The text of a manual · part 8 of 8
Laser Bar Code Reader BL-600 Series User's Manual, pages 71 to 80
Pages 71 to 80 of 80
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-600 and Keyence BL-601
Page 71
Chapter 4
Setup Software
4.4.4 Comparing the contents of the file currently being edited with a saved file 1. Click the [Compare] button. The “Compare Settings file” screen appears. 2. Select a saved file to be compared and click the [OK] button. The selected saved file is compared with the file currently being edited.
[OK] button Click [Cancel] to return to the previous screen. If the settings match
4
If the settings do not match
4.4.5 Printing contents of a setting file 1. Click the [Print] button. The “Print” screen appears. 2. Specify each item as required. 3. Click the [OK] button to start printing.
[OK] button Click [Cancel] to return to the previous screen.
61
Page 72
Chapter 4
Setup Software
4.4.6 Resetting the edited settings to the initial (factory) settings 1. Click the [Defaults] button. If you click this button without saving the file currently being edited, a warning message appears. 2. To continue the initialization, click the [OK] button.
[OK] button Click [Cancel] to return to the previous screen.
Note: The [Defaults] button operation is used to initialize the edited settings of the setup software. The settings on the BL-600 Series cannot be initialized.
4 4.5
Using Monitor This setup software provides the “Monitor” program to check if the BL-600 can send data properly. The “Monitor” program allows you to display the data read by the BL Series on the host computer’s monitor screen, and also to send a command from the host computer to the BL-600 or BL Series.
4.5.1 Receiving data and checking the result The bar code data read with the BL-600 Series can be received with a personal computer and checked on the screen. 1. Set the communication parameters of the personal computer according to those of the BL-600 Series. ➮ See pages 54 and 55. 2. Click on [[Monitor]]. The MONITOR screen will appear.
62
Page 73
Chapter 4
Setup Software
3. Receive the bar code data. • •
The bar code data read with the BL-600 Series is displayed on the “Received Data” field. You can also see the history of the previous data (up to 1000 lines) using the scroll bar on the right of the “Received Data” field.
Scroll bar
4. Stopping the bar code data display
4
1) Click the [Stop] button. The name of the button changes to [Start] and display of the received data is stopped. [Stop] button
Click [Quit] to return to the previous screen.
2) When the [Start] button is clicked, the name of the button changes to [Stop] and display of the received data is restarted.
4.5.2 Command transmission ➮ See pages 114 to 128. 1. Set the communication parameters of the personal computer according to those of the BL-600 Series. ➮ See pages 54 and 55. 2. Click on [[Monitor]]. The MONITOR screen will appear.
63
Page 74
Chapter 4
Setup Software 3. Enter the serial communication command in the “Send Command” field (➮ See pages 114 to 128.) and press the [ENTER] key on the keyboard. Now, commands can be sent from a personal computer to the BL-600 Series. *
Use only uppercase characters for the commands.
[Quit] button
•
Command transmission with the command buttons Clicking the command buttons on the right side of the screen allows the following commands to be sent to the BL-600 Series.
4
[TEST1] button: Activates the reading rate check mode. [TEST2] button: Activates the tact check mode. [QUIT] button: Quits the test mode. [LON] button: Starts reading. [LOFF] button: Quits reading.
Command buttons
4. Checking the history of sent commands Clicking of the “Send Command” field displays the history of the sent commands (up to 100 commands).
Click [Quit] to return to the previous screen.
64
Page 75
Chapter 4
Setup Software
4.5.3 Starting the test mode The test mode of the BL-600 Series can be started with a command button. 1. Set the communication parameters of the personal computer according to those of the BL-600 Series. ➮ See pages 54 and 55. 2. Click on [[Monitor]]. The MONITOR screen will appear.
4 3. Start the test mode by clicking the [TEST1] or [TEST2] button. Operation of the BL-600 Series [TEST1] button: Activates the reading rate check mode. [TEST2] button: Activates the tact check mode. *
You can also start the test mode by typing “TEST1” or “TEST2” (uppercase only) in the “Send Command” field and sending it.
4. When the [QUIT] button is clicked, test mode is finished. *
You can also end the test mode by typing “QUIT” in the “Send Command” field and sending it.
65
Page 76
Chapter 4
Setup Software
4.5.4 Changing the scanning width The scanning width of the BL-600 Series can be changed with a command button. ➮ See page 117.
Note: When the scanning width is changed, the laser beam may not be properly applied to the bar codes, resulting in poor readings. Change the scanning width only when it is necessary. Thoroughly check that the change did not affect the reading performance. 1. Set the communication parameters of the personal computer according to those of the BL-600 Series. ➮ See pages 54 and 55. 2. Click on [[Monitor]]. The MONITOR screen will appear.
4
3. Click the [TEST1] button. The BL-600 Series enters test mode and emits a laser beam.
[TEST1] button
Clicking the [QUIT] button quits the test mode.
4. Specify the starting angle of scanning. Send the following command. SDEG a [ENTER] [a: 0 to 400 (Unit: 0.1°)] ↑ [*Initial value = 0] Input from the keyboard *
Specify an appropriate angle by checking the field of the laser beam.
5. Specify the scanning angle. Send the following command. WDEG b [ENTER] [b: 400 to 600 (Unit: 0.1°)] ↑ [*Initial value = 600] Input from the keyboard *
66
Specify an appropriate angle by checking the field of the laser beam.
Page 77
Chapter 4
Setup Software
6. When the setting is complete, quit the test mode. Click the [QUIT] button. *
The changed scanning width is retained even after the BL-600 Series is turned off. 60° c d b a
Approx. 60°
Approx. 60°
4 Note 1: The scanning width cannot be specified to exceed the angle range between “c” and “d” (60°). Note 2: The angle specified in the steps above should be used as a guide. If a precise setting is required, adjust the position of each bar code reader separately after installation.
4.6
List of Error Messages Contents The entered data is incorrect. Re-enter the correct data. Error during communication with the BL-600 (for sending settings). ➮ See page 56. Error during communication with the BL-600 Errors during (for reading settings). ➮ See page 56. communication The model set in the setup software is not the “The specified model is same as the model that is connected. incorrect. [OK]” Errors during setup
Error message “Entered data is incorrect. [OK]” “Communication with BL-600 failed. [OK]” “Readout from BL-600 failed. [OK]”
➮ See page 42.
Errors file editing
“Accessing file during rejected. [OK]”
No floppy disk is inserted. The floppy disk is write-protected. The floppy disk is full.
“File not found. [OK]” “File name incorrect. [OK]”
The file name is incorrect. Enter a correct file name. ➮ See page 60.
67
Page 78
Chapter 4
4.7
Setup Software
Example of Printing from the Setup Software When “Print” is executed from the setup software, the following data is printed.
/ / / New setting data [Untitled] / / / < < Model = BL-600 > >
[x] Selected [_] ----------=> Changed
1) Main [Read mode] [Data-send] [Repeat-reading time] [Decoding match count] [Read error] [Add Decoding match count] [Add scan count] [Add code type] [Add label orientation] [Add symbology ID.] [Add PMI.]
4
[x] Single [_] Multi 1 [_] Multi 2 [x] After read [_] At trigger input [10] x 100 ms [2] times ERROR [4552524F52] [_] Enable [_] Enable [_] Enable [_] Enable [_] Enable [_] Enable
[_] Multi 3
2) Trigger setup [Signal type] [One shot input time] [Input time] [State] [Command for Trigger ON] [Command for Trigger OFF] [Test mode initiated with input ON] [Test mode initiated upon power-up] [Power-on trigger]
[x] Level [_] One shot [10] x 100 ms [x] 2 ms [_] 10 ms [x] Normally open [_] Normally close LON [4C4F4E] LOFF [4C4F4646] [x] OFF [_] Reading-rate check [_] Tact check [x] OFF [_] Reading-rate check [_] Tact check [_] Enable
3) Comm Settings–1 [Baud rate] [data bits] [Parity] [Stop bits] [RTS/CTS] [Multi-drop link(RS-485)] [ID number]
9600 bps. [x] 7 bits [_] 8 bits [x] Even [_] Odd [x] 1 bit [_] 2 bits [_] Use RTS/CTS handshaking [_] Enable No. [1]
[_] None
4) Comm Settings–2 [Use PLC] [Handshaking] [Header] [Delimiter] [Partition mark] [Intermediate delimiter] [Checksum] [Send delay time]
[_] Enable [x] None [_] PASS/RTRY [_] ACK/NAK [x] None [_] STX [_] ESC [_] Custom [x] CR [_] CR+LF [_] ETX [_] Custom : [3A] , [2C] [_] Enable [0] ms
5) Utility [Stability LED] [OK/NG output duration] [Preset data] = [no data] [Reverse bar code reading] [Quiet zone scale] [Decode cancel count] [Test SW output]
[_] Use stability LED [50] x 10 ms [_] Enable [7] Times [0] [x] Enable
(1/2)
68
Page 79
Chapter 4
[Code 1 setup
Bar code = CODE39
[Max code length] [Min code length] [Send start/stop character (*)] [Inspect check-digit [Modulus 43] [Send check-digit] -----Options setup-----[Max code length output] [Effective] [Starting] [Specify label orientation]
[Code 2 setup]
[x] Not used [_] Forward [32] [1] [x] Not used [_] Forward
[_] Reverse
[_] Reverse
[32] [3] [_] Do not send [x] Lower-case [_] Upper-case [_] Enable [x] Enable Modulus 16 [x] Not used [_] Forward [32] [1] [x] Not used [_] Forward
4
[_] Reverse
[_] Reverse
Bar code = UPC/EAN
[Read EAN 13(UPC-A)] [Read EAN 8] [Read UPC-E] [No. of UPC-A output] [Add UPC-E system code 0] -----Options setup----[Max code length output] [Effective] [Starting] [Specify label orientation]
[Code 4 setup]
[32] [3] [_] Enable [_] Enable [x] Enable
Bar code = Codabar
[Max code length] [Min code length] [Start/stop character] [Inspect check-digit] [Send check-digit] [Type of check-digit] -----Options setup-----[Max code length output] [Effective] [Starting] [Specify label orientation]
[Code 3 setup]
Setup Software
[x] Enable [x] Enable [x] Enable [x] 13 digits [_] 12 digits [x] Do not add [_] Add [x] Not used [_] Forward [32] [1] [x] Not used [_] Forward
[_] Reverse
[_] Reverse
Bar code = CODE128
[Max code length] [Min code length] [EAN-128 support] -----Options setup----[Max code length output] [Effective] [Starting] [Specify label orientation]
[32] [1] [_] Enable [x] Not used [_] Forward [32] [1] [x] Not used [_] Forward
[_] Reverse
[_] Reverse
Printed: 99/08/07 20:40:28
(2/2)
69
Page 80
Chapter 4
4
70
Setup Software