The text of a manual · part 11 of 19
Laser Bar Code Reader BL-700 Series User's Manual: Chapter 1 Laser Safety Precautions, pages 74 to 83
Pages 74 to 83 of 161, from Laser Bar Code Reader BL-700 Series User's Manual
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-700, Keyence BL-701 and Keyence BL-781
Page 74
Chapter 4
Installing the Setup Software
Code Setup (Bar code setting) Set the readout digits, detail data and special functions for each code type.
1. Set the code. Set the type and number of digits of the bar codes to be read in codes 1 to 4. If four different types of codes are specified in 1 to 4, the BL-700 can read 4 types of bar codes without changing the settings. 2. Click [Details] to set “Send start/stop character” and “Check digit test”. 3. Click [Options] to set “Fixed-digit output function” and “Label orientation function” (➮ see P.69). *
Be sure to set the ITF digits to an even number.
*
For UPC/EAN, set whether each of the 13-digit EAN, 8-digit EAN and UPC-E is enabled to read.
*
CDE128 varies depending on the type of the start/stop character (CODE-A to CODE-C) CODE-A/B: 1 to 31 CODE-C: 1 to 64 The start/stop character and check digit are not included in the number of digits. Also, FUN 1 to 4 (function codes), SHIFT and CODE-A to CODE-C are not included in the number of digits.
61
4
Page 75
Chapter 4
Installing the Setup Software
CODE 39 detail settings When “CODE 39” is set for any of the 4 codes in the bar code setting and then [Detail] is clicked, the following screen appears.
1. When “Send start/stop character (*)” is set, the BL-700 adds an * (asterisk) to the data and sends it.
4
2. When “Check digit test” is set, the following appears:
When “Send check digit” is set, the BL-700 sends the data including the check digit. To calculate the check digit, the BL-700 uses Modulus 43.
62
Page 76
Chapter 4
Installing the Setup Software
ITF detail settings When “ITF” is set for any of the 4 codes in the bar code setting and then [Detail] is clicked, the following screen appears.
1. When “Check digit test” is set, the following appears:
4 When “Send check digit” is set, the BL-700 sends the data including the check digit. To calculate the check digit, the BL-700 uses Modulus 10/3 weight.
Tips
When reading the standard distribution code (bar code on the carton box), set 14 digits or 16 digits in the bar code setting and set “Check digit test”.
63
Page 77
Chapter 4
Installing the Setup Software
Codabar detail settings When “Codabar” is set for any of the 4 codes in the bar code setting and then [Detail] is clicked, the following screen appears.
1. When “Lowercase” or “Uppercase” is set in “Start/stop character”, the BL-700 adds “A, B, C, D” (lowercase or uppercase) to the data and sends it.
4
2. When “Check digit” is set, the following appears:
When “Send check digit” is set, the BL-700 sends the data including the check digit. Select the type of check digit to be used.
64
Page 78
Chapter 4
Installing the Setup Software
UPC/EAN detail settings When “UPC/EAN” is set for any of the 4 codes in the bar code setting and then [Detail] is clicked, the following screen appears.
1. “UPC-A output digits” sets whether the 13-digit or 12-digit output format is used when reading the UPC-A data. 2. When “Yes” is set in “Add UPC-E system code [0]”, the BL-700 adds 0 to the beginning of the system code and sends the code. (This parameter appears only when “UPC-E” is set to enable reading in the bar code setting.) *
The check digit setting is not provided on the screen but the BL-700 calculates it using the modulus 10/3 weight. (The data is sent.)
(Industrial) 2of5, COOP2of5 and CODE93 detail settings When “2of5”, “COOP2of5” or “CODE93” is set for any of the 4 codes in the bar code setting and then [Detail] is clicked, the following screen appears.
For industrial 2of5, COOP2of5, and CODE93, detail setting parameters are not provided.
65
4
Page 79
Chapter 4
Installing the Setup Software
CODE128 detail settings When “CODE128” is set for any of the 4 codes in the bar code setting and then [Detail] is clicked, the following screen appears.
1. “Double character start pattern” is defined in the UCC/EAN-128 standard. This is a combination of the start character (CODE-A to CODE-C) and FUN1 (function code 1). The UPC/EAN-128 bar code must start with the double character start pattern.
4
If this is not set, the BL-700 will not be able to read the data. *
66
The check digit setting is not provided on the screen but the BL-700 calculates it using the modulus 103 weight. (The data is not sent.)
Page 80
Chapter 4
Installing the Setup Software
Options setting When [Options] is clicked in the bar code setting, the following screen appears.
Set “Max code length output function” and “Label orientation function”. Tips
• •
Fixed-digit output function ➮ P.50 Label orientation mode ➮ P.39
4
67
Page 81
Chapter 4
Installing the Setup Software
Utilities settings The settings of OK/NG output ON time and preset data registration are available.
1. To set “OK/NG output ON time”, enter a numeric value from the keyboard from 1 to 255 (10 ms to 2.55 s). 2. When “Display STABILITY LEDs” is set, the BL-700 displays the STABILITY LEDs which indicate the reading stability during normal reading operation.
4
3. To set “Preset data”, enter the preset data to be registered from the keyboard. Normally, the data should be set within 32 characters. If CODE-C is set for CODE128, up to 64 characters can be set. Tips
68
• • •
OK/NG output ON time ➮ P.32 STABILITY LED ➮ P.44 Preset data ➮ P.46
Page 82
Chapter 4
Installing the Setup Software
4.3.2 Reading/Saving/Printing File The FILES screen is used to save updated settings in a file, to read a saved setting file, and to print the contents of a setting file.
4
•
Model: Select the model to be set.
•
Open: Reads a saved setting file.
•
Save: Saves updated settings in a file.
•
Compare: Compares the settings currently edited with a file previously saved.
•
Print: Prints contents of a setting file.
•
Defaults (Initialize settings): Restores updated settings to the default settings.
•
Version info: Displays the version information of this software.
Reading a previously saved setting file 1. To read a previously saved setting file, click on [Open]. The following screen will appear.
2. When you click on [OK] after selecting a file, the selected file can be opened.
69
Page 83
Chapter 4
Installing the Setup Software
Saving updated settings in a file 1. To save updated settings in a file, click on [Save]. The following screen will appear.
4
2. Click on the file name entry field, and enter a file name using the keyboard. Specify a file name within eight characters. Be sure to add the extension “NCF”. After entering the file name, click on [OK] to save the file.
Note: This software cannot accept a long file name in Windows 95.
Tips
70
When the saved setting file is sent to the BL-700, the name of the file is simultaneously sent to the BL-700. When you read the settings of the BL-700 using this software, the file name is also read. It is convenient for maintenance since you can find the file that stores the settings. To enter a file name, use alphanumerics (letters and numbers) only. Otherwise, the file name cannot be sent to the BL-700, because it can only recognize alphanumerics. To send a file name, be sure to enter the file name using alphanumerics and then save it. (If the file name is not saved, it cannot be sent to the BL-700.)