Page 34

Chapter 2

Connection and Installation

2.3.6 Connecting the N-42 to RS-422A RS-422 terminal block assignment RS-422 SG SD+ SD– RD+ RD–

Code

Description

Signal direction

SG

Ground, SD+

Sends data to + terminal.

Output

SD-

Sends data to - terminal.

Output

RD+

Receives data from + terminal.

Input

RD-

Receives data from - terminal.

Input

2

Connecting external equipment ■ Connecting N-42 to external unit Use the same wiring when connecting the N-42 to the N-42. External unit (N-42)

Twisted pair cable

N-42

SG

SG

RD +

SD +

RD –

SD –

SD +

RD +

SD –

RD –

•

Turn ON the terminators (BL-U1/external unit terminal resistance: 100 Ω).

•

The cable can be extended to within 1.2 km.

➮ See P. viii.

■ Connecting KV-L2* Connecting the unit to RS-422A port 2 Link unit

Twisted pair cable

BL-U1*

SG

SG

RDB

SD+

RDA

SD–

SDB

RD+

SDA

RD–

■ Connecting the MELSEC-A series Connecting with AJ71C24, AJ71C24-S■, AJ71UC24, A0J2-C214-S1, A1SJ71(U)C24-R4 Link unit

Twisted pair cable

BL-U1*

SG

SG

RDA

SD+

RDB

SD–

SDA

RD+

SDB

RD–

21

Page 35

Chapter 2

Connection and Installation ■ Connecting SYSMAC-C series Connecting with C200H-LK202 (-V1), C500-LK201-V1, C500-LK203, C120-LK202-V1

SG

3

SG

Communication board SG 9

RDB

1

SD+

RDB

8

RDA

6

SD–

RDA

6

SD–

SDB

5

RD+

SDB

2

RD+

SDA

9

RD–

SDA

1

RD–

FG

7

Link unit

2

Connecting with C200HW-COM03/ COM06

Twisted pair cable

N-48

■ Connecting SYSMAC-CV series Connecting with CV-500-LK201, CV500, CV1000, CVM1 PLC

Twisted pair cable

9

SG

RDB

8

SD+

RDA

6

SD–

SDB

2

RD+

SDA

1

RD–

RS

4

CS

5

Note: BL-U1 and KV-L2 are not available in Europe.

22

N-42

SG

D-sub 9-pin (male) M2.6 screw

N-48 SG SD+

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (male) M2.6 screw

Twisted pair cable

Page 36

Chapter 2

2.4

Connection and Installation

Installation

2.4.1 Operating environment precautions Ambient environments This unit is a precision instrument and you must take care in choosing the operating environment. Do not install the unit in place as shown below: •

The unit is exposed to direct sunlight, or the ambient temperature may fall below 0°C (32°F) or exceed 40°C (104°F) (Power supply: 0 to 50°C (32 to 122°F));

•

The relative humidity may exceed the range of 35 to 85%, or condensation may occur due to rapid temperature changes;

•

Corrosive gas or inflammable gas is present, or a high level of dust, salt, iron particles or soot is present;

•

The unit is subject to vibration or impact;

•

Water, oil or chemicals may splash the unit;

•

A strong magnetic field or electric field is generated.

•

The ambient illumination intensity exceeds the range defined in the specification in P.120.

In-panel installation To mount the power supply unit BL-U1, BL-U2 or N-42, carefully observe the following instructions. •

Provide enough ventilation space.

•

If the ambient temperature may fall below 0°C (32°F) or exceed 50°C (122°F), provide a fan or air conditioner.

•

Do not mount this unit in a panel where a high voltage device is installed.

•

Place this unit as far away from power lines as possible.

Note: The BL-700 conforms to the protective structure defined in IP-65 (excluding the power supply unit connected). Although installation environments subject to dust and water will not affect the BL-700, adhesion of dust or water drops to the transmitter/receiver may disable readout of bar codes.

Hints on correct use • Trigger (TIM) input Set the trigger input to be long enough to allow the laser beam to cover the entire bar code. If the trigger input needs to be on for only a short period of time, select one-shot mode. • Influence from mirror surface If a mirror surface (metallic surface) is near the bar code and the laser beam reflects off the mirror, the BL-700 may cause a read error. Protect the unit from the influence of a mirror surface by covering the surface or changing the bar code label position.

23

2

Page 37

Chapter 2

Connection and Installation • Bar code pitch Do not place several bar codes in the field of the laser beam, unless you are in multi-label read mode (Multi 3). LASER ON STB OK/NG TIMING

TEST

BL-700

2

If you use multi-label read mode (multi 3), the BL-700 can simultaneously read 2 to 4 bar codes in the field of the laser beam. • Influence from photoelectric sensor When using a photoelectric sensor to control trigger, block the sensor beam so it does not enter the BL-700 optical pickup. The beam from the photoelectric sensor can interfere with the BL-700, deteriorating reading performance. If this case, reposition the photoelectric sensor. Object Bar code

LASER ON STB OK/NG TIMING

TEST

BL-700

Light source

Optical pickup

• Interference between the BL-700 units When two BL-700 units are placed adjacent to each other with only a small separation, the mutual laser beams result in interference and will cause a readout error. To avoid interference, place the units as far apart as possible.

• When a bar code is stained or partially missing Use a raster scan reader (BL-701/741/781) when a bar code is stained or partially missing. This raster scan readers scan several portions of the bar code. Normal portions of the bar code, even with stained or missing portions, can be read by the BL-700.

24

Page 38

Chapter 2

Connection and Installation

2.4.2 Installing the BL-700 series Installation method Use the mounting holes on the side panel to install the unit. ■ Installation with no mounting bracket

2

M3 nuts LASE R ON STB OK/NG

M3 screws

TIMING

TEST

BL-700

•

Select screws of the proper length by checking the thickness of the plate used for mounting. (The screws provided are for use with the mounting bracket.)

•

For the mounting hole diameter, see P.127.

■ Using the supplied mounting brackets Vertical scanning M4 screws Washer (accessory) Insulating spacer (accessory)

M3 screws (accessory)

Horizontal scanning M4 screws Washer (accessory) Insulating spacer (accessory)

BL-70 0 TEST OK TIM /NG ING STB

LAS ER

ON

M3 screws (accessory)

• • •

Use the set screw to secure the mounting bracket to the unit. For the mounting hole diameter, see P.127. When the insulating spacer is mounted, it can reduce the influence of noise from the mounting bracket.

25

Page 39

Chapter 2

Connection and Installation

Mounting angle and mounting distance Reading distance Panel surface

10° * Reading distance = 230 mm (BL-700/701) 380 mm (BL-740/741) 500 mm (BL-780/781)

2 Set the angle and reading distance by referring to the read range characteristics and angle characteristics described on P.122 to P.124. The allowable reading distance and angle may vary depending on the narrow bar width of the bar code, the bar code size, and the readability of the bar code. Set these parameters after performing a test read of the required bar code using the unit. Note: Do not set the unit at an angle at which the laser beam is perpendicular to the surface of the bar code. The beam will be fully reflected into the reader, making correct reading impossible (➮ See P.124). Incorrect 10°

Tips

The reading check test mode allows you to set the optimal reading position. ➮ To use the test mode, see P. 38.

26

Page 40

Chapter 2

Connection and Installation

2.4.3 Installing the BL-U1* There are 2 methods for installing the BL-U1: ■ When installing the BL-U1 directly Pull out the 4 screw slots on the rear panel and screw them to the base. 4 - ø5 98

2 150

■ When installing the BL-U1 to the DIN rail 1. Hook the BL-U1 to the DIN rail groove from its top. Push the BL-U1 bottom against the DIN rail until you hear a click.

2. Check that the DIN rail mounting notch is shaped like notch A below. If not, push the BL-U1 further. A

B

3. To remove the BL-U1 from the DIN rail, pull out the notch until its shape turns from Fig. B to Fig. A. Then, disengage the BL-U1 from the DIN rail. 4. When you want to reinstall the BL-U1 to the DIN rail, return the notch from that of Fig. A to Fig. B.

Note: BL-U1 is not available in Europe.

2.4.4 Installing the BL-U2, N-42 Install the BL-U2 or N-42 using the mounting hole. 2 - ø4.5 mm

READER POWER SD

43.2 mm

RD

BL-U2

RS-232C

63.2 mm

* The BL-U2 is 21 mm thick and the N-42 is 26 mm thick.

27

Page 41

Chapter 2

2

28

Connection and Installation

Page 42

Chapter 3 Functions for Reading Operation 3.1

Read Operation ................................................................... 30

3.1.1 Scanning method ................................................................... 30 3.1.2 Data-send mode .................................................................... 32 3.2

Read Modes ......................................................................... 33

3.2.1 3.2.2 3.2.3 3.2.4

Single label read mode .......................................................... 33 Multi-label read mode 1 (Multi 1) ........................................... 33 Multi-label read mode 2 (Multi 2) ........................................... 34 Multi-label read mode 3 (Multi 3) ........................................... 35

3.3

Label Orientation Mode ...................................................... 37

3.4

Test Mode ............................................................................ 38

3.4.1 Reading rate check mode ...................................................... 38 3.4.2 Tact check mode ................................................................... 39 3.4.3 Online test mode .................................................................... 41 3.5

STABILITY LEDs ................................................................. 42

3.6

Preset Function (Compare with:) ...................................... 44

3.6.1 What is the preset function? .................................................. 44 3.6.2 Wildcard Symbols (“!” and “?”) .............................................. 45 3.7

Additional Information ....................................................... 46

3.8

Max. Code Length (Designated Digit ) Output Function .................................................................. 48

Page 43

Chapter 3

3.1

Functions for Reading Operation

Read Operation

3.1.1 Scanning method There are two methods for triggering the BL-700 to read bar codes; the “Level signal” method and the “One-shot signal” method. The example given for these two methods uses the “single label read mode” (➮ see P.33), which reads one bar code while trigger input turns on once, and uses the “after read” as the data-send mode (➮ see P.32). ■ Level signal trigger When the trigger input turns on, laser emission begins and the unit begins reading. The laser turns off after reaching the specified decode count. Then, the unit sends the readout data.

3 <Succeed to read> Trigger input

<Fail to read> *1

Bar code Laser beams

*2

Communication time

*3

OK/NG output

OK/NG *4

NG

*5

*1. Set trigger input so that it stays on long enough for the laser beam to cover the entire bar code. *2. After the trigger input exceeds the preset input time, the laser begins to emit. ➮ See note on the next page.

*3. The communication time can be obtained from the following expression: Data bits + (1: If parity is used) + Start/stop bit Baud rate

(Code length of data to be X sent + Header/number of characters in delimiter)

*4. The length of time that the OK/NG output is on can be changed to between 10 ms and 2.55 s. *5. The OK/NG output turns on 5 ms after the data has been read (or trigger input turns off in case of reading failure). Note: 5 seconds after the power switch turns on or an UNLOCK command (➮ see P.90) is sent, the unit will not start reading a bar code by turning on the trigger input.