Page 61

Chapter 4

Setup Software

Note: When reading a standard distribution code (bar codes on carton boxes), fix “Code length” to 14 or 16 digits in the [[Code setup]] screen and enable “Inspect check-digit [Modulus10/Weight3]”. For “Codabar”

“Start/stop character” “Inspect check-digit” “Send check-digit”

“Type of check-digit” Click the [OK] button to return to the [[Code setup]] screen.

•

“Start/stop character” If “Lower-case” or “Upper-case” is set, the BL-600 Series adds an “a”, “b”, “c”, or “d” (lowercase or uppercase) to the read data and sends it to the PC.

•

“Inspect check-digit” If “Inspect check-digit” is set, the option “Send check-digit” is activated (displayed in black).

•

“Send check-digit” If “Send check-digit” is set, the BL-600 Series sends the read data with the check digit to the PC.

•

“Type of check-digit” Select the type of check digit to use.

4

For “UPC/EAN”

“No. of UPC-A output” “Add UPC-E system code 0” “Add UPC-E system code 0” is only displayed when reading the UPC-E data.

*

Click the [OK] button to return to the [[Code setup]] screen.

•

“No. of the UPC-A output” Specify whether to use a 13-digit or a 12-digit output when reading the UPC-A data.

•

“Add UPC-E system code 0” If “Add” is selected, the BL-600 Series adds a “0” to the beginning of the data and sends it to the PC.

The check digit setting is not provided on the screen, but the BL-600 Series internally calculates it using modulus 10/weight 3. (The data is sent.)

51

Page 62

Chapter 4

Setup Software For “(Industrial) 2of5”, “COOP 2of5”, and “CODE93”

Click the [OK] button to return to the [[Code setup]] screen.

There are no detail setting parameters for these bar codes. For “CODE128”

“EAN-128 support”

4

Click the [OK] button to return to the [[Code setup]] screen.

“EAN-128 support” Check “EAN-128 support” to enable the BL-600 Series to accept the data configuration of EAN-128 specified as the international standard distribution code. ➮ See page 166. *

The check digit setting is not provided on the screen, but the BL-600 Series internally calculates it using modulus 103. (The data is not sent.)

3. Set the items for [Options]. When the [Options] button is clicked for “Code 1” to “Code 4”, the “Max code length output setup” screen appears. Set each item.

“Max code length output”

“Specify label orientation” Click the [OK] button to return to the [[Code setup]] screen.

“Max code length output” ➮ See page 107. To output only the selected digit(s) from the read data, specify the direction in which to select (“Direction”), the digit at which to begin selection (“Starting”), and the number of digits to be selected (“Effective”). “Specify label orientation” ➮ See page 93. If “Specify label orientation” is set, the BL-600 Series only reads bar codes moving with the specified orientation. Bar codes moving with any other orientation are not read.

52

Page 63

Chapter 4

Setup Software

4.2.6 [[Utility]] screen 1. Set the following items.

“OK/NG output duration”

“Stability LED”

“Preset data” [Options] button ➮ See below.

“OK/NG output duration” Set the “OK/NG output duration” with a numerical value between 1 and 255 (10 ms to 2.55 s).

4

“Preset data” ➮ See page 101. Set the length, up to 32 characters, of the bar code data to be entered. * If CODE-C is set for CODE128, up to 64 characters can be set. “Stability LED” ➮ See page 99. If “Use stability LED” is set, the BL-600 Series displays the STABILITY LEDs, which indicate the reading reliability during normal reading operation. 2. Set the items for [Options]. When the [Options] button is clicked, the “Special function setting” screen appears. Set each item.

“Reverse bar code reading” “Quiet zone scale”

“Decode cancel count” “Test SW output” Click the [OK] button to return to the [[Utility]] screen.

“Reverse bar code reading” If “Enable” is checked, the BL-600 Series reads bar codes printed in reverse (white-on-black). “Decode cancel count” Do not change from the initial value. “Quiet zone scale” Set the minimum value of the quiet zone width to be read with the BL-600 Series. Specify the scale factor of the quiet zone with reference to the narrow bar width (the narrowest bar width in the bar code). Do not change the initial value unless the quiet zone of the target bar code is small.

53

Page 64

Chapter 4

Setup Software “Test SW output” If “Enable” is set, the BL-600 Series sends the read bar code data or the successful reading rate data to the PC while in test mode. If you do not want to send data while in test mode, remove the check from “Enable”. ➮ See pages 96 and 98. * This setting is effective for all reading operations using the TEST switch. Reference: “Quiet zone” is the margin required on the right and left of a bar code. Normally, it should be 10 or more times wider than the narrow bar width.

4.3

Sending/Receiving Settings This section describes how to send data to or receive data from the BL-600 Series.

4.3.1 Sending/receiving settings to/from the BL-600 Series Perform the following procedure to read the settings of the BL-600 Series or to send the updated settings to the BL-600 Series.

4

*

To send/receive settings to/from the BL-600 Series via the BL-V35, refer to the BL-V35 User’s Manual.

1. Connect the BL-600 Series, special power supply unit, and personal computer. ➮ See “Chapter 3, Connection and Wiring”.

2. Set the BL-600 Series to “setting data send/receive waiting status”. 1) Press the BL-600 TEST switch for 8 seconds.

LASER ON

T

E

S

T

OK/NG TIMING

TEST

O T IM K /N G IN G LA

SE

RO

N

BL-600

2) When the 1st, 3rd and 5th STABILITY LEDs from the top flash simultaneously, the communication protocol is temporarily set as indicated below. • • • • • •

Baud rate: 9600 bits/s Data length: 7 bits Parity: Even Stop bit length: 1 bit PLC link: Disabled Multi-drop link: Disabled

Reference: If you know the current communication parameter settings of the BL600, this step is not necessary. You can send data to the BL-600 by setting the communication parameters of the host computer using [[Com Port]] so that they conform to the current settings of the BL-600.

54

Page 65

Chapter 4

Setup Software

Note: If PLC link is enabled, you cannot send data to the BL-600 without performing this step because the handshaking protocol is set for PLC link only. 3. Check or change the communication parameter settings of the personal computer. 1) Click on [[Com port]].

2) Set each parameter as shown below. 3) Select an appropriate RS-232C port. 4) When the settings are complete, click the [OK] button.

Select an appropriate RS-232C port.

4

Baud rate: 9600 bits/s Data length: 7 bits Parity: Even Stop bit length: 1 bit

Click the [OK] button to return to the previous screen.

4. Sending/receive settings to/from the BL-600 Series via the N-400. 1) Click on [[Transfer]].

2) The “Send/Receive settings (BL)” screen appears. • To send the updated settings to the BL-600 Series Click the [Send settings] button. •

To read the settings of the BL-600 Series Click the [Read BL settings] button.

Click the [Cancel] button to return to the previous screen.

55

Page 66

Chapter 4

Setup Software 5. Sending/reading result The following messages appear to indicate whether the sending/receiving operation was successful or whether it failed. Sending succeeded

Sending failed

If the operation failed, check the following points: • Check that the BL-600 Series is in the “setting data send/receive waiting status” during which the 1st, 3rd, and 5th STABILITY LEDs from the top flash simultaneously. • Check that [[Com port]] is set as shown in (3). • Check that the special power supply is turned on. • Check that the RS-232C cable pin assignment of the BL-600 is the same as that of the host computer. ➮ See pages 21, 28 and 35. Reading succeeded

Reading failed

4 6. Canceling the “setting data send/receive waiting status”. Press the TEST switch once. The “setting data send/receive waiting status” is canceled.

T

E

S

T

Press the TEST switch once.

O T IM K /N G IN G

LA SE RO N

56

Page 67

Chapter 4

Setup Software

4.3.2 Sending/receiving settings to/from the BL-600 Series via the N-400 Note: It is only possible to send/receive settings with a BL-600 Series that has already established a multi-drop link with the N-400. 1. Set the N-400 to “setting data send/receive waiting status”. 1) Press the N-400 TEST switch for 5 seconds.

Press the TEST switch for 5 seconds.

2) Communication can begin when “SO (50)” is displayed. 2. Check or change the communication parameter settings of the personal computer. 1) Click on [[Com port]].

2) Set each parameter as shown below. 3) Select an appropriate RS-232C port. 4) When the settings are complete, click the [OK] button. Select an appropriate RS-232C port. Baud rate: 9600 bits/s Data length: 7 bits Parity: Even Stop bit length: 1 bit

Click the [OK] button to return to the previous screen.

3. Sending/receive settings to/from the BL-600 Series via the N-400. 1) Click on [[Transfer]].

57

4

Page 68

Chapter 4

Setup Software 2) The “Send/Receive settings (BL)” screen appears. • To send the updated settings to the BL-600 Series Select “Use N-400” and enter the ID number of the desired BL-600 Series. Then, click the [Send settings] button.

Click the [Cancel] button to return to the previous screen.

•

To read the settings of the BL-600 Series Select “Use N-400” and enter the ID number of the desired BL-600 Series. Then, click the [Read BL settings] button.

4 Note: If improper settings are sent to the BL-600 Series, communication with the N-400 is disabled. To avoid problems, read the settings of the BL-600 Series first, then change only the necessary items. 4. Sending/reading result The following messages appear to indicate whether the sending/receiving operation was successful or whether it failed. Sending succeeded

Sending failed

If the operation failed, check the following points: • Check that the N-400 displays “SO (50)”. • Check that the settings for the [[Com port]] are specified as described in step 2. • Check that the N-400 and special power supply unit are turned on. • Check that the multi-drop link between the N-400 and the BL-600 Series is properly established. Reading succeeded

Reading failed

5. Canceling the “communication waiting status”. Press the TEST switch of the N-400 once. The “communication waiting status” is canceled.

Press the TEST switch once.

58

Page 69

Chapter 4

4.4

Setup Software

Reading/Saving/Printing File This section describes how to read, save, or print settings of a file.

4.4.1 [[Files]] screen The [[Files]] screen allows the following operation/setting of files (setting data). [Open] button Reads a file containing the saved settings of the BL-600 Series. [Save] button Saves the updated settings of the BL-600 Series to a file.

“Model” Select the model of the bar code reader that will be used.

[Compare] button Compares the file currently being edited with a file that was previously saved.

[Version Info] button Displays the version of the software.

[Print] button Prints the setting.

4 [Defaults] button Resets the edited settings to the initial (factory) settings.

4.4.2 Reading a previously saved setting file 1. Click the [Open] button. The “Open Settings file” screen appears. 2. Select a file and click the [OK] button. The saved file is opened.

[OK] button

Click [Cancel] to return to the previous screen.

59

Page 70

Chapter 4

Setup Software

4.4.3 Saving updated settings in a file 1. Click the [Save] button. The “Save Settings file” screen appears. 2. Click in the file name entry field and enter a file name. Up to 8 characters can be used for a file name. 3. Click the [OK] button. •

If the entered file name is illegal, an error message appears and the file is not saved. In this case, click the [OK] button and repeat steps 1 to 3. ➮ See page 67.

4 [OK] button Click [Cancel] to return to the previous screen.

•

If the file is properly saved, the following message appears.

Click the [OK] button to return to the initial screen.

Reference: If a file saved with a name consisting of only alphanumerics (alphabets and numbers) is sent to the BL-600 Series, the file name is also sent. In this case, when you read the settings of the BL-600 Series the next time, you can also read the file name to check the name of the current file of the BL-600 Series. This is convenient for maintenance. If characters other than alphanumerics are included in a file name, the file name is not sent to the BL-600 Series because the BL-600 Series cannot recognize them.

60