Page 55

Appendices

This chapter provides the specifications, the dimensions, the list of settings, and information about replacing the communication cable.

A-1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .A-2 A-2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4 A-3 ASCII Code Table. . . . . . . . . . . . . . . . . . . . . . . .A-6 A-4 Settings and the Factory Default Values . . . . .A-7

A-1

Appendices

A-5 Replacing the Communication Cable . . . . . .A-14

Page 56

A-1

Specifications z General specifications Model

BL-N70VE

BL-N70UBE

BL-N70RE

BL-N70RKE

Interface

Keyboard interface

USB

RS-232C

RS-232C* For connection to Keyence products

Mini DIN 6-pin

USB (A type)

Connector shape Light source

D-Sub 9-pin (male)

Visible light semiconductor laser (Wavelength 650 nm) Output

40 μW

Pulse width

1.5 ms

Class

Class 1 (IEC 60825-1)

Reading distance

See the characteristic range for reading below.

Reading width

See the characteristic range for reading below.

Minimum resolution

0.125 mm or more

PCS

0.35 or more

Scan rate

72 scans per second UPC(A,E)/EAN, CODE39, CODE128/EAN128, CODABAR, CODE93, ITF, 2of5, GS1 Databar Omnidirectional, GS1 Databar Truncated, GS1 Databar Stacked, GS1 Databar Stacked Omnidirectional, GS1 Databar Limited, GS1 Databar Expanded, GS1 Databar Expanded Stacked

Supported code

Number of digits for reading

3 to 40 digits (80 digits with CODE128: CODE C)

Ambient light Appendices

Environmental resistance

Ambient temperature

0 to 40 ºC (32 to 104º F)

Ambient humidity

Rating

4800 lx

35 to 85% RH (No condensation)

Operating atmosphere

No dust or corrosive gas

Power supply voltage

5 V DC ±5%

Current consumption

200 mA or less

EMI

EN55022 Class B

Weight

Approx. 101 g

An AC adapter is included for BL-N70RE. The power supply voltage for the included AC adapter is 125 V AC ±10% (6 VA). BL-N70RE does not comply with the requirements on CE Marking.

z Interface specifications ‹USB

A-2

USB version

Ver 1.1

Compliant OS

Windows 98, 2000, XP, Vista

Format of sent data

Same as data sent from keyboard

Page 57

A-1 Specifications

‹Keyboard Compliant languages

106 Japanese, 101 English

Keyboard input cannot be accepted while reading the barcode

‹RS-232C Synchronization method

Start-stop synchronization

Transmission code

ASCII code

Baud rate

300, 600, 1200, 2400, 4800, 9600, 19200, 38400 bit/s

Data length

7/8 bit

Parity check

None/Even/Odd

Stop bit

1/2 bit z Reading range characteristics (typical) (units: mm)

Code type

Code type

Narrow bar width

Reading distance

A

CODE39

0.125

53

B

CODE39

0.19

83

C

CODE39

0.25

104

D

CODE39

0.66

178

0

50

100

150

200

Appendices

Reading distance (mm) 100

0 A B

100

C D

Reading width (mm)

‹Measurement condition • Measured using the Keyence standard barcode • Ratio of narrow bar to wide bar = 1:2.5 • Skew • Pitch • Tilt

: 15°

: 0° : 0°

A-3

Page 58

A-2

Dimensions z BL-N70 Series

(units: mm)

63

40

169

31

35 z AC adapter

(units: mm)

Appendices

40.5 1

Cable length 1.8 m

A-4

70 1

50 1

Page 59

A-2 Dimensions z Stand

(units: mm)

‹OP-77470

65

140

35 z Replacement cables ‹OP-77466

‹OP-77467 Cable length 2m ( 50mm)

Appendices

380mm 30mm)

Cable length 2m ( 50mm)

4.6 0.1

4.6 0.1

( 30mm)

‹OP-77468

‹OP-77469 Cable length 2m ( 50mm)

380mm ( 15mm)

4.7 0.1

Cable length 2m ( 50mm)

4.7 0.1

A-5

Page 60

A-3

ASCII Code Table First 4 bits Hexadecimal Binary

Last 4 bits

Appendices

A-6

0

1

2

3

4

5

6

7

0000

0001

0010

0011

0100

0101

0110

0111

DLE

(SP)

P

@

P

` p

!

Q

A

Q a q

R

B

R b r

0

0000

1

0001

SOH

DC1

2

0010

STX

DC2

3

0011

ETX

DC3

#

S

C

S c s

4

0100

EOT

DC4

$

T

D

T d t

5

0101

ENQ

NAK

%

U

E

U e u

6

0110

ACK

SYN

&

V

F

V f v

7

0111

BEL

ETB

W

G

W g w

8

1000

BS

CAN

(

X

H

X h x

9

1001

HT

EM

)

Y

I

Y i y

A

1010

LF

SUB

:

Z

J

Z j z

B

1011

HM

ESC

;

[

K

[ k

{

C

1100

CL

FS

<

¥

L

\ l

|

D

1101

CR

GS

=

]

M

] m

}

E

1110

SO

RS

>

^

N

^ n

~

F

1111

SI

US

?

̲

O

_ o del

Page 61

A-4

Settings and the Factory Default Values

Barcode symbology settings Highlighted items indicate factory defaults. Setting item

Setting content

UPC/EAN

ON (Enabled) OFF (Disabled)

CODABAR

ON (Enabled) OFF (Disabled)

CODE39

ON (Enabled) OFF (Disabled)

ITF

ON (Enabled) OFF (Disabled)

2of5 (Standard 2of5)

ON (Enabled)

CODE93

ON (Enabled)

OFF (Disabled)

OFF (Disabled) CODE128

ON (Enabled) OFF (Disabled) Appendices

GS1 Databar Omnidirectional

ON (Enabled) OFF (Disabled)

GS1 Databar Limited

ON (Enabled) OFF (Disabled)

GS1 Databar Expanded

ON (Enabled) OFF (Disabled)

A-7

Page 62

A-4 Settings and the Factory Default Values z Detailed symbology settings Setting item UPC/EAN

Setting content EAN13

ON (Enabled) OFF (Disabled)

EAN8

ON (Enabled) OFF (Disabled)

UPC-A

ON (Enabled) OFF (Disabled)

UPC-E

ON (Enabled) OFF (Disabled)

Extended UPC-A

Send 12 digits Send 13 digits

UPC-E settings

System code 0 omitted System code 0 added

Handling Supplementals

2 digit add-on enabled 2 digit add-on disabled 5 digit add-on enabled 5 digit add-on disabled

Appendices

Reading the Supplemental codes only

ON (Enabled)

Check digit

Send the UPC-A check digit

OFF (Disabled)

Do not send the UPC-A check digit Send the UPC-E check digit Do not send the UPC-E check digit Send the EAN 8 digit check digit Do not send the EAN 8 digit check digit Send the EAN 13 digit check digit Do not send the EAN 13 digit check digit CODE128 (EAN128)

EAN128

ON (Enabled) OFF (Disabled)

Sending ]c1

Send Do not send

Group separator

[GS] [SPC]

Highlighted items indicate factory defaults.

A-8

Page 63

A-4 Settings and the Factory Default Values

Setting item CODE39

CODABAR

ITF

Setting content Start/stop character transmission

ON (Enabled)

Check digit transmission

ON (Enabled)

Start/stop character transmission

ON (Enabled)

Start/stop character lower case/ upper case

Lower case

Check digit inspection

MOD16 enabled

Check digit transmission

ON (Enabled)

GS1 Databar Expanded

OFF (Disabled)

OFF (Disabled)

OFF (Disabled)

Upper case

MOD16 disabled

OFF (Disabled) ON (Enabled) OFF (Disabled)

Check digit transmission

ON (Enabled)

Check digit transmission

ON (Enabled)

Application identifier

Send

Symbology identifier

Send

Check digit transmission

ON (Enabled)

Application identifier

Send

Symbology identifier

Send

Symbology identifier

Send

OFF (Disabled) Appendices

GS1 Databar Limited

OFF (Disabled)

Check digit inspection

Check digit inspection

GS1 Databar Omnidirectional

ON (Enabled)

OFF (Disabled)

Do not send

Do not send

OFF (Disabled)

Do not send

Do not send

Do not send

Highlighted items indicate factory defaults.

A-9