available as accessories. Refer to the specifications above, and prepare the connector. • 25-pin connector: DB-25PF-IN manufactured by NIHON KOKU DENSHI KOGYO or its equivalent • Connector case: DB-C8-J10-F1-1 manufactured by NIHON KOKU DENSHI KOGYO or its equivalent

24

Page 35

Chapter 3

3.4

Wiring and Installation

Wiring the Serial Interface This section describes the serial interface ports of the BL-V35E. Two serial interface ports, PORT 1 and PORT 2, are provided. Connect a personal computer or PLC to PORT 1. Connect a bar code reader to PORT 2.

3.4.1 Pin assignment for serial interface 1 2 3 4 5

6 7 8 9

*

Main unit side D-sub 9-pin connector (male) #4-40 screw DCE specifications

3

Both PORT 1 and PORT 2 have the same structure. Signal direction Provides timing (trigger) outputs to a bar code reader. Output

Pin No.

Name

Description

1

TIM

2

RD (RXD)

Sends data.

Output

3

SD (TXD)

Receives data.

Input

4

ER (TDR)

Connected to pin No. 6 inside.

Input

5

SG

6

DR (DSR)

Signal ground

7

RS (RTS)

Enables send.

Input

8

CS (CTS)

Provides send requests (always ON).

Output

9

Vcc

+5 V power supply

Output

Connected to pin No. 4 inside.

–– Output

3.4.2 Connecting a bar code reader Typically, you should connect a bar code reader to serial port 2 (PORT 2). However, when the connected unit is set to “bar code reader” in the communication set mode for serial port 1 (PORT 1), a bar code reader can also be connected to serial port 1. ■ Connecting a BL series bar code reader Connect a BL series bar code reader directly to serial port 2. Connect trigger inputs to the parallel interface of the BL-V35E. The +5 VDC power is supplied from the BL-V35E.

PORT 2 (READER)

25

Page 36

Chapter 3

Wiring and Installation ■ Connecting a bar code reader manufactured by another company The wiring varies depending on the bar code reader to be connected. Read the Instruction Manual for the bar code reader. Use the following wiring diagram for reference.

Wiring example Bar code reader manufactured by another company

3

BL-V35E

FG

–

Connector case

SD

2

RD

RD

3

SD

RS

7

RS

CS

8

CS

SG

5

SG

DR ER

D-sub 9-pin connector (female) #4-40 screw

Note: When two bar code readers are connected, the capacity of the 5 VDC power supply supplied from the BL-V35E to the bar code readers is 750 mA maximum including PORT 1 and PORT 2. Ensure that the current consumption of all connected bar code readers does not exceed 750 mA. The current consumption of each bar code reader connected directly is as follows. • BL-600 series: 330 mA or less • BL-180 series: 300 mA or less • BL-500 series: 320 mA or less • BL-500H series: 340 mA or less • BL-700 series: 510 mA or less • BL-P1E (setup console for BL): 120 mA or less

26

Page 37

Chapter 3

Wiring and Installation

3.4.3 Connecting an external unit Connect an external unit such as a personal computer or PLC to serial port 1 (PORT 1). ■ Connecting a PC (personal computer) PC –

–

Connector case

RD

2

2

RD

SD

3

3

SD

RS

7

7

RS

CS

8

8

CS

ER

4

4

ER

DR

6

6

DR

SG

5

5

SG

D-sub 9-pin (female) #4-40 screw

*

BL-V35E (PORT 1)

Connector case

3

D-sub 9-pin (female) #4-40 screw

Optional cables OP-29859 (1.5 m) can be used for connection.

■ Connecting a multi-drop controller N-400 N-400 FG

1

–

Connector case

SD

2

2

RD

RD

3

3

SD

RS

4

7

RS

CS

5

8

CS

DR

6

4

ER

ER

20

6

DR

SG

7

5

SG

D-sub 25-pin (male) M2.6 screw

*

BL-V35E (PORT 1)

D-sub 9-pin (female) #4-40 screw

Optional cables OP-22149 (1.5 m) and conversion connectors OP-25057 can be used for connection.

■ Connecting a serial printer When connecting the serial printer DPU-414 manufactured by SEIKO Instruments Inc., perform wiring as follows. DPU-414

BL-V35E (PORT 1)

Connector case

–

–

Connector case

TXD

2

2

RD

RXD

3

3

SD

NC

7

7

RS

RTS

8

8

CS

GND

5

5

SG

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

27

Page 38

Chapter 3

Wiring and Installation ■ Connecting another BL-V35E When PORT 2 of another BL-V35E unit is connected to PORT 1 of the BL-V35E to which a bar code reader is connected, the data read by the bar code reader is also input to the other BL-V35E. In this way, more than 399 data presets can be set. BL-V35E

BL-V35E

Connector case

–

–

Connector case

RD

2

2

RD

SD

3

3

SD

RS

7

7

RS

CS

8

8

CS

SG

5

5

SG

D-sub 9-pin (female) #4-40 screw

3

D-sub 9-pin (female) #4-40 screw

* Optional cables OP-27937 (2 m) can be used for connection. To copy the settings between two BL-V35E units, connect PORT 1 of each BLV35E unit to each other (➮ See p. 74). ■ Connecting a KV series serial port In the following configuration, a KV series serial port can be connected. Serial port 1 (PORT 1) PRESET

PRESET

DATA

COUNT

No.

BACK

ABC..

OPTION

7

8

9

4

5

6

1

2

3

0

CLEAR

SPACE

5 4 3 2 1 IN 4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

OP-24045 (1m) OP-24025 (5m)

KV-10,16,24 KV-40,80

OP-96369

OP-25057

CANCEL

ENTER

BL-V35E

KV-300

■ Connecting a KV-L2 unit Connecting PORT 1

KV-L2 1

–

Connector case

KV-L2

BL-V35E (PORT 2) –

Connector case

SD

2

2

RD

SD

3

2

RD

RD

3

3

SD

RD

5

3

SD

RS

4

7

RS

7

RS

CS

5

8

CS

8

CS

DR

6

4

ER

4

ER

ER

20

6

DR

6

DR

5

SG

5

SG

7

D-sub 25-pin (male) M.2.6 screw

28

BL-V35E (PORT 1)

FG

SG

*

Connecting PORT 2

D-sub 9-pin (female) #4-40 screw

Optional cables OP-29860 (1.5 m) can be used for connection.

SG

1

Terminal block

D-sub 9pin (female) #4-40 screw

Page 39

Chapter 3 ■ Connecting the MELSEC-A series Connecting an AJ71C24/ AJ71C24-S■/A0J2-C214-S1/ AJ71UC24 unit Link unit FG

1

BL-V35E (PORT 1) – Connector cable 2 RD

Wiring and Installation

Connecting an A1SJ71(U)C24R2/PRF/A2CCPUC24/ A2CCPUC24-PRF unit Link unit Connector – cable RD 2

BL-V35E (PORT 1) – Connector cable 2 RD

SD

2

RD

3

3

SD

SD

3

3

SD

RS

4

7

RS

RS

7

7

RS

CS

5

8

CS

CS

8

8

CS

DR

6

4

ER

ER

4

4

ER

SG

7

5

SG

DR

6

6

DR

CD

8

6

DR

SG

5

5

SG

ER

20

CD

1

D-sub 25-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

■ Connecting the SYSMAC-C series Connecting a C200H-LK201(-V1)/ C500-LK203/C500-LK201-V1/ C120LK201-V1 unit Link unit

BL-V35E (PORT 1) – Connector cable 2 RD

FG

1

SD

2

RD

3

3

RS

4

7

CS

5

SG

7

D-sub 25-pin (male) M2.6 screw

D-sub 9-pin (male) M2-6 screw

3 D-sub 9-pin (female) #4-40 screw

Connecting a C20H/C28H/C40H/ C60H unit

PLC

BL-V35E (PORT 1) Connector – cable 2 RD

FG

1

SD

2

SD

RD

3

3

SD

RS

RS

4

7

RS

8

CS

CS

5

8

CS

5

SG

SG

7

5

SG

D-sub 9-pin (female) #4-40 screw

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

* Optional cables OP-29860 (1.5 m) can be used for connection.

■ Connecting the SYSMAC-C series Connecting a C200HS (CPU21/23/31/33)/CQM1 (CPU21/41/42/43/44)/ C200HE (CPU42)/C200HG (CPU43/63)/C200HX (CPU44/64)/C200HWCOM02/COM04/COM05/COM06 unit PLC

BL-V35E (PORT 1) Connector – cable 2 RD

FG

1

SD

2

RD

3

3

SD

RS

4

7

RS

CS

5

8

CS

SG

9

5

SG

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

29

Page 40

Chapter 3

Wiring and Installation ■ Connecting the SYSMAC-CV series Connecting a CV500-LK201 unit (PORT 1)

Link unit FG

1

1

BL-V35E (PORT 1) Connector – cable 2 RD

SD

2

SD

2

3

3

SD

RD

3

3

SD

RS

4

7

RS

RS

4

7

RS

CS

5

8

CS

CS

5

8

CS

SG

7

5

SG

SG

9

5

SG

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

D-sub 9-pin (female) #4-40 screw

* Optional cables OP-29860 (1.5 m) can be used for connection.

30

PLC FG

RD

D-sub 25-pin (male) M2.6 screw

3

BL-V35E (PORT 1) - Connector cable 2 RD

Connecting a CV500-LK201 (PORT 2)/CV500/CV1000/CVM1 unit