For the Keyence BL-V35E
Page 21
Chapter 2 Setup Procedure This chapter describes the setting procedure required before the BL-V35E is connected to a BL series bar code reader, the setting procedure for a BL series bar code reader connected via the BL-V35E, and the test procedure.
2.1
Connection and Settings ................................................... 12
2.2
Setting BL Series Bar Code Reader .................................. 14
2.2.1 Changing settings using the setup software .......................... 14 2.2.2 Changing the settings using the BL-P1E (Not available with BL-600) ................................................ 15 2.3
Using BL Series Bar Code Reader’s Test Mode .............. 17
2.3.1 Sending test mode command from the BL-V35E to the BL series .......................................................................... 17 2.3.2 How to send other commands ............................................... 18
Page 22
Chapter 2
2.1
Setup Procedure
Connection and Settings This section describes the preparations required before using the BL-V35E. ■ Preparations required before using the BL-V35E Procedure 1. Change the communication parameters of the bar code reader as follows. • Baud rate: 9600 bps • Data length: 7 bits • Parity: Even • Stop bit length: 1 bit • Data format: Data [CR] or Data [CR] + [LF] • Communication protocol: No handshaking
2
•
When the BL series is used, the above changes are unnecessary.
Note: If you cannot change the parameters using the bar code reader, use the BL V35E’s "PORT2 MODE SETUP" (➮ See p.90.) to change the parameters of the bar code reader. 2. Connect the bar code reader to serial port 2 (PORT 2) of the BL-V35E. (➮ See p.25.) 3. Read a bar code using the connected bar code reader and see if the readout data is displayed on the BL-V35E’s LCD display. 1 9 7 3 1 2 1 9
PRESET
5 4 3 2 1
PRESET No.
DATA
COUNT
SHIFT SYMBOL
OPTION
BACK SPACE
7
8
9
4
5
6
1
2
3
0
CLEAR
IN 4 3 2 1 OUT 8 7 6 5 OK 10 9 NG
PRESET
• •
*
CANCEL
ENTER
With the BL-600/700 series, read a bar code by lightly pressing the test switch once. With the BL-180/500 series, press the following keys. If the following operation does not turn on the laser, ensure that steps 1 and 2 in the procedure were performed properly. SHIFT SYMBOL
➞
7
(LON)
➞
Laser turns ON.
SHIFT SYMBOL
➞
4
(LOFF) ➞
Laser turns ON.
The key operations above cause the BL-V35E to send laser ON/OFF commands to the BL-180/500.
4. Change the detailed settings for the bar code reader connected to the BLV35E (type of bar code to be read, etc.). • With the BL series, use the setup software supplied with each model or the BLP1E handheld programmer. To use the setup software: See p. 14. To use the BL-P1E handheld programmer: See p. 15.
12
Page 23
Chapter 2
Setup Procedure
5. Adjust the detailed settings of the BL-V35E according to the application. • Operation mode (Main setting mode: ➮ See p.92.) • External device to be used (➮ See p. 84.) • Registration of preset data (➮ See p. 33.) 6. Connect the trigger input. • When the BL series is used, connect the trigger input to the BL-V35E (➮ See p. 23). 7. Connect the parallel output (➮ See p. 23). This connection is required only when the parallel output is used. 8. Connect an external unit (➮ See p. 27). Change the settings for a connected external unit. Changing the settings is not required when an external unit is not connected. For the control procedure and the operating procedure of a connected external unit, refer to the following page. • Personal computer (serial communication)
➮ p. 99
• PLC (PLC link)
➮ p. 111
• Printer
➮ p. 123
9. Use the BL-V35E, and ensure that it is operating normally.
This completes preparations for using the BL-V35E.
13
2
Page 24
Chapter 2
2.2
Setup Procedure
Setting BL Series Bar Code Reader To change the settings of the BL series, use the special setup software or the BLP1E handheld programmer. This section describes the setup procedure.
2.2.1 Changing settings using the setup software This method allows changes to the BL series settings using the setup software by sending commands via the BL-V35E.
Procedure
2
1. Follow procedures 1 through 3 in "2.1. Connection and Settings". 2. Connect a personal computer to serial port 1 (PORT 1) of the BL-V35E using an RS-232C cable. (➮ See p. 27) 3. Start the BL setup software. Change the settings of the BL series as desired. See the User’s Manual for each model for instructions on how to use the BL setup software. Note: Do not change the communication parameters such as baud rate, parity check, stop bit length, header, terminator, and communication protocol. These changes disable communication between the personal computer and the BL-V35E. 4. Set the BL-V35E to set mode. Press and hold the BL-V35E’s [0] key for 2 seconds to enter PROGRAM mode. The menu shown above appears on the LCD display. The communication parameters of the BL-V35E’s serial port 1 (PORT 1) are temporarily set as follows.
1 ) Po r t 1 3 ) Ma i n
2 ) Po r t 2 4 ) Op t i o n
• Baud rate: 9600 bps • Data length: 7 bits • Parity: Even • Stop bit length: 1 bit • Connected device: Personal computer • Communication protocol: No handshaking Note: Set mode is also used to change the settings of the BL-V35E itself (➮ See p. 80). 5. Send the setting data. When the BL-V35E shows the display described in step 4, send the settings of the BL setup software to the connected BL series. 6. Exit set mode. When the setting data is sent, press the BL-V35E’s [CANCEL] key to exit set mode.
This completes setup of the BL series using the setup software and the BL-V35E.
14
Page 25
Chapter 2
Setup Procedure
2.2.2 Changing the settings using the BL-P1E (Not available with BL-600) This procedure allows changes to the settings in the BL series using the BL-P1E via the BL-V35E. Two connection methods are available. ■ Connecting the BL-P1E using a dedicated cable available as an accessory of the BL-P1E Connect the BL-P1E as follows using a dedicated cable available as an accessory of the BL-P1E. POWER
100-120 V AC
PARALLEL
PORT 1
PORT 2 (READER)
Dedicated cable: 2 m (available as an accessory of BL-P1E)
BL series
*
2
BL-P1E
For the setting procedure in this case, refer to the BL-P1E User’s Manual.
■ Connecting the BL-P1E using an optional cable Connect the BL-P1E as follows using an optional cable OP-31097.
POWER
100-120 V AC
PARALLEL
PORT 1
PORT 2( READER)
Optional cable: 2 m (OP-31097) BL-P1E
BL series
Procedure 1. Follow steps 1 through 3 in “2.1 Connection and Settings”. 2. Set the BL-V35E to set mode. Press and hold the BL-V35E’s [0] key for 2 seconds to enter set mode. The menu shown below appears on the LCD display. 1 ) Po r t 1 3 ) Ma i n
2 ) Po r t 2 4 ) Op t i o n
3. Connect the BL-P1E to serial port 1 (PORT 1) of the BL-V35E as shown in the figure on the previous page. 4. Change the settings. Set the slide switch of the BL-P1E to SETUP. When the menu shown below appears on the LCD display of the BL-P1E, change the settings while referring to the BL-P1E User’s Manual. Menu Code1, Code2, Code3
15
Page 26
Chapter 2
Setup Procedure Note: If the message shown below appears on the LCD display of the BL-P1E when the BL-P1E is connected, check the connection between the BL-P1E, the BLV35E and the BL series bar code reader. Ensure that the BL-V35E is set to set mode as described in step 2, and then press the BL-P1E’s [ESC] key. Non-connection Push < ESC > Key
5. Exit set mode. When the settings are completed, press the BL-V35E’s [CANCEL] key to exit set mode. Return the connection to the initial status.
2
This completes setup of the BL-V35E using the BL-P1E.
Note: BL-P1E is not available with BL-600.
16
Page 27
Chapter 2
2.3
Setup Procedure
Using BL Series Bar Code Reader’s Test Mode This section describes how to use the BL-V35E to send test mode commands to the BL series.
2.3.1 Sending test mode command from the BL-V35E to the BL series Procedure 1. Set the BL-V35E to monitor mode. Before entering test mode, press and hold the BL-V35E’s [CLEAR] key for 2 seconds to enter monitor mode. <Mo n i t o r mo d e > S t a r t
Note: When test mode starts, a large quantity of data is sent from the BL series bar code reader to the BL-V35E. The BL-V35E normally compares all received data to the preset data, and then outputs the results from the parallel port. However, the operation above prevents the BL-V35E from comparing received data with the preset data as well as producing the parallel output. Therefore, the reading test does not affect the operation of the external devices connected to the BL-V35E. This mode is called monitor mode. 2. Send the test mode command to the BL series bar code reader. Check the connection between the BL series and serial port 2 of the BL-V35E. Then, press the following keys. ● Reading rate check mode SHIFT SYMBOL
➞
9
(TEST1)
<Sh i f t TEST 1
9>
Reading rate check mode: The bar code reader scans a bar code 100 times and analyzes how many times it can decode the scanned data. This mode is used to adjust the reading distance and angle of the bar code reader. ● Tact check mode SHIFT SYMBOL
➞ 6 (TEST2)
<Sh i f t TEST 2
6>
Tact check mode: The bar code reader counts how many scans can be decoded while reading one bar code. This mode is used for moving bar code labels, in order to determine the line speed that can be expected when the bar code reader is actually implemented in the line. 3. Read the bar code in the selected test mode. The readout data and the reading rate (No. of successful readings) are shown on the LCD display. The monitor indicator on the lower right corner rotates to indicate that the BL-V35E is receiving data. ABC 1 2 3 4 : 1 0 0% / Monitor indicator
Note: If the total of the readout bar code data and the additional data (reading rate, etc.) exceeds 32 characters, the BL-V35E cannot receive the data. Limit the total data to be sent to less than 32 characters. In monitor mode, both the serial and parallel outputs are disabled.
17
2
Page 28
Chapter 2
Setup Procedure 4. Exit test mode. Press the following keys to exit test mode. SHIFT SYMBOL
➞
3
(QUIT)
<Sh i f t QU I T
3>
5. Exit monitor mode. Once the BL-V35E exits test mode, press the [CLEAR] key to exit monitor mode.
2
<Mo n i t o r mo d e > End
This completes test mode operation of the BL series bar code reader.
2.3.2 How to send other commands In addition to commands for starting up test mode, the following commands can also be sent using the [SHIFT SYMBOL] key. •
➞ 6 ➞ : #TEST1 Starts up on-line test mode (available in the BL-700 series only).
•
SHIFT SYMBOL
➞ 5 ➞ : #QUIT Exits on-line test mode (available in the BL-700 series only).
•
SHIFT SYMBOL
➞ 7 ➞ Starts readout.
: LON
•
➞ 4 ➞ Finishes readout.
: LOFF
SHIFT SYMBOL
SHIFT SYMBOL
The commands above can be sent even while the BL-V35E is not set to monitor mode.