Page 44

Chapter 3

Functions for Reading Operation

■ One-shot signal trigger The unit detects the rising edge of the trigger input and starts reading bar codes for the preset input time. The laser beam turns off after reaching the specified decode count and the unit sends the readout data. The remaining actions are the same as those for level signal trigger.

Trigger input

<Succeed to read> *1

<Fail to read>

Bar code Preset input time

Preset input time

Laser beams Communication time OK/NG output

OK/NG

NG

3

1. After the trigger input exceeds the preset input times, the laser begins to emit. Trigger input minimum ON time: 4 ms (when the trigger input value is 2 ms) 13 ms (when the trigger input value is 10 ms) Tips

•

The BL-700 can read up to 4 types of bar codes without changing the bar code type setting (➮ see P.61).

•

For general operation, see “Level signal trigger” Choose “One-shot signal trigger” when the trigger input signal is very short or you want to set the input time.

•

To use a one-shot trigger signal instead of trigger input, gently press the TEST switch once (for less than 3 seconds) (➮ see P.vi).

NOTE: The BL-700 has a built-in AGC (auto gain control) circuit. It requires a maximum of 3 scans (4.3 ms) to adjust gain. The BL-700 generates a maximum of 4.3 ms delay until starting to read the data after the laser beam turns ON.

31

Page 45

Chapter 3

Functions for Reading Operation

3.1.2 Data-send mode In the single label read mode only, you can select from the two data send modes (OK/NG output on trigger) described below: In the multi-label read mode, you can only select the “send after reading” mode. • Send after read The unit outputs the communication and OK/NG signals after a successful read (trigger output turns on as many times as the preset decode count). This is the same operation as in the time chart described in “3.1.1 Scanning method”. Normally, this is the method you should use. • Send at trigger input The unit outputs the communication and OK/NG signal when the trigger input turns off (or the preset input time has passed if one-shot signal trigger is selected).

3 <Fail to read>

<Succeed to read> Trigger input Bar code Laser beams Communication time OK/NG output

32

OK/NG

NG

Page 46

Chapter 3

3.2

Functions for Reading Operation

Read Modes The BL-700 provides 4 types of read modes.

3.2.1 Single label read mode This mode allows the unit to read one bar code during one trigger input signal. The operation and timing chart are described on page 30 to 32.

3.2.2 Multi-label read mode 1 (Multi 1) This mode allows the unit to read several bar codes printed on one label as shown below during one trigger input signal. The unit outputs the readout data sequentially.

3 R ON LASE STB

G OK/N G TIMIN

TEST

BL-700

Multi-label read mode 1 operation <Succeed to read>

<Fail to read>

Trigger input Repeat reading time Bar code Laser beams Communication time OK/NG output

OK

OK

OK

OK

NG

•

In the multi-label read mode 1, the unit reads several bar codes continuously, and outputs them sequentially as it reads while laser beam remains on and trigger input turns on after bar codes have been read (or during the preset input time if one-shot signal trigger is selected).

•

To prevent the unit from reading the same bar code twice, the time for one bar code to pass across the laser beam’s field and read, plus the repeat reading time must be set (100 ms to 25.5 s). During the repeat reading time, the unit cannot read the same bar code repeatedly, but can read different bar codes.

•

A reading error is issued only when the unit cannot read any bar code while the trigger input is on.

•

For OK/NG output, “OK” turns on every time the unit reads a bar code and “NG” turns on if the unit fails to read a bar code. (Comparison to the preset data is not performed.)

33

Page 47

Chapter 3

Functions for Reading Operation

3.2.3 Multi-label read mode 2 (Multi 2) As with multi 1 mode, this mode allows the unit to read several bar codes continuously while the trigger input is on. (The number of bar codes that can be read depends on the buffer capacity. See P.86.) The difference between the two modes is that multi 2 mode sends all the readout data at one time after the trigger input turns off.

Multi-label read mode 2 operation <Succeed to read> Trigger input

<Fail to read>

Repeat reading time

Bar code

1 2 3 4 5 Laser beams

3

Communication time 12345 OK

OK/NG output

NG

•

Multi 2 mode allows the unit to read several bar codes while the trigger input is on (or during the preset input time if one-shot signal trigger is selected) and sends all the readout data at one time after the trigger input turns off (or after the preset input time is expired if one-shot signal trigger is selected).

•

To prevent the unit from reading the same bar code twice, the time for one bar code to pass across the laser beam’s field and read, plus the repeat reading time must be set (100 ms to 25.5 s). During the repeat reading time, the unit cannot read the same bar code repeatedly, but can read different bar codes.

•

A reading error is issued only when the unit cannot read any bar code while the trigger input is on.

•

For OK/NG output, after trigger input turns off, “OK” turns on if the unit reads at least one bar code and “NG” turns on if the unit fails to read a bar code. (Comparison to the preset data is not performed.)

Reading data format Header

34

1st data

,

2nd data

,

3rd data

,

4th data

,

•••••••

Delimiter

•

Each data packet is separated by a comma (, : 2CH) (intermediate delimiter).

•

The unit sends as many data packets the number of bar codes read.

➮

See P.87 for “header string” and “delimeter”.

Page 48

Chapter 3

Functions for Reading Operation

3.2.4 Multi-label read mode 3 (Multi 3) As described in multi-label read modes 1 and 2, this mode also allows the unit to read several bar codes (up to 4 codes) while the trigger input is on. The unit sends the readout data at one time according to a specified sequence after the trigger input turns off. When up to 4 codes are in the laser beam’s field, the unit can simultaneously reads all of them.

Operation of multi-label read mode 3 This mode allows the unit to continuously read each one of 4 bar code types “Code 1”, “Code 2”, “Code 3”, and “Code 4” as specified in the “code setup” of the setup software (➮ see P.61). If 3 types are specified in the “code setup”, the unit reads 3 bar codes (each of 3 types). If 2 types are specified, the unit reads 2 bar codes. The following time chart is given.

3 Trigger input Bar Code

Code 1 Code 2 Code 3 Code 4

Laser beams Code 4

Code 3

Code 2

Code 1

Communication time

OK

OK/NG output

NG

*

The above example chart is with all 4 codes specified in the “code setup” of the setup software.

•

The bar code reading sequence is not fixed.

•

The unit communicates the readout data in the order of Code 1 to Code 4. After the trigger input turns off, the unit sends all the data at one time.

•

For OK/NG output, “OK” turns on if the unit reads all the specified Codes 1 to 4 and “NG” turns on if the unit fails to read at least one bar code. (Comparison to the preset data is not performed.)

Reading data format

Data read

Header from Code 1

Data read

Data read

Data read

2

3

4

, from Code , from Code , from Code Delimiter

•

Each data packet is separated by a comma (, : 2CH) (intermediate delimiter).

•

If an read error occurs on any one of Codes 1 to 4, or the corresponding bar code does not exist, “ERROR” (➮ see P.87 for the reading error codes), instead of the read data is sent.

➮

See P.87 for “header string” and “delimeter”.

35

Page 49

Chapter 3

Functions for Reading Operation Example Suppose that the following codes are specified: Code 1: CODE39, 10 digits Code 2: EAN/UPC, 13 digits Code 3: None Code 4: CODE39, 8 digits When the unit successfully reads all 3 types of codes: Header

ABCDE12345

, 4901234567894 ,

KEYENCE1

Delimiter

When the unit fails to read Code 1 (CODE39, 10 digits) Header

ERROR

, 4901234567894 ,

KEYENCE1

Delimiter

When the unit fails to read Code 1 (CODE39, 10 digits) and Code 4 (CODE39, 8 digits)

3

Header

•

ERROR

, 4901234567894 ,

ERROR

Delimiter

When the same type of data having the same digits is specified to all Codes 1 to 4, the unit sends the data in the reading order.

Example Suppose that the following codes are specified: Code 1: CODE39, 7 digits Code 2: CODE39, 7 digits Code 3: CODE39, 7 digits Code 4: CODE39, 7 digits Header

ABCD123

,

XYZ3333

,

1234567

,

KEYENCE

,

Delimiter

Note: The unit cannot read the bar code having the same content twice while trigger input turns on once.

36

Page 50

Chapter 3

Label Orientation Mode As shown below, this mode allows the unit to read bar codes only in the specified orientation when bar code labels are moving both in the forward and reverse orientations. Forward Reverse orientation orientation 4 9000000

*

BL-700 TEST

TIMING

OK/NG

LASER ON

4 9000000

STB

3.3

Functions for Reading Operation

Normally, the unit can read bar codes regardless of the orientation. <Specified orientation>

3

<Non-specified orientation>

Trigger input Bar code Laser beams Communication time OK/NG output

OK/NG

NG

•

An reading error is issued when the unit reads a bar code label running in the orientation which is not specified.

•

The above chart applies to the single label read mode. You can also use this mode together with the desired multi-label read mode. However, in any case, the unit reads bar codes running in the specified orientation only.

•

You can specify the orientation individually for Codes 1 to 4, such as specifying “forward orientation” for Code 1, and “reverse orientation” for Code 2.

37

Page 51

Chapter 3

3.4

Functions for Reading Operation

Test Mode Test mode can be used for the bar code reading test. Because trigger input is not required, this mode allows you to perform a reading test easily. You can select one of the following 3 methods to enter the test mode.

3.4.1 Reading rate check mode The unit scans a bar code100 times and analyzes how many times it can decode the scanned data (reading rate). This mode is useful in the following cases: • •

When adjusting the mounting distance and angle When verifying the reading stability of the bar code to be used

This mode is enabled when the bar code label stays in the given position.

3

■ Operation Follow the instructions below: 1. Hold down the TEST switch for 3 seconds. (Release the switch when one STABILITY LED illuminates.) 2. The BL-700 then enters the mode in which the laser emission is always ON. Attempt to use the BL-700 to read bar codes. Reading distance Panel surface

10°

* Reading distance = 230 mm (BL-700/701) 380 mm (BL-740/741) 500 mm (BL-780/781)

3. Depending on the reading rate, the BL-700 displays the STABILITY LEDs as listed. By checking the display, adjust the reading distance and angle so that the reading rate reaches the highest level.

38

Reading rate

STABILITY LED

OK/NG LED

81 to 100 %

5 LEDs ON

Green

61 to 80 %

4 LEDs ON

Green

41 to 60 %

3 LEDs ON

Green

21 to 40 %

2 LEDs ON

Green

1 to 20 %

1 LED ON

Green

0%

–

Red

Page 52

Chapter 3

Functions for Reading Operation

4. In the test mode, the unit outputs the serial communication data in the following format every 100 scans. By connecting the BL-700 to a PC and using a BL setup software terminal, the following data can be displayed on the PC screen. ➮ See P.79 for details of operation. Delimiter Readout data

:

m * m = 0 to 100 (zero-suppressed)

*

ON/NG LED turns ON but OK/NG output does not turn ON.

5. Press the TEST switch again to exit the test mode. Tips

Gently pressing the TEST switch once (for less than 3 seconds) will cause the BL-700 to read a bar code once. (It also performs serial output and OK/NG output.)

3 3.4.2 Tact check mode In this test mode, the unit counts how many scans can be decoded (the decode count) while reading one bar code. This mode is useful when testing which line speed can be expected when actually implementing the BL-700 system on the line. This is enabled when the bar code label is moving. ■ Operation Follow the instructions below. 1. Hold down the TEST switch for 5 seconds. (Release the switch when two STABILITY LEDs illuminate.) 2. The BL-700 then enters the mode in which the laser emission is always ON. Attempt to use the BL-700 to read bar codes moving on the line. Reading distance Panel surface

10°

* Reading distance = 230 mm (BL-700/701) 380 mm (BL-740/741) 500 mm (BL-780/781)

3. Depending on the decode count, the BL-700 displays the STABILITY LEDs as listed below 0.2 seconds after the last bar code has passed the laser emission range. By checking the display, you can recognize how much stability the BL700 ensures during readout. To display the readout count, follow the procedure in 4 to display the data on the PC screen.

39

Page 53

Chapter 3

Functions for Reading Operation Reading rate

STABILITY LED

OK/NG LED

100 or more

5 LEDs ON

50 to 99

4 LEDs ON

Green (The readout count equals or exceeds the matching decode count.)

10 to 49

3 LEDs ON

5 to 9

2 LEDs ON

1 to 4

1 LED ON

0

–

Red (The readout count is below the matching decode count.) Red

The BL-700 continues to read the data while the laser beams scan the bar codes. Thus, the STABILITY LEDs are not ON. When the bar code reading stops for 0.2 seconds, the BL-700 stops scanning and turns ON the STABILITY LEDs. 4. In the serial communication mode, the BL-700 outputs the data in the following format. By connecting the unit to a PC and using the BL setup software terminal, the following data can be displayed on the PC screen.

3

➮ See P.77 for details of operation. Delimiter Readout data

:

m

* m = 1 to 9999 (zero-suppressed)

*

ON/NG LED turns ON but OK/NG output does not turn ON.

*

A value greater than 9999 cannot be added.

5. When reading the same bar codes continuously within 0.2 seconds, the BL-700 cannot separate the data and continues scanning to add the readout count. When reading different bar codes within 0.2 seconds, continuous scanning is enabled. 6. Press the TEST switch again to exit the test mode. Note 1: When the unit is running in test mode, the laser beam remains on, which can shorten the laser’s service life. Select the test mode only when you need to perform a test read. Avoid long emission times. Note 2: When using the “additional information” (➮ see P.46 to 47) in the test mode, the selected data is added in the same manner as in the normal operation mode. However, only when selecting the reading rate check mode, the decode count and scan count are not added to the analyzed results. Tips

40

To start the test mode, the following alternative method is available in addition to the method of using the TEST switch. •

Start the test mode using the serial commands (➮ see P.89) Send the test mode start command (TEST1, TEST2) to start the test command. By entering TEST1 or TEST2 and pressing [RETURN] from the provided setup software terminal, the test mode is started.

•

Start the test mode by turning the trigger input ON (➮ see P.58) Turning the timing input ON enables the setting to start the test mode. When this is set, the trigger input cannot function normally. Also, startup using the serial command is disabled. Use the setup software to perform the settings.

•

Start the test mode by turning power ON (➮ see P.58) Setting is available to start the test mode immediately at power-ON. Use the setup software to perform the settings.