Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 19

Laser Bar Code Reader BL-700 Series User's Manual: Chapter 1 Laser Safety Precautions, pages 14 to 23

Pages 14 to 23 of 161, from Laser Bar Code Reader BL-700 Series User's Manual

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence BL-700, Keyence BL-701 and Keyence BL-781

Page 14

Chapter 1 Laser Safety Precautions 1.1

Classification ........................................................................ 2

1.2

Warning Labels ..................................................................... 2

1.3

Label Location ...................................................................... 3

1.4

Safety Consideration ............................................................ 4

1.5

Safety Features Provided with the BL-700 Series ............. 4

Page 15

Chapter 1

1.1

Laser Safety Precautions

Classification Model

1 1.2

BL-700/701

BL-740/741

FDA

Class II

IEC 825-1 11.1993

Class 2

DIN EN 60825-1 07.1994

Klasse 2

Warning Labels 1) Warning labels ■ FDA BL-700/701 AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.

CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650nm MAXIMUM OUTPUT 1.4mW PULSED RADIATION 91 µm CLASS II LASER PRODUCT

BL-740/741 AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.

CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650nm MAXIMUM OUTPUT 1.8mW PULSED RADIATION 50 µm CLASS II LASER PRODUCT

BL-780/781 AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.

CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650nm MAXIMUM OUTPUT 2.0mW PULSED RADIATION 91 µm CLASS II LASER PRODUCT

■ IEC BL-700/701

BL-740/741

LASER RADIATION DO NOT STARE INTO BEAM

LASER RADIATION DO NOT STARE INTO BEAM

Maximum output Pulse duration Emitted wavelength

Maximum output Pulse duration Emitted wavelength

1.4mW 91 µs 650nm

1.8mW 91 µs 650nm

CLASS 2 LASER PRODUCT

CLASS 2 LASER PRODUCT in conformity to IEC825-1 11.1993 in conformity to IEC825-1 11.1993

BL-780/781 LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength

2.0mW 91 µs 650nm

CLASS 2 LASER PRODUCT in conformity to IEC825-1 11.1993

■ DIN BL-700/701

BL-740/741

LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN

LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN

Maximum Leistung Pulsdauer Wellenlänge

Maximum Leistung Pulsdauer Wellenlänge

1,4mW 91 µs 650nm

1,8mW 91 µs 650nm

LASER KLASSE 2

LASER KLASSE 2 nach entwarf DIN EN 60825-1 07. 1994 nach entwarf DIN EN 60825-1 07. 1994

BL-780/781 LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN Maximum Leistung Pulsdauer Wellenlänge

2,0mW 91 µs 650nm

LASER KLASSE 2 nach entwarf DIN EN 60825-1 07. 1994

2

BL-780/781

Page 16

Chapter 1 2) Protective housing label ■ FDA CAUTION

LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.

■ IEC

Laser Safety Precautions

■ DIN CAUTION

VORSICHT

Laser radiation when open. Do not stare into beam.

Laserstrahlung wenn Abdeckung geöffnet. Nicht in den strahl blicken.

1 Labels Location FDA Warning labels are attached to the sensor head as shown below. The IEC/DIN Warning labels are packaged with the BL-700 Series. Affix the Warning labels on the sensor head as shown below.

AM L M T CL SED OU OR L AS RA TP AS S I DI UT ER LA ATI 650 SE ON RP 1.4 nm RO DU 9 mW CT 1 µ m

AV OID EX P

C A UT IO N

OS LA UR S IS ER E TH EMIT RAD IS TE IAT AP D IO ER FR N TU OM LA RE . DO SER NO RA T S DIA TA TIO RE NSE M INT MA ICO O N X BE PU IMU DUC

AV OID EX

PO LA SU S RE IS ER TH EMIT RAD IS TE IAT AP D IO RE T FRO N UR M LA E. DO SER NO RA T S DIA TA TIO R N

SE EI M NT MA ICO O X N BE PU IMU DUC L M T AM CL SED OU OR AS RA TP LA S DI UT SER I L AT AS IO 65 0 ER N 1 nm PR OD .4mW UC 91 T µm

CA UT IO N

■ FDA

LASE R ON

STB

OK/NG TIMIN G

ION DIAT R RAEN. . LASEN OP AM ION WHENOT TO BE UT CA DO E IN AR ST

TEST

BL-70 0

■ IEC

L D O ASE NO R R

Ma T A x S D P u im u T A IA T ls m R I Em e du out E I N ON it ra pu T CL ted w tion t O BE A in ASS ave 1 .4 M co 2 len nfo L gt m rm AS h 9 W ity E 1 to R P 6 5 µ s IEC R 0 n 82 OD m 5-1 U 11 CT .19 93

L NIC ASE HT RS IN TR

Ma xim DE AH uP ls um N ST LUN We dau Lei RAH G l e er stun L B nlä g LIC ng KE nac L e 1,4 N A mW eh nt SE wa R 91 rf D KL IN AS 65 µs EN S 0n 608 E 2 m 2510 7. 1 994

LASE R ON

STB

OK/NG TIMIN G

ION

UT when CA diation re r ra not sta Lase . Do . openbeam into

TEST

BL-70 0

■ DIN L NIC ASE HT RS IN TR

Ma xim DE AH uP ls um N ST LUN W e d a u L e i R AH G lle er stun L B nl ä g LIC ng KE nac L e 1,4 N A mW eh nt SE wa R 91 rf D KL IN AS 65 µs EN S 0n 608 E 2 m 2510 7. 1 994

L NIC ASE H R

Ma T IN STR x D A Pu imu EN HL ls m S U We dau Lei TRAH NG l e er stun L B nlä g LIC n KE nac L ge 1,4 N h e AS ntw E m arf R K 91 W DIN LA µ EN SS 650 s 60 E 2 nm 82 5-1 07 .1 99 4

1.3

LASE R ON

STB

OK/NG TIMIN G

HT

IC RS nn. . VO hlung we et öffn cken rstra g ge hl bli Lase ckun n stra Abdet in de Nich

TEST

BL-70 0

3

Page 17

Chapter 1

1.4

Laser Safety Precautions

Safety Consideration CAUTION

Use of controls or adjustment, or the performance of procedures other than those specified herein, may result in hazardous radiation exposure. The laser beam is not harmful to the skin. There is, therefore, no danger in exposing arms or hands to the beam. The only possible health hazard is in exposing the eyes to the laser beam. Damage to the eyes can occur if the operator stares directly into the beam.

1

Follow the safety precautions below to ensure operator safety: • Operate the BL-700 Series only according to the procedures described in this instruction manual. Otherwise, injury may occur due to exposure to the laser beam.

1.5

•

Do not disassemble the sensor head. Laser emission from the BL-700 Series is not automatically stopped if the sensor head is disassembled. If you disassemble the sensor head for inspection or repair, you may be exposed to the laser beam. If the BL-700 Series malfunctions, contact KEYENCE immediately.

•

Do not look directly at the laser beam. Looking directly at the laser beam may result in serious eye injury.

•

Protective enclosure We recommend that you install a protective enclosure around the sensor head to prevent any person from getting near the sensor head during operation.

•

Protective goggles We recommend that you wear protective goggles when using the BL-700 Series.

•

Stop laser emissions before cleaning the laser emission port. Failure to stop the laser emission may expose eyes or skin to the laser beam.

•

Check the laser beam path. To prevent exposure to the laser beam due to specular or diffuse reflection, install a screen which offers the appropriate reflectance and temperature characteristics to interrupt the reflected laser beam. Do not install the BL-700 Series in such a way that the laser beam passes at eye height.

Safety Features Provided with the BL-700 Series The BL-700 Series is provided with the following safety features. Make sure these features function correctly before operating. • Laser emission caution LED (LASER ON LED) During laser emission, the LASER ON LED illuminates. The LED ON status can be checked through the laser protective glasses. • Laser forced OFF command Sending the laser forced OFF command (LOCK, see P.92) to the BL-700 can inhibit emission of laser beams. When working near the laser transmitter, be sure to use the laser forced OFF command to avoid looking into the laser beams. When this command is selected, the bottom STABILITY LED flashes.

4

Page 18

Chapter 2 Connection and Installation 2.1

BL-700 connections .............................................................. 6

2.1.1 2.1.2 2.1.3 2.1.4

Connector pin assignment ....................................................... 6 Power supply connections ....................................................... 6 Wiring I/O ................................................................................. 7 RS-232C connection ................................................................ 7

2.2

Connecting BL-U1 and wiring ............................................. 8

2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6

Connecting the power supply .................................................. 8 Connecting the BL-700 ............................................................ 8 Setting BL-U1 DIP switches ..................................................... 9 Terminals of I/O terminal block and wiring ............................. 10 Connecting RS-232C ............................................................. 11 Wiring the RS-422A ............................................................... 14

2.3

Wiring the KEYENCE power supply unit BL-U2/N-42 ...... 16

2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.3.6

Connecting the power supply ................................................ 16 Connecting the BL-700 to BL-U2/N-42 .................................. 16 Terminals of I/O terminal block and connections ................... 17 Terminal ................................................................................. 18 Connecting RS-232C (BL-U2) ............................................... 18 Connecting the N-42 to RS-422A .......................................... 21

2.4

Installation ........................................................................... 23

2.4.1 2.4.2 2.4.3 2.4.4

Operating environment precautions ....................................... 23 Installing the BL-700 Series ................................................... 25 Installing the BL-U1 ............................................................... 27 Installing the BL-U2, N-42 ...................................................... 27

Page 19

Chapter 2

2.1

Connection and Installation

BL-700 Connections This section describes connections when a KEYENCE power supply unit is not used.

2.1.1 Connector pin assignment The BL-700 connector has the following pin assignment. 1

2

3

4

5

D-sub 9-pin (female) DTE specification (defined as terminal) #4-40 screw (male)

2 6

7

8

9

Pin No.

Cable color Symbol

Description

Signal direction

Connector case

Shield

Frame ground, 1

Yellow

TIM

Trigger input

Input

2

Brown

RD (RXD)

Receives RS-232C data

Input

3

Purple

SD (TXD)

Sends RS-232C data

Output

4

White

OK

OK output

Output

5

Black

GND (SG)

Ground (common ground for respective signals), 6

Gray

NG

NG output

Output

7

Pink

RS (RTS)

Request to send RS-232C data Output (always ON)

8

Blue

CS (CTS)

Enable to send data through RS-232C

Input

9

Red

+5 V

+5 V DC power supply

Input

FG

2.1.2 Power supply connections BL-700 +5V GND

CAUTION

9 5

+

5 VDC

•

Be sure to match the polarities of the power supply when soldering the connections. Reversing the polarities will damage the unit.

•

Make sure that the power supply provides a stable 5 VDC ± 5%. If the power supply does not function in the above range, it can damage the unit.

•

Do not extend the power cable. A long power cable can cause a voltage drop, preventing the BL-700 from starting properly.

Note: If the power supply is UL rated, it must provide Class 2 output.

6

Page 20

Chapter 2

Connection and Installation

2.1.3 Wiring I/O ■ Trigger input The trigger input is used to signal the BL-700 to start reading (start laser emission). The trigger input is a non-voltage input (TTL input is also available with negative logic).

Internal circuit

BL-700

10 kΩ

4.7 kΩ

TIM 1

2

Contact or solid-state

5 5 VDC

GND

■ OK/NG output This output signals whether the readout data is the same as the preset data. When no preset data has been entered, the signal indicates bar code read status. It is an NPN open-collector output. ➮

See P. 44

Internal circuit

BL-700

10 kΩ

OK/NG 4/6

Load

5

+

GND

* Rated load: 24 VDC (30 mA) max.

2.1.4 RS-232C connection Wire the RS-232C as indicated below when connecting the BL-700 to a PC. ■ Connecting the computer with 25-pin BL-700 RD 2 SD 3 CS 8 RS 7 GND 5 +5V 9 D-sub 9-pin (male) # 4-40 screw

PC 2 SD 3 RD 4 RS 5 CS 7 SG 6 DR 20 ER D-sub 25-pin (male) M2.6 screw

7

Page 21

Chapter 2

2.2

Connection and Installation

Connecting BL-U1 and Wiring Note: This product does not comply with EC directives. To use the BL-U1 AC power supply, connect it as described below.

2.2.1 Connecting the power supply Plug the BL-U1 power cable into an outlet.

2 FG line

CAUTION Use a power supply with 100 to 240 VAC ± 10% (50/60 Hz).

2.2.2 Connecting the BL-700 Connect the BL-700 to the READER port of the BL-U1. The BL-U1 READER port pin assignment is as described below.

■ BL-U1 READER port pin assignment 1

2

3

4

5

D-sub 9-pin (male) DCE specification (defined as terminal) #4-40 screw (female) 6

Pin No.

7

8

9

Symbol

Function

Signal direction

1

TIM

Trigger input

Output

2

RD (RXD)

Receives RS-232C data.

Output

3

SD (TXD)

Sends RS-232C data.

Input

4

OK

OK

Input

5

GND (SG)

Ground (Common ground for respective signal), 6

NG

NG

Input

7

RS (RTS)

Ready to send RS-232C data.

Input

8

CS (CTS)

Request to send RS-232C data. Output (Control method can be selected with the DIP switches.) ➮ See p. 9.

9

+5 V

+5 V power supply

Output

Note: Do not extend a power cable. A long power cable can cause a voltage drop, preventing the BL-700 from starting properly. Note: This product does not comply with EC directives.

8

Page 22

Chapter 2

Connection and Installation

2.2.3 Setting BL-U1 DIP switches Change the DIP switch settings depending on the selected interface and trigger input method.

OFF

* The figure on the left shows the default settings. ON

1

2

3

4

5

6

DIP Switch No. Interface selection

1

2

3

RS-232C

ON OFF OFF

RS-422A

OFF ON OFF

RS-485 multidrop

OFF OFF ON

4

5

6

RS-422A terminator

OFF

OFF

(Termination resistance: 100 Ω)

ON

ON

RS-485 terminator

OFF

OFF

(Termination resistance: 100 Ω)

ON

ON

Selection of READER port CS control method

ON or OFF according to the RS-232C port CS signal status.

OFF

Normally ON

ON

9

2

Page 23

Chapter 2

Connection and Installation

2.2.4 Terminals of I/O terminal block and wiring TIM

Trigger input

2

+12V OUT– COM

OK

NG

SDA

Power supply OK/NG output for sensors (12 VDC, 300 mA)

SDB

SG

RDA

RDB

RS-422A/RS-485

Symbol

Description

Signal direction

TIM

Trigger input

Input Input

+12 V OUT- + terminal of power supply for sensor (12 VDC, 300 mA) Output – terminal of power supply for sensor (0 V)

Output

COM

Common terminal for OK/NG output, OK

OK output

Output

NG

NG output

Output

SDA

+ terminal for RS-422A data transmission/ RS-485 + terminal

Output, Input/Output

SDB

– terminal for RS-422A data transmission/ RS-485 - terminal

Output, Input/Output

SG

Signal ground, RDA

+ terminal for RS-422A data reception

Input

RDB

– terminal for RS-422A data reception

Input

*

Viewed from the left of the terminal block

• •

M3.0 screws are used for the terminal block. Use the following crimp terminals for connections. Round-shape

Fork-shape

6.0 mm or less

6.0 mm or less

■ Connecting trigger input The trigger input allows the BL-700 series to start reading bar codes (turn on the laser beam). The trigger input is turned ON when 8.5 to 30 VDC input is activated between the trigger input terminals. The BL-U1 power supply for the sensor can be used as the input power supply. TIM

+12V OUT–

Contact or solid-state

+ + 8.5 to 30 VDC

10