The text of a manual · part 8 of 10
Hand-held Laser Barcode Reader BL-N70 Series User's Manual: 4 Programming BL-N70 Settings, pages 47 to 54
Pages 47 to 54 of 72, from Hand-held Laser Barcode Reader BL-N70 Series User's Manual
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-N70
Page 47
4-7 Digit Limit Function Settings
‹Limit #3 settings
Limit #3, digit settings
Limit #3, symbology settings
‹Limit #4 settings
Limit #4, digit settings
Limit #4, symbology settings
‹Limit #5 settings
4 Limit #5, digit settings
Limit #5, symbology settings
Limit #6, digit settings
Limit #6, symbology settings
‹Limit #7 settings
Limit #7, digit settings
Limit #7, symbology settings
4-19
Programming BL-N70 Settings
‹Limit #6 settings
Page 48
4-8
Communication Data Format Settings
Data format z Header To set the header to "None", set "STX disabled" and "TAB disabled."
4
STX enabled
<STX disabled>
TAB enabled
<TAB disabled>
Programming BL-N70 Settings z Symbol identifier
ON
<OFF> z Terminator To set CR + LF, set both "CR enabled" and "LF enabled." Do not set two or more options to "enabled" except to set the CR + LF combination mentioned above.
4-20
<CR enabled>
CR disabled
LF enabled
<LF disabled>
Page 49
4-8 Communication Data Format Settings
TAB enabled
<TAB disabled>
ETX enabled
<ETX disabled>
Inter character delay settings
<1 ms>
4
10 ms
Programming BL-N70 Settings
25 ms
4-21
Page 50
4-9
Communication Interface Settings
Keyboard/USB settings
JAPANESE
<USA>
RS-232C settings z Baud rate
4 Programming BL-N70 Settings
38400 bit/s
19200 bit/s
<9600 bit/s>
4800 bit/s
2400 bit/s
1200 bit/s
600 bit/s
300 bit/s z Data length
8 bits
4-22
<7 bits>
Page 51
4-9 Communication Interface Settings z Stop bit length
<1 bit>
2 bits z Parity check
No parity
Odd
4
<Even>
Programming BL-N70 Settings z Communication protocol To set the header to no protocol, set "RTS/CTS disabled" and "ACK/NAK disabled."
RTS/CTS enabled
<RTS/CTS disabled>
ACK/NAK enabled
<ACK/NAK disabled>
4-23
Page 52
4-10 Decimal Program Code Use these barcodes to set the laser off time for trigger switch operation mode ( page 413), reread prevention time ( page 4-16), the number of digits for the limit read digits function, and when setting the code type ( page 4-17). After reading the barcode to start the settings for each parameter, scan three numbers to perform the setting. • Read the first decimal program code : The buzzer sounds once. • Read the second decimal program code : The buzzer sounds twice. • Read the third decimal program code
: The buzzer sounds three times.
0
1
2
3
4
5
6
7
8
9
4 Programming BL-N70 Settings
4-24
Page 53
4-11 Symbology List Use these codes when setting the individual limits for the digit limit function ( page 4-17). Code type
Setting value
UPC-A
004
UPC-E
002
EAN-8 digits
003
EAN-13 digits
005
CODE39
080
CODABAR
081
ITF
082
CODE128
083 084
GS1 Databar Omnidirectional GS1 Databar Stacked GS1 Databar Stacked Omnidirectional GS1 Databar Truncated
101
GS1 Databar Limited
102
GS1 Databar Expanded
103
4 Programming BL-N70 Settings
CODE93
4-25
Page 54
4-11 Symbology List
MEMO
4 Programming BL-N70 Settings
4-26