Page 50

Chapter 4

Basic Functions ● When readout data does not match the preset data: LCD display: Displays the readout data. Counter function: Increments the counter of preset No. 0. Parallel output: Outputs NG signal. (➮ See p. 45) Preset No.

Readout data

PRESET

0 TIM 1 TIM 2

ABC1 2 3 4 5

4 3 2 1

(

OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

2 )

8 7 6 5 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

Parallel output (NG)

BL-V35E

Counter value of preset No. 0

[NG] LED illuminates.

Note: The counter value is displayed only when the counter function is ON. (➮ See p. 42) Verification continues using the next preset data.

4

■ Checking the operation of parallel output In RUN mode, parallel output can be performed manually so that the parallel output operation can be checked.

Procedure 1. Select a preset No. to be checked. Press the ▼ or ▲ key or press the [PRESET No.] key, and then select a preset No. whose operation is to be checked.

PRESET

TIM 1 TIM 2

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

2. Press the [ENTER] key. When the [ENTER] key is pressed, parallel output is performed using the set method in the same way in which a bar code matching the preset data is read. Check whether parallel output is performed normally. The counter value is increased.

PRESET

5 TIM 1 TIM 2

DEF 1 2 3 4 5

4 3 2 1

(

OUT

2 )

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

KEYENCE

ENTER

PROGRAM MONITOR

Data set to this preset No. Parallel output

40

BL-V35E

Page 51

Chapter 4

Basic Functions

Note: While the counter function is used, counting is performed even when the [ENTER] key is pressed. Verification continues using the next preset data. ■ Confirming the preset data In RUN mode, the contents of the preset data can be confirmed.

Procedure 1. Select a preset No. to be checked. Press the ▼ or ▲ key or press the [PRESET No.] key, and then select a preset No. whose contents are to be checked.

PRESET

TIM 1 TIM 2

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

4

2. Check the contents displayed on the LCD display. The preset data saved in the selected preset No. is displayed on the LCD display. The preset data is displayed.

PRESET

5 TIM 1 TIM 2

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

DE F 1 2 3 4 5

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

Note 1: When the [ENTER] key is pressed at this time, parallel output is performed. Note 2: When the reference data function is set, the data to be referenced is displayed.

41

Page 52

Chapter 4

Basic Functions

4.1.8 Counter function The counter function is used to count the number of times the data read by a bar code reader has matched the preset data in RUN mode. Up to 999,999 matches can be counted for each preset No. ■ Setting the counter function Procedure 1. Select set mode. Press and hold the [0] key for 2 seconds to select set mode.

PRESET

TIM 1 TIM 2

B L - V 3 5

PREEST No.

DATA

SHIFT ABC..

OPTION

7

8

4

5

RUNMo d e

4 3 2 1

S e t u p

OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

4 2. Display the main setting menu. Press the ▼ or ▲ key to select “3) Main”. Press the [ENTER] key.

PRESET

TIM 1 TIM 2

1 ) Po r t 1 3 ) Ma i n

4 3 2 1 OUT

2 ) Po r t 2 4 ) Op t i o n

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

1 PRESET

CANCEL

2

1

2

ENTER

0

CLEAR

PROGRAM

MONITOR

KEYENCE

3. Display the counter setting menu. Press the ▼ or ▲ key to display the counter setting menu, and press the [ENTER] key. “_” is displayed in the lower line. 05 0 )

Coun t e r OF F

4. Set the counter function. When the ▼ key is pressed, “0) ON” is displayed to indicate that the counter function is valid. When the ▲ key is pressed, “1) OFF” is displayed to indicate that the counter function is invalid.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

05 0 )

Co u n t e r ON

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

Counter function OFF Counter function ON

42

Page 53

Chapter 4

Basic Functions

5. Exit set mode. When the [ENTER] key is pressed once, the setting currently displayed is saved and the main setting menu is displayed again. Press the [CANCEL] key twice to exit set mode.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

21 PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

This completes setting of the counter function. ■ Operation of the counter function When the counter function is on, the LCD display format is changed. The data read by a bar code reader is displayed in the upper line, and the counter value corresponding to the data is displayed in the lower line. Readout data

4

ABC1 2 3 4 5 (

5 )

Counter value

Note 1: Data not matching the preset data is added to the counter value for preset No. 0. Note 2: Because the counter value is displayed, up to 24 digits of the bar code data is displayed. ■ Entering the counter value In RUN mode, any value can be entered as the counter value.

Procedure 1. Press the ▼ or ▲ key or press the [PRESET No.] key, and then select a desired preset No. • If a preset No. is not selected, the data currently displayed on the LCD display is to be changed.

PRESET

5 TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

43

Page 54

Chapter 4

Basic Functions 2. Press the [COUNT] key. When the [COUNT] key is pressed, the LED above it illuminates and “_” appears below the counter value displayed on the LCD display. Enter any value using the numeric keypad. • When the [CLEAR] key is pressed, the current counter value or a entered number is deleted. •

When the [BACK SPACE] key is pressed, one digit at the right end is deleted. The counter value can be changed.

Deletes the last character of the counter value.

PRESET

5 TIM 1 TIM 2

DEF 1 2 3 4 5

4 3 2 1

(

OUT

5 )

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

2

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

1

BL-V35E

Clear the current counter value.

3. Save the entered value.

4 key is pressed, the LED above the [COUNT] key turns off and When the the entered counter value is saved.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

This completes changes to the counter value. ■ Resetting the counter value The counter value can be reset at any of the following times. •

When the power is turned off

•

When the preset data is updated

In the BL-V35E, reset or hold can be selected at any of the above times. The interval at which the counter value is to be reset should be set in main set mode. The operating procedure in main set mode is described in Chapter 7 (➮ See p. 92).

44

Page 55

Chapter 4

Basic Functions

4.1.9 Parallel output form Parallel output is performed in the form of a bit, binary value or BCD number. The parallel output form can be set in main set mode (See p. 92). When the preset-active function or the serial No. check function is used, only verification OK (OUT1) or verification NG is output. •

Bit 1 OUT1 to 10

•

When verification is OK, outputs from OUT1 to OUT10 corresponding to the output Nos. 1 to 10 are turned on. When verification is NG, all outputs are turned off.

3

OK

When verification is OK, this output is turned on.

NG

When verification is NG, this output is turned on.

Binary value of BCD number 2

When verification is OK, the output No. (1 to 399) is output in a binary value or BCD number. When verification is NG, “0” is output.

OUT1 to 10 3 OK

When verification is OK, this output is turned on.

NG

When verification is NG, this output is turned on.

1, 2: Set the duration in “Out ON Timer” in the option set mode (➮ See p. 96). The setting range is from 10 ms to 2.55 s. It is set to 500 ms at the time of shipment. 3: Set the duration in “Out Delay” in the option set mode (➮ See p. 96). The setting range is from 0 to 255 ms. It is set to 5 ms at the time of shipment.

Example In the case of output No. 235 • Binary value OUT

10

9

8

7

6

5

4

3

2

1

ON/OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

ON

ON

• BCD number OUT

10

9

8

7

6

5

4

3

2

1

ON/OFF

ON

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

ON

10 to 9: 100’s digit 8 to 5: 10’s digit 4 to 1: 1’s digit Note: In the case of bit output, only up to 10 data (output Nos. 1 to 10) can be output even if 11 or more data presets have been saved.

45

4

Page 56

Chapter 4

4.2

Basic Functions

Preset-active Function This section describes the function for selecting from the saved preset data and checking whether it matches the readout data.

4.2.1 Preset-active function The multi-preset function checks whether the readout data matches any of the preset data. In the preset-active function, the readout data is checked against only a single selected preset data. Accordingly, only OK or NG is given as parallel output.

4.2.2 Using the preset-active function The preset-active function can be used for the following tasks. 1. Saving the preset data 2. Setting the preset-active function 3. Selecting the preset data to be used for verification

4

4. Reading a bar code Before using the preset-active function, save the preset data. The preset data entry procedure is described in “Multi-preset function” (See p. 33). Even when the preset-active function is used, new preset data can be saved, and the saved contents can be deleted or modified. ■ Setting the preset-active function Procedure 1. Select set mode. Press and hold the [0] key for 2 seconds to select set mode.

PRESET

TIM 1 TIM 2

BL - V35

RUN mo d e Se t up

4 3 2 1 OUT

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

2. Display the main setting menu. Press the ▼ or ▲ key to select “3) Main”. Press the [ENTER] key.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

1 ) Po r t 1 3 ) Ma i n

2 ) Po r t 2 4 ) Op t i o n

PRESET No.

DATA

SHIFT ABC..

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

1 1 PRESET

KEYENCE

46

CANCEL

2 2

1

2

ENTER

0

CLEAR

PROGRAM

MONITOR

Page 57

Chapter 4

Basic Functions

3. Set the operation mode. Ensure that “01 Mode Setup” is displayed, and then press the [ENTER] key. “_” is displayed below the item No. in the lower line. 01 0 )

Mo d e S e t u p No r ma l

4. Set the preset-active function. Press the ▼ or ▲ key to display “1) Active” in the lower line. Then, press the [ENTER] key to save the selection.

PRESET

PRESET

DATA

No. SHIFT ABC..

TIM 1 TIM 2

0 1

Mo d e

4 3 2 1

1 )

Ac t i ve

OUT

OPTION

Se t up 7

8

4

5

8 7 6 5 OK 10 9 NG

1 PRESET

2

1

2

ENTER

0

CLEAR

PROGRAM

MONITOR

CANCEL

KEYENCE

4

5. Exit set mode. Press the [CANCEL] key twice to exit set mode.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PRGRAM MONITOR

BL-V35E

This completes setting of the preset-active function.

47

Page 58

Chapter 4

Basic Functions

4.2.3 Selecting the preset data to be verified in the preset-active function Select the preset data to be verified in the preset-active function. The preset data can be selected using the [PRESET] key or the [ENTER] key. ■ When using the [PRESET] key You can select the preset data while looking at the preset No.

Procedure 1. Press the [PRESET] key. The preset LED illuminates, and the preset data corresponding to the current preset No. is displayed on the LCD display.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

SHIFT ABC..

OPTOIN

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

4

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

2. Select a preset No. Press the ▼ or ▲ key to display a desired preset No. You can also specify a desired preset No. directly by pressing the [PRESET No.] key. • When you have used the [PRESET No.] key to specify a preset No., press after using the numeric keypad so that the specified No. is saved. the

PRESET

3 TIM 1 TIM 2

49123456

4 3 2 1 OUT

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

1

2

0

CLEAR

PROGRAM

MONITOR

3. Press the [PRESET] key. When the [PRESET] key is pressed, the preset LED turns off.

This completes selection of the preset data to be verified.

48