Page 54
Chapter 3
Functions for Reading Operation
3.4.3 Online test mode When the BL-700 always reads the bar codes, the reading stability can be displayed in real time using the STABILITY LEDs. This mode is called online test mode. ■ Setting 1. To set the online test mode, send the following command from the BL setup software terminal. To use the terminal, see P.77. Command to be sent: #TEST1 Send-data: OK When OK is returned to the command sent, it indicates the mode is set. This setting is valid only when power is ON. The setting data is reset after power is turned OFF. 2. According to the setting, start the BL-700 to read bar codes normally. In the online test mode, the send-data and STABILITY LEDs are displayed after the trigger input turns OFF. 3. The STABILITY LEDs turn ON as shown below, indicating how many times the unit can read the data correctly. Reading rate
STABILITY LED
100 or more
5 LEDs ON
50 to 99
4 LEDs ON
10 to 49
3 LEDs ON
5 to 9
2 LEDs ON
1 to 4
1 LED ON
0
–
4. The BL-700 sends the data in the following format. The information on the scan count during one trigger-ON and the correct readout count is appended to the data. The scan count includes the cases where no bar code is set. Delimiter Readout data
:
m
/ s
* m = 1 to 9999: Readout count (zero-suppressed) s = 1 to 9999: Scan count (zero-suppressed)
5. To quit the online test mode, send the following command. Command to be sent: #QUIT Send-data: OK When OK is returned to the command sent, it indicates the mode is canceled. Tips
Online test mode operation is the same as when setting the following from the BL-700 setup software. To save the online test mode setting in the BL-700, set the following using the setup software. • Data adding function, Add decode count. Add scan count. • STABILITY LED, Display the data. Note: When you try to enter the test mode by turning on trigger input, you cannot use the serial command to enter the test mode. Commands should be entered in all uppercase characters.
41
3
Page 55
Chapter 3
3.5
Functions for Reading Operation
STABILITY LEDs STABILITY LEDs allow you to easily check reading stability and operation status.
Indication of reading stability ■ When reading rate check mode is selected STABILITY LEDs light according to the reading rate shown in the table below. Although, in the test mode, the unit does not output an OK/NG signal, the OK/NG LED lights as below. (Comparison to the preset data is not performed.) Reading rate
3
STABILITY LED
OK/NG LED
81 to 100%
5 LEDs light
Green
61 to 80%
4 LEDs light
Green
41 to 60%
3 LEDs light
Green
21 to 40%
2 LEDs light
Green
1 to 20%
1 LED light
Green
0%, Red
■ When tact check mode is selected STABILITY LEDs light according to the scan count (decode count), which indicates the number of successful reads, as shown in the table below. Although, in the test mode, the unit does not output an OK/NG signal, OK/NG LED lights as below. (Comparison to the preset data is not performed.) Decode count
STABILITY LED
100 or more
5 LEDs light
50 to 99
4 LEDs light
10 to 49
3 LEDs light
5 to 9
2 LEDs light
1 to 4
1 LED light
0, OK/NG LED Green (decode counts are equal to or greater than the preset match count) Red (decode counts are less than the preset match count) Red
■ When normal read mode is selected When you select multi-label read mode 1 or 2 (➮ See P.33 to 34), or the send mode is set to “after trigger input” (➮ See P.32 ), or you select the decode count adding function (➮ See P.47), STABILITY LEDs light according to the decode count as shown in the table below. However, If you do not select “use STABILITY LED” in the setup software (➮ See P.68), STABILITY LEDs do not light in normal read mode. ON/NG output (ON/NG LED) turns on/off normally according to the result of a comparison to the preset data. The following also appears in the online test mode.
42
Decode count
STABILITY LED
100 or more
5 LEDs light
50 to 99
4 LEDs light
10 to 49
3 LEDs light
5 to 9
2 LEDs light
1 to 4
1 LED light
0
Page 56
Chapter 3
Functions for Reading Operation
■ Unit operation status display STABILITY LEDs indicate the following information in addition to reading stability. Operation status
STABILITY LED display
Action to be taken
Power-on
LEDs turn on sequentially from the bottom.
During setup (➮ see P.92)
All the LEDs flash.
Waiting for setting data send/receive (➮ see P.73)
The 1st, 3rd and 5th LEDs from the top flash simultaneously.
In this status, send the settings from the setup software. (Hold down the TEST switch for 8 seconds to set the data.)
Laser forced OFF (➮ with LOCK command, see P.90)
The bottom LED flashes.
When resetting laser forced OFF (with UNLOCK command), the unit returns to the initial operation at power-on.
Unit error
Either of the 2nd, 3rd, or 4th LEDs from the top flashes.
The unit may have failed or supply voltage may have dropped. If supply voltage is normal, the unit may have failed. Contact the nearest KEYENCE office or distributor.
PLC link error (➮ see P.117)
The top LED flashes.
The error is reset by pressing the TEST switch again. ➮ See P.116 for troubleshooting.
43
3
Page 57
Chapter 3
3.6
Functions for Reading Operation
Preset Function (Compare with:)
3.6.1 What is the preset function? The BL-700 can store one bar code as preset data. It compares the preset data to the bar code data actually read and outputs an OK/NG signal to whether there is a match. Using the BL-700 preset function, you can prevent the wrong products from entering the line without using a PC. If no preset data is registered, the unit outputs OK when it successfully reads a bar code and NG when it fails to read a bar code. ➮
See P.30 to 37 for output timing.
Use the setup software and serial command to register the preset data (➮ See P.68 and P.101).
3
Note: The bar code actually read can be compared to the preset data only in the single label read mode. ➮ See P.136 if you want to use CODE93. ➮ See P.137 if you want to use CODE128.
44
Page 58
Chapter 3
Functions for Reading Operation
3.6.2 Wildcard Symbols (“!” and “?”) Using “!” and “?” in the preset data allows for flexible settings. ?: Does not define numeric values (characters) of certain digit(s) of the bar code. !: Ignores numeric values and symbols within the dot box and recognizes the bar codes as the same group.
49123456 49125256 4912AB56
49123456 4912C 4 9 1 2
When using “?” data as “4912??56”, 2 digits positioned in “??” can contain any numeric values (or characters), expanding the allowable range. Identifies all the bar codes to be OK as long as the beginning or ending strings match.
When using “!” as “4912!”, any bar code which begins with “4912” will be OK. When using “!” as “!4912”, any bar code which ends with “4912” will be OK.
3
Setting examples 1. “ABC?”
ABCD (OK),
ABC3 (OK), ABC (NG),
ABCDE (NG)
2. “ABC!”
ABCD (OK),
ABC3 (OK), ABC (OK),
ABCDE (OK),
AB (NB)
3. “?????”
Any 5-digit bar code will be OK.
4. “!CDE”
ABCDE (OK),
3CDE (OK), CDE (OK),
ABBDE (NG),
ADE (NG)
5. “A!E”
ABCDE (OK),
A3CE (OK), ABCD (NG),
AE (OK)
Note: You can use “!” only once in the setting. Tips
If you do not register preset data, “!” is automatically registered. Therefore, when the unit successfully reads a bar code, “OK” is output; when the unit fails to read, “NG” is output.
45
Page 59
Chapter 3
3.7
Functions for Reading Operation
Additional Information When sending the bar code data, you can add the following data to the readout data.
Additional information types ■ Decode match count add function Adds the number of successful scans during one bar code reading (decode count) to the end of the readout data (up to 9999 count). However, this decode count is never less than the preset decoding match count. This function can be used to check reading stability and code label quality. Delimiter
:
Readout data
3 d d = [Decoding match count] to 9999: Decode count
*
The value is zero-suppressed.
When using this function, output turns on at a different time from normal operation. •
In single label read mode, output turns on after one bar code has been read (after trigger input turns off). Even if you set the data send to “after read”, the data is forced sent after trigger input turns off.
•
In multi-label read mode 1, a bar code passes across the laser beam’s field, after repeat read time, and is finally output.
•
In multi-label read mode 2 or 3, operation is the same as when you do not use the decode match count adding function.
■ Scan count add function (valid only when using the read count add function) Adds the number of scans, including when no bar code exists, to the end of the decode count (up to 9999). Delimiter Readout data
:
d
/ s s = 1 to 999 (zero-suppressed)
*
46
The value is zero-suppressed.
Page 60
Chapter 3
Functions for Reading Operation
■ Code type add function Adds the bar code type before the readout data . Delimiter
:
Readout data t= 0 1 2 3 4 5 6 7 8
: CODE39 : ITF : Industrial 2of5 : Codabar : EAN/UPC (A•E) : CODE 128 : COOP 2 of 5 : Read error : CODE93 t
■ Label orientation add function Adds the orientation of bar code travel before the readout data. Delimiter
4 9000000
:
Readout data
*
BL-700 TEST
TIMING
OK/NG
LASER ON
: Forward : Reverse
STB r= F R
4 9000000 r
3
Forward Reverse orientation orientation
If an read error occurs, this information is not added.
Order of additional information If you select to include all the additional information functions, they appear in the following order: Code type
Tips
:
Label orientation
:
Readout data
Decode : match count :
Scan count
You can change the delimiter as desired (one character), except the delimiter of the scan count.
47
Page 61
Chapter 3
3.8
Functions for Reading Operation
Max. Code Length (Designated Digit ) Output Function This function allows you to output the designated digit(s) as desired from the readout bar code data. For example, from bar code data “49123456”, you can extract “1234” for output.
Setting digits to be output Set the digits to be output as shown below. Individually set the digits for codes 1 to 4. 1. Set the direction to designate. * Set from which direction you want to start counting. Forward
3
Reverse
4 9 1 2 3 4 5 6 2. Set how many digits you want to designate for output starting from the designation start digit in (2) (designation effective digits). 5th digit by counting forward
4 9 1 2 3 4 5 6 * The actual setting order is (1) (3) (2). 3. Set from which digit you want to begin designation (destination start digit). 3 digits starting from 5th digit by counting forward
4 9 1 2 3 4 5 6
Example Designating and outputting “34” from bar codes “158423421” and “58423421”
1 5 8 4 2 3 4 2 1
5 8 4 2 3 4 2 1
Designate 2 digits starting from 3rd digit by counting reversely. Tips
48
•
Regardless of the designated direction, the data is output forward in the communication application.
•
When the bar code group includes those having different digits, take special care on the designated direction when setting the digits to be output.
•
When comparing to the preset data, all the digits of the bar code are used.
Page 62
Chapter 4 Setup Software 4.1
Installing the Setup Software ............................................ 52
4.1.1 Installing setup software ........................................................ 52 4.1.2 Installation procedure ............................................................ 52 4. 2
Setup Software Operating Procedure ............................... 54
4.2.1 Operating procedure .............................................................. 54 4.2.2 Description on each setup screen ......................................... 55 4.2.3 Outline of operation ............................................................... 56 4.3
Details of Setup ................................................................... 58
4.3.1 Setup procedure .................................................................... 58 4.3.2 Reading/Saving/Printing File ................................................. 71 4.4
Sending/Receiving Settings .............................................. 75
4.5
Using Monitor ...................................................................... 79
4.6
List of Error Messages ....................................................... 82
4.7
Example of Printing from the Setup Software .................. 83
Page 63
Chapter 4
4.1
Installing the Setup Software
Installing the Setup Software This section describes the operating environment of the setup software and the software installation.
4.1.1 Installing setup software ■ Hardware requirements IBM PC/AT 100% compatible CPU: 486 SX or higher Memory: 4 MB or more Floppy disk drive: 3.5 inch floppy disk drive (1.44 MB compatible) Display: Resolution 640 x 480 or higher Serial port: A minimum of one RS-232C port is required. ■ OS requirements • MS-Windows 3.1 • MS-Windows 95
4
4.1.2 Installation procedure 1. Insert the BL-700 setup software system disk into the floppy drive. 2. Perform the following procedure.
50
•
Windows 3.1: Execute “Run...” in the icon menu of the program manager.
•
Windows 95: Select “Run” from the "Start" menu.