Page 24
Chapter 2
Connection and Installation
■ Connecting OK/NG output The OK/NG output is used to differentiate between acceptable and unacceptable results based on the comparison with the preset data, and to indicate whether or not the BL-700 series successfully read bar codes. ➮ See P.44. The OK/NG output is an open-collector output. COM
OK
NG *Rated load: 30 V max. (100 mA) Load
2
Load
+
■ I/O circuit diagram • Input circuit diagram
2.4 kΩ
Internal circuit
TIM
Internal circuit
3.3 kΩ
• Output circuit diagram
OK/NG
COM
Load
+
2.2.5 Connecting RS-232C Pin assignment 13
1
25
Pin No. Symbol
14
D-sub 25-pin (female) DCE specification (defined as terminal) M2.6 screw (female)
Function
Signal direction
1
FG
Frame ground, 2
SD (TXD)
Sends RS-232C data
Output
3
RD (RXD)
Receives RS-232C data
Input
4
RS (RTS)
Ready to send RS-232C data (always ON)
Output
5
CS (CTS)
Request to send RS-232C data
Input
6
DR (DSR)
Connected to pin No. 20 inside.
Input
7
GND (SG)
Signal ground, 20
ER (DTR)
Connected to pin No. 6 inside.
Output
11
Page 25
Chapter 2
Connection and Installation
Wiring the RS-232C cable ■ Connecting a PC 25-pin serial port
9-pin serial port
PC FG
1 2
2
SD
RD
3
3
RD
CS DR
4
4
RS
5
5
CS
6
6
DR
ER 20 SG 7
20 ER 7 SG
D-sub 25-pin (male) M2.6 screw
BL-U1 1
FG
RD
2
2
SD
SD
3
3
RD
ER
4
4
RS
SG
5
5
CS
DR
6
6
DR
RS CS
7
7
SG
8
8
CD
1
20 ER
Connector case
FG
1
SD RS
2
PC
BL-U1
D-sub 25-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw
* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.
D-sub 25-pin (male) M2.6 screw
* KEYENCE option OP-22149 (1.5 m) and OP-25057 (conversion connector) can be used.
■ Connecting KV series/Handheld programmer port Use the optional cable manufactured by KEYENCE.
OP-96368 (2.5 m)
KV-10, 16, 24 KV-40, 80
OP-96369 BL-U1*
KV-300*
Note: KV-300 and BL-U1 are not available in Europe. ■ Connecting KV-L2* Port 1
Port 2
KV-L2
BL-U1*
FG
1
1
FG
1
FG
SD
2
2
SD
SD
3
2
SD
RD
3
3
RD
RD
5
3
RD
RS
4
4
RS
4
RS
CS
5
5
CS
5
CS
DR
6
6
DR
6
DR
ER 20 SG 7 D-sub 25-pin (male) M2.6 screw
20 ER 7 SG D-sub 25-pin (male) M2.6 screw
* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.
12
KZ-L2
SG
1
Terminal block
BL-U1*
20 ER 7 SG D-sub 25-pin (male) M2.6 screw
Page 26
Chapter 2 ■ Connecting MELSEC-A series Connection with AJ71C24, AL71C24-S■, A0J2-C214-S1, AJ71UC24 Link unit FG SD
1 2
BL-U1* 1 2
Connection and Installation
Connection with A1SJ71(U)C24-R2/PRF, A2CCPUC24, A2CCPUC24-PRF
Link unit
BL-U1*
FG
Connector case
–
1
FG
SD
RD
2
2
SD
3
3
RD
RD
3
3
RD
SD
RS
4
4
RS
ER
4
4
RS
CS
5
5
CS
SG
5
5
CS
DR
6
6
DR
DR
6
6
DR
7
7
SG
SG
7
7
SG
RS
CD
8
8
CS
8
8
20 ER
CD
1
20 ER
ER 20 D-sub 25-pin (male) M2.6 screw
D-sub 25-pin (male) M2.6 screw
■ SYSMAC-C series Connection with C-200H-LK201(-V1), C-500-LK203, C-500-LK201-V1, C120-LK201-V1
D-sub 9-pin (male) M2.6 screw
D-sub 25-pin (male) M2.6 screw
Connection with C-20H, C-28H, C-40H, C-60H PLC
BL-U1*
FG
1
1
FG
FG
1
1
FG
SD
2
2
SD
SD
2
2
SD
RD
3
3
RD
RD
3
3
RD
RS
4
4
RS
RS
4
4
RS
CS
5
5
CS
CS
5
5
CS
SG
7
7
SG
SG
7
7
SG
Link unit
D-sub 25-pin (male) M2.6 screw
BL-U1*
D-sub 25-pin (male) M2.6 screw
2
D-sub 9-pin (male) M2.6 screw
D-sub 25-pin (male) M2.6 screw
* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.
Note: KV-L2 and BL-U1 are not available in Europe.
Connection with C-200HS(CPU21/23/31/33), CQM1(CPU21/41/42/43/44), C-200HE(CPU42), C200HG(CPU43/63), C200HX(CPU44/64), C200HW-COM02/COM04/COM05/COM06 PLC
BL-U1*
FG
1
1
FG
SD
2
2
SD
RD
3
3
RD
RS
4
4
RS
CS
5
5
CS
SG
9
7
SG
D-sub 9-pin (male) M2.6 screw
D-sub 25-pin (male) M2.6 screw
13
Page 27
Chapter 2
Connection and Installation ■ SYSMAC-CV series Connection with CV500-LK201 (Port 1)
Link unit
2
Connection with CV500-LK201 (Port 2), CV500, CV1000, CVM1
BL-U1*
PLC
BL-U1*
FG
1
1
FG
FG
1
1
FG
SD
2
2
SD
SD
2
2
SD
RD
3
3
RD
RD
3
3
RD
RS
4
4
RS
RS
4
4
RS
CS
5
5
CS
CS
5
5
CS
SG
7
7
SG
SG
9
7
SG
D-sub 25-pin (male) M2.6 screw
D-sub 25-pin (male) M2.6 screw
D-sub 9-pin (male) M2.6 screw
D-sub 25-pin (male) M2.6 screw
* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.
Note: BL-U1 is not available in Europe.
2.2.6 Wiring the RS-422A Wire the RS-422A as indicated below. ■ Connecting a general RS-422A unit Use the same wiring when connecting the BL-U1 to the BL-U1*. External unit BL-U1*
Twisted pair cable
BL-U1*
SG
SG
RD + (RDA)
SDA
RD – (RDB)
SDB
SD + (SDA)
RDA
SD – (SDB)
RDB
•
Turn ON the terminators (BL-U1/external unit terminal resistance: 100 Ω).
•
The cable can be extended to within 1.2 km.
➮ See P.35.
■ Connecting KV-L2* Connecting the unit to RS-422A port 2 Link Unit
14
Twisted pair cable
BL-U1*
SG
SG
RDB
SDA
RDA
SDB
SDB
RDA
SDA
RDB
Page 28
Chapter 2
Connection and Installation
■ Connecting the MELSEC-A series Connecting with AJ71C24, AJ71C24-S■, AJ71UC24, A0J2-C214-S1, A1SJ71(U)C24-R4 Link unit
BL-U1*
Twisted pair cable
SG
SG
RDA
SDA
RDB
SDB
SDA
RDA
SDB
RDB
2
Note: BL-U1 and KV-L2 are not available in Europe. ■ Connecting SYSMAC-C series Connecting with C200H-LK202 (-V1), C500-LK201-V1, C500-LK203, C120-LK202-V1 Link unit
Twisted pair cable
BL-U1*
SG
3
SG
RDB
1
SDA
RDA
6
SDB
SDB
5
RDA
SDA
9
RDB
FG
7
Connecting with C200HW-COM03/ COM06
Communication board
Twisted pair cable
BL-U1*
SG
9
SG
RDB
8
SDA
RDA
6
SDB
SDB
2
RDA
SDA
1
RDB
D-sub 9-pin (male) M2.6 screw
D-sub 9-pin (male) M2.6 screw
■ Connecting SYSMAC-CV series Connecting with CV-500-LK201, CV500, CV1000, CVM1 PLC
Twisted pair cable
BL-U1*
SG
9
SG
RDB
8
SDA
RDA
6
SDB
SDB
2
RDA
SDA
1
RDB
RS
4
CS
5
D-sub 9-pin (male) M2.6 screw
Note: BL-U1 is not available in Europe.
15
Page 29
Chapter 2
2.3
Connection and Installation
Wiring the KEYENCE Power Supply Unit BL-U2/N-42 To use the BL-U2/N-42, connect as indicated below.
2.3.1 Connecting the power supply Connect BL-U2/N-42 to a 24 VDC power supply. BL-U2
N-42
24V DC IN
2
+
CAUTION
24V DC IN
N.C. N.C. N.C. +
–
–
24 VDC
24 VDC
+
+
Make sure that the power supply provides 24 VDC. If the power supply output is not 24 VDC, it can damage the unit. Note: If the power supply is UL rated, it must provide Class 2 output.
2.3.2 Connecting the BL-700 to BL-U2/N-42 Connect the BL-700 to the READER port of the BL-U2/N-42.
READER
POWER
SD
RD
■ READER port pin assignment 1
2
6
Pin No.
3
7
4
8
5
D-sub 9-pin (male) DCE specification (defined as terminal) #4-40 screw (female)
9
Symbol
Function
Signal direction
1
TIM
Trigger input
Output
2
RD (RXD)
Receives RS-232C data
Output
3
SD (TXD)
Sends RS-232C data
Input
4
OK
OK signal
Input
5
GND (SG)
Ground (Common ground for respective signal), 6
NG
NG signal
Input
7
RS (RTS)
Ready to send RS-232C data
Input
8
CS (CTS)
Request to send RS-232C data
Output
9
+5 V
5 V power supply output
Output
Note: Do not extend a power cable. A long power cable can cause a voltage drop, preventing the BL-700 from starting properly.
16
Page 30
Chapter 2
Connection and Installation
2.3.3 Terminals of I/O terminal block and connections
TIM COM OK OG COM
* Viewed from the left of the unit
Symbol
Description
Signal direction
TIM
Trigger input
Input
COM
Common terminal for trigger input
Input
OK
OK output
Output
NG
NG output
Output
COM
Common terminal for output
Output
2
■ Connecting trigger input The trigger input allows the BL-700 to start reading bar codes (turn on the laser beam). To turn ON the trigger input, supply 15 to 26 VDC between the trigger input terminals.
TIM COM OK
Internal circuit
TIM
+ +
+
COM
+ 15 to 26 VDC
OK NG COM
+
Load
Internal circuit
■ Connecting OK/NG output The OK/NG output indicates the result of the comparison with preset data, or indicates whether reading is successful or not.
Load
+
Load
* Rated load: 30 V max. (100 mA)
17
Page 31
Chapter 2
Connection and Installation
2.3.4 Terminal A solderless contact pin, as shown below, is available for connection.
2.0 mm max.
5 mm max.
6 mm min
2
2.3.5 Connecting RS-232C (BL-U2) Pin assignment
1
2
3
4
5
D-sub 9-pin (male) DTE specification (defined as terminal) #4-40 screw 6
7
8
9
Pin No.
Symbol
Description
Signal direction
2
RD (RXD)
Receive data
Input
3
SD (TXD)
Send data
Output
4
ER (DTR)
Connected to pin No.6 inside.
Output
5
SG
Signal ground, 6
DR (DSR)
Connected to pin No.4 inside.
Input
7
RS (RTS)
Request to send data (always ON)
Output
8
CS (CTS)
Enable to send data
Input
* One connector is provided.
Wiring the RS-232C cable ■ Connecting a PC 25-pin serial port
9-pin serial port PC
BL-U2
RD
2
2
RD
SD
SD
3
3
SD
7
RS
RS
7
7
RS
5
8
CS
CS
8
8
CS
6
4
ER
ER
4
4
ER
ER 20 SG 7
6
DR
6
6
DR
5
SG
DR SG
5
5
SG
PC
BL-U2
FG
1
SD
2
2
RD
RD
3
3
RS
4
CS DR
D-sub 25-pin (male) M2.6 screw
Connector case
D-sub 9-pin (female) #4-40 screw
* KEYENCE option OP-22149 (1.5 m) or OP-25057 (conversion connector) can be used.
18
Connector case
Connector case
D-sub 9-pin (female) #4-40 screw
D-sub 9-pin (female) #4-40 screw
* KEYENCE option cable OP-27937 (1.5 m) can be used.
Page 32
Chapter 2
Connection and Installation
■ Connecting KV series/Handheld programmer port Use the optional cable manufactured by KEYENCE.
READER POWER SD RD RS-232C
BL-U2
OP-96368 (2.5 m) OP-96369 OP-25057
KV-10, 16, 24 KV-40, 80
BL-U2
2 KV-300*
■ Connecting KV-L2* Port 1 KV-L2*
Port 2
BL-U2
KV-L2*
BL-U1*
FG
1
SD
2
2
RD
SD
3
2
RD
RD
3
3
SD
RD
5
3
SD
RS
4
7
RS
7
RS
CS
5
8
CS
8
CS
DR
6
4
ER
4
ER
ER 20 SG 7
6
DR
6
DR
5
SG
5
SG
D-sub 25-pin (male) M2.6 screw
Connector case
D-sub 9-pin (female) #4-40 screw
Connector case
SG
1
Terminal block
D-sub 9-pin (female) #4-40 screw
* KEYENCE option OP-22149 (1.5 m) or the OP-25057 (conversion connector) can be used.
Note: KV-300, KV-L2 and BL-U1 are not available in Europe. ■ Connecting MELSEC-A series Connection with AJ71C24, AL71C24-S■, A0J2-C214S1, AJ71UC24 Link unit
Connection with A1SJ71(U)C24-R2/PRF, A2CCPUC24, A2CCPUC24-PRF Link unit
BL-U2
BL-U2
FG
1
SD
2
2
RD
RD
2
2
RD
RD
3
3
SD
SD
3
3
SD
RS
4
7
RS
RS
7
7
RS
CS
5
8
CS
CS
8
8
CS
DR
6
4
ER
ER
4
4
ER
SG
7
5
SG
DR
6
6
DR
CD
8
6
DR
SG
5
5
SG
CD
1
Connector case
ER 20 D-sub 25-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw
Connector case
Connector case
D-sub 9-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw
19
Page 33
Chapter 2
Connection and Installation ■ SYSMAC-C series Connection with C-200H-LK201(-V1), C-500-LK203, C-500-LK201-V1, C120-LK201-V1 Link unit
2
Connection with C-20H, C-28H, C-40H, C-60H
BL-U2
PLC
BL-U2
Connector case
FG
1
2
RD
SD
2
2
RD
3
3
SD
RD
3
3
SD
4
7
RS
RS
4
7
RS
CS
5
8
CS
CS
5
8
CS
SG
7
5
SG
SG
7
5
SG
FG
1
SD
2
RD RS
D-sub 25-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw
D-sub 9-pin (male) M2.6 screw
Connector case
D-sub 9-pin (female) #4-40 screw
* KEYENCE option OP-22149 (1.5 m) or the OP-25057 (conversion connector) can be used.
■ SYSMAC-C series Connection with C-200HS(CPU21/23/31/33), CQM1(CPU21/41/42/43/44), C-200HE(CPU42), C200HG(CPU43/63), C200HX(CPU44/64), C200HW-COM02/COM04/COM05/COM06 PLC
BL-U2 Connector case
FG
1
SD
2
2
RD
RD
3
3
SD
RS
4
7
RS
CS
5
8
CS
SG
9
5
SG
D-sub 9-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw
■ SYSMAC-CV series Connection with CV500-LK201 (Port 1)
Link unit
PLC
BL-U2
BL-U2 Connector case
Connector case
FG
1
2
RD
SD
2
2
RD
3
3
SD
RD
3
3
SD
4
7
RS
RS
4
7
RS
CS
5
8
CS
CS
5
8
CS
SG
7
5
SG
SG
9
5
SG
FG
1
SD
2
RD RS
D-sub 25-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw
* KEYENCE option OP-22149 (1.5 m) or the OP-25057 (conversion connector) can be used.
20
Connection with CV500-LK201 (Port 2), CV500, CV1000, CVM1
D-sub 9-pin (male) M2.6 screw
D-sub 9-pin (female) #4-40 screw