Page 64
Chapter 4
Installing the Setup Software
3. Run the “SETUP” file from the floppy disk drive. (This step is common to both the Windows 3.1 and Windows 95.) Type in as follows: A: \SETUP 4. The BL-700 setup software installer starts. Follow the instructions in the install window. (Typically, the installation procedure can be completed simply by pressing [Next (N)] twice.) 5. The setup software is normally installed in the following directory: C: \KEYENCE\BLSET If this directory is correct, click on [Next (N)]. If you wish to change the directory, click on [Browse (R)..], and select the desired directory. 6. When installation starts, the file copy process is displayed as a graph. When the installation is completed, the following message appears.
4
7. For Windows 3.1, double-click on the [BL] icon in the [KEYENCE] group to start the setup software. For Windows 95, start the program from the "Start" menu.
51
Page 65
Chapter 4
4.2
Installing the Setup Software
Setup Software Operating Procedure
4.2.1 Operating procedure To set up the BL using the setup software, follow the procedure below. 1. Connect the BL to the host computer using a null modem cable. For the recommended cable, see P. 12 and P. 19. 2. Start the BL setup software. 3. In “Select Model” of “File/etc...”, select the model to be connected (“BL-700”). 4. Select a setup item, and set it to the desired condition. 5. Before sending the updated settings to the BL-700, click on [COM PORT] to match the communication parameters of the personal computer with the current settings of the BL. The default settings of the BL are as follows: • Baud rate: 9600 bit/s • Data length: 7 bit • Parity: Even • Stop bit length: 1 bit • PLC link: Don’t use • Multi-drop link: Disabled
4
Immediately after you purchase the BL, set [COM PORT] to the above settings. If you do not know the current settings of the BL, press the BL TEST switch for approximately 8 seconds. The 1st, 3rd and 5th STABILITY LEDs from the top will flash simultaneously. The settings listed above are fixed. Execute (6) “Send/ receive settings”.
6. Click on [Transfer] to send the updated settings to the BL. (The current settings of the BL can also be read.) 7. Select [FILES] to save or print the settings, as required. 8. After the setup procedure is completed, click on [Exit] to close the setup software.
52
Page 66
Chapter 4
Installing the Setup Software
4.2.2 Description on each setup screen Displays the name of the setup file currently being edited. If the file has been read from the setup file, the file name is specified as “File: ...”. If the file has been read from the BL, the file name is marked with “BL”. If the file name is the initial setting, “default” is displayed. If the file name has been changed from the initial setting (the condition immediately after it is read from the file), “changed” is displayed.
Select the model to be set.
Main (Operation setting:) • Read mode and its setup • Data addition function • Decoding match count • Read error code • Scanning method, trigger ON/OFF command
4
Comm Settings-1 (Communication parameters 1:) • Baud rate, data length, parity, stop bit • RTS/CTS protocol • Multi-drop, ID number Comm Settings-2 (Communication parameters 2:) • Communication protocol • Header and terminator • PLC link settings • Delimiter, semi-delimiter Code setup (Bar code setting:) • Type of bar code to be read, number of digits • Fixed-digit output function, label orientation function Utilities: • OK/NG output ON time • Preset data registration Files...: Saving, readout and printout of settings, selection of model COM Port: Sets the communication parameters (baud rate, etc.) of the host computer according to the settings of the BL before communication starts between the BL and host computer. TRANSFER: Sends updated settings to the BL, or reads the current settings of the BL. MONITOR: Checks if the BL can operate normally. EXIT: Quits the BL setup software.
53
Page 67
Chapter 4
Installing the Setup Software
4.2.3 Outline of operation This section describes the basic operations of the BL setup software. To enter settings, place the mouse pointer on the item to be changed, and click the left mouse button.
▲
Mouse pointer
■ Clicking on • • • (tabs) Used to select the item to be changed.
4
• ■ Clicking on ● (radio button) Used to select any of several options. The selected item is marked with ● .
■ Clicking on a ■ (box) Used to select whether to enable or disable this function. To enable this function, the ■ mark is checked with “ ”. (For the Windows Ver. 3.1, it is checked with “x”.)
■ Clicking on ▼ (arrow) Used to select any of several options.
54
Page 68
Chapter 4
Installing the Setup Software
■ Entering a value After clicking in the frame, enter a value using the keyboard. If the entered value exceeds the setting range, an error message is displayed. ➮ See P.82.
■ Entering characters When you click in the frame labeled “ASC”, you can enter characters using the keyboard. When you click in the frame labeled “HEX”, you can enter characters using hexadecimal numbers (00 to 7F). This function is used to enter control characters (00 to 21h ASCII codes, such as [CR] and [STX]).
4
55
Page 69
Chapter 4
4.3
Installing the Setup Software
Details of Setup
4.3.1 Setup procedure Main (Operation setting) Set read mode, additional data function and trigger input.
4
1. When “Single” is selected in “Read Mode”, the following appears:
When “Multi 1” or “Multi 2” is selected, the following appears:
Set the data to a number from 1 to 255 (100 ms to 25.5 s). When “Multi 3” is selected, these setting menus will not appear. 2. Multiple data can be selected in “Additional data function”. “Scan count” appears only when “Decode count” is selected.
56
Page 70
Chapter 4
Installing the Setup Software
3. Enter the “Read error code” from the keyboard. The code can be changed as desired (within 8 characters). Normally, the initial setting (ERROR) should be used as provided. If a blank is specified for the setting, the BL-700 will not send the read error code. 4. Click “Trigger input setting” to set the trigger input. Tips
• • • • • •
Read mode ➮ P.35 to 38 Data transmission trigger ➮ P.34 Double reading prevention time ➮ P.35 to 36 Decoding match count ➮ P. 32 Additional data function ➮ P.48 to 49 Read error code ➮ P.89
Trigger input setting Set the trigger input, scanning method and trigger ON/OFF command.
4
1. For the scanning method, select either “Level signal trigger” or “One-shot signal trigger”. If “One-shot signal trigger” is selected, the scanning time setting menu also appears.
Set the scanning time to a number from 1 to 255 (100 ms to 25.5 s).
57
Page 71
Chapter 4
Installing the Setup Software 2. Enter the “Trigger ON/OFF command” from the keyboard. The command name can be changed as desired (within 8 characters). Normally, the initial setting (LON, LOFF) should be used as provided. 3. Enable either “Start the test mode with trigger input ON” or “Start the test mode at power-on”.
When “Start the test mode with trigger input ON” is enabled, the trigger input cannot be used during normal operation. If both functions are selected, “Start the test mode with trigger input ON” has priority. Tips
4
• • •
Scanning method ➮ P.32 to 33 Trigger ON/OFF command ➮ P.91 Starting the test mode ➮ P.40 to 43
Comm Settings-1 (Communication parameters 1) Set the communication parameters.
When “Multi-drop (RS-485)” is enabled, the ID number setup menu also appears. Set the ID number to a value from 1 to 31. “RTS/CTS protocol” is then disabled.
Tips
58
• •
RTS/CTS protocol ➮ P.88 Multi-drop ➮ See the Multi-drop Controller N-400 User’s Manual.
Page 72
Chapter 4
Installing the Setup Software
Comm Settings-2 (Communication parameters 2) The following settings depend on the use of “PLC link”. ■ When the PLC link is not used The menu screen allows setup of communication protocol, header and terminator.
1. Select the header and terminator from the items provided. When the header and terminator are set, only the read data format can be changed. When “Set” is clicked, the following menu appears:
4
Enter the desired data from the keyboard up to a maximum of 5 characters. 2. When “Character” is clicked, the following menu appears:
Enter the delimiter and semi-delimiter from the keyboard and then click [Return]. Tips
• • • • •
(Communication) protocol ➮ P.87 to 88 Header, terminator ➮ P.89 Checksum ➮ P.140 Delimiter character ➮ P.48 to 49 Semi-delimiter ➮ P.37 to 38
59
Page 73
Chapter 4
Installing the Setup Software ■ When using the PLC link To enable the "Use PLC", set each item as follows:
The setting of the station number is not displayed when “KV Series” is selected.
The setting of the file register is displayed only when “MELSEC-A” is selected.
4
•
Set “Connected PLC”, “DM head address” and “Station No.”. To set “DM head address”, enter a value (0000 to 9900) using the keyboard.
•
To send a trigger signal to the BL series when the PLC link is enabled, set “PLC trigger area”.
•
To use “File Register”, set “File Register” to “Enable”. When “File Register” is enabled, the following screen appears. The “File Register” can be used with the Mitsubishi MELSEC-A series only.
Enter the block number (000 to 255) of the file register using the keyboard.
Tips
60
• • • •
PLC link ➮ P.106 PLC trigger area ➮ P.113 to 115 DM head address ➮ P.111 File register ➮ P.107