4.1.5 Basic operation This section describes the basic operation of the setup software. ■ Selecting items Place the arrow (mouse pointer) on the item to be changed, and click the mouse. ■ Boxes and buttons Example [[Main]] (Operation setting) 1
[[Comm Settings-1]] (Communication parameters 1)
5
3
4
6
4
2
Indication 1 2
3
4
5
6
Operation Click on the tab to select the setting options. Click the check box to select items. ...The item is selected. ...The item is not selected. * With Windows Ver. 3.1, the enabled function is indicated as . Click the radio button to select items. ...The item is selected. ...The item is not selected. Used to select one of several options. Click at the side of the box to display the pull-down menu. Click the desired item from the menu. Enter the desired values in the text box. Click in the box and enter a numerical value using the keyboard. * If the entered value exceeds the available range, an error message appears. ➮ See page 67. Enter characters in the text box. Click in the box and enter characters using the keyboard. The box labeled “HEX” accepts the entry of hexadecimal numbers (00 to 7F) from the keyboard. Use this box to enter control characters (“00” to “”21h” of the ASCII code table, such as [CR] and [STX]). * If the entered value exceeds the available range, an error message appears. ➮ See page 67.
41
Page 52
Chapter 4
4.2
Setup Software
Setup Procedure This section describes each of the setting options.
4.2.1 Model selection Select the model of the bar code reader on the [[Files]] screen. 1. Click “BL-600” for “Model”.
Model selection
2. Check to see if “BL-600” appears as the title of the dialog box.
4
“BL-600”
4.2.2 [[Main]] (Operation setting) screen 1. Set the following items.
“Read Mode”
“Decoding match count”
Details of “Read Mode”
“Read error”
“Additional information”
[Trigger setup] button ➮ See page 44.
“Read Mode” ➮ See pages 88 to 92. Select a “Read Mode”. Details of “Read Mode” • If “Single” is selected: The following box appears. Select the “Data-send” option. ➮ See page 88.
42
•
If “Multi 1” or “Multi 2” is selected: The following box appears. Specify a “Repeat-reading time” ➮ See page 89. within the range of 1 to 255 (100 ms to 25.5 s).
•
If “Multi 3” is selected: Nothing appears.
Page 53
Chapter 4
Setup Software
“Additional information” ➮ See pages 102 to 106. Select the items as required. * “Scan count” only appears when “Decoding count” is selected.
When “PMI” is selected:
Click the [Set] button to display the “PMI output setting” screen. Specify a value within the range of 0 to 100 for each item. ➮ See pages 104 to 106.
4
“Decoding match count” Enter a desired value within the range of 1 to 255 (times). Specifying a large number for “Decoding match count” increases the reliability of the reading, but decreases the reading speed. Specifying a small number for “Decoding match count” increases the reading speed, but decreases the reliability of the reading. Typically, the initial value “2” is used. “Read error” Specify the error code that the BL-600 Series will send to the personal computer if it fails to read a bar code. This code can be changed as desired using 8 or less characters. Typically, the initial setting of “ERROR” is used. If the text box is left empty, the BL-600 Series will not send a read error code.
Reference: “Decoding match count” The BL-600 Series judges that a bar code has been properly read when the number of scans for successful decoding (reading) of the bar code (Decoding count) reaches the value specified in “Decoding match count”.
43
Page 54
Chapter 4
Setup Software 2. Set the items for [Trigger setup]. When the [Trigger setup] button is clicked, the “Trigger setup” screen appears. Set the following items. “State”
“Signal type”
“Input time”
“Command for Trigger ON”
“Command for Trigger OFF”
Starting method and type of test mode “Power-on trigger”
Click the [OK] button to return to the [[Main]] screen.
“Signal type” ➮ See pages 86 and 87. Select a “Signal type”. • If “One shot” is selected: The “One shot input time” setting box appears. Specify a value for the input time within the range of 1 to 255 (100 ms to 25.5 s).
4
“State” Select whether to emit a laser beam when the trigger input is on (Normallyopen) or when the trigger input is off (Normally-closed). Starting method and type of test mode Select this option to start the test mode if the trigger input is on or if the BL600 Series is turned on. Normally, this option is not selected. * If “Test mode initiated with trigger input ON” is selected, the trigger input cannot function normally. “Power-on trigger” • If “Enable” is not selected: The BL-600 Series does not emit a laser beam for 5 seconds after it is turned on, even if the trigger input turns on. •
If “Enable” is selected: The BL-600 Series emits a laser beam immediately after being turned on if the trigger input turns on. Select this option to activate the laser beam continuously once the BL600 Series has been turned on.
“Command for Trigger ON”/“Command for Trigger OFF” ➮ See page 115. Set the characters for the command used to control the reading operation (Laser ON/OFF) with command communication. Any number of characters, up to 8, can be set. Normally, the initial setting (LON: Trigger ON, LOFF: Trigger OFF) should be used. “Input time” Specify the ON time of the trigger input to enable the signal. Specify “10 ms” to ignore chattering of the contact when a contact type output (relay, etc.) is used for the trigger input.
44
Page 55
Chapter 4
Setup Software
4.2.3 [[Comm Settings-1]] (Communication parameters 1) screen Set the following items.
“Baud rate”
“RTS/CTS”
“Multi-drop link (RS-485)”
“Stop bits”
“Data bits” “Parity”
“Baud rate” “Data bits”
4
“Stop bits” “Parity” Set these communication parameters according to the settings of the external devices that will be connected (PC, PLC, etc.). “Multi-drop link (RS-485)” ➮ See “Multi-drop controller N-400 User’s Manual”.
1. Select “Enable” to use multi-drop link. * If the multi-drop link is enabled, “RTS/CTS” is disabled. 2. The “ID number (1-31)” setup box appears. Specify the ID number as a value between 1 to 31. Be sure not to set the same number for different BL-600 units in the same multi-drop link.
“RTS/CTS” Cannot be selected.
“ID number (1-31)”
“RTS/CTS” ➮ See page 112. Select “RTS/CTS” to suspend read data transmission with the CTS signal of RS-232C.
45
Page 56
Chapter 4
Setup Software
4.2.4 [[Comm Settings-2]] (Communication parameters 2) screen PLC link setting The settings vary depending on whether or not the PLC link will be used. First, select whether or not to use the PLC link with “Use PLC”.
“Use PLC” • If the PLC link is not used: ➮ See page 46.
• If the PLC link is used: ➮ See page 48.
4
If the PLC link is not used 1. Set the following items.
“Handshaking” [Character] button ➮ See page 47.
“Header”
[Option] button ➮ See page 47.
“Delimiter”
“Checksum”
“Handshaking” ➮ See pages 111 and 112. Select the type of communication forms (communication protocol) to send the read bar code data from the BL-600 Series to the personal computer. “Checksum” ➮ See pages 167 and 168. You can add data to check for incorrect data translation, such as garbled characters in the serial communication. “Header” “Delimiter” ➮ See page 113. Select the transmission format to send the read bar code data. If “Custom” is selected, the following text boxes appear. Type the desired header and delimiter (up to 5 characters) in each box.
46
Page 57
Chapter 4
Setup Software
2. Set the items for [Character]. When the [Character] button is clicked, the following screen appears. Set each item.
“Partition mark” (1 character) “Intermediate delimiter” (5 chars max.)
Click the [Return] button to return to the [[Comm Settings-2]] screen.
“Partition mark (1 character)” Specify the partition mark to separate the bar code data read with the BL600 Series and additional information. ➮ See pages 102 to 106. Any one character can be used. Normally, the initial setting of (:) should be used. “Intermediate delimiter (5 chars max.)” Specify the intermediate delimiter to separate each bar code data read in “Multi-label read mode 2 “ (➮ See page 90.) or “Multi-label read mode 3”. ➮ See page 91.
Any characters, up to 5, can be used. Normally, the initial setting of (,) should be used. 3. Set the item for [Option]. When the [Option] button is clicked, the following screen appears. Specify the “Send delay time”.
“Send delay time”
Click the [Return] button to return to the [[Comm Settings-2]] screen.
“Send delay time” Specify the response time, within the range of 0 to 255 (ms), for the time between the instant the BL-600 Series receives a command from the PC and the instant the BL-600 Series sends back a response.
47
4
Page 58
Chapter 4
Setup Software
If the PLC link is used Set the following items. ➮ Refer to “Chapter 8, PLC Link” for details.
“Connected PLC”
[Character] button ➮ See step 2 on page 47.
“PLC trigger area” “DM head address” “Station No.” * “Station No.” is not displayed if “KEYENCE KV Series” is selected for “PLC setup”.
“File Register enable” * “File Register enable” is only displayed if “MELSEC-A Series” is selected for “PLC setup”.
“Connected PLC” Specify the model of the PLC to be connected.
4
“PLC trigger area” ➮ See page 137. Check “Enable” to send a trigger signal to the BL-600 Series using the PLC link. “Station No.” Specify a station number between 0 to 31. “DM head address” ➮ See page 135. Specify a value for the head address of DM within the range of 0000 to 9900. “File Register enable” 1. Select “File Register enable” to use the file register (➮ See page 131.) as a device. 2. If the file register is enabled, the following screen appears. Specify a value, within the range of 000 to 255, for the block number of the file register to be used.
48
Page 59
Chapter 4
Setup Software
4.2.5 [[Code setup]] (Bar code setting) screen 1. Set the type of bar codes, readout digits and other functions.
Type of bar code “Code length”
[Details] button ➮ See page 50. [Options] button ➮ See page 52.
Type of bar code Select the type of bar code to be used. * If four different types of bar codes are specified in “Code 1” to “Code 4”, the BL-600 Series can read 4 types of bar codes without changing settings. “Code length” Specify the maximum number of digits for the bar code in “Max=” and the minimum number of digits in “Min=”. •
For “CODE39” Specify a value, between 3 and 32, for the number of digits including the “*” (start/stop character) and a check digit.
•
For “ITF” Specify a value, between 2 and 32, for the number of digits including a check digit (even numbers only).
•
For “(Industrial) 2of5” and “COOP 2of5” Specify a value, between 1 and 32, for the number of digits including a check digit.
•
For “Codabar” Specify a value, between 3 and 32, for the number of digits including “a”, “b”, “c”, “d” (start/stop characters) and a check digit.
•
For “UPC/EAN” A setting for the number of digits is not required. Select whether or not to enable the reading of each of 13-digit EAN (UPC-A), 8-digit EAN, and UPC-E.
•
For “CODE93” Specify a value, between 1 and 32, for the number of digits without a start/stop code and a check digit.
•
For “CODE128” Specify the number of digits without a start/stop code, check digit, FUN1 to 4 (function codes), “SHIFT”, and “CODE-A/B/C”. The available range varies depending on the type of start code (CODE-A to C). • •
CODE-A/B: 1 to 31 digits CODE-C: 1 to 64 digits
49
4
Page 60
Chapter 4
Setup Software Note 1: For “ITF”, “(Industrial) 2of5”, and “COOP 2of5”, be sure to fix the number of digits according to the bar code actually used. Otherwise, some digits may be skipped (not read) without recognition. Example To fix the number of digits to “8” Specify “Max=” as “8” and “Min=” as “8”. Note 2: It is recommended to fix the number of digits for “Codabar”. Some digits may be skipped depending on the print condition or the position of the bar code reader. Note 3: When reading only one type of bar code, specify it in “Code 1” and leave the other boxes as “None”. This decreases the possibility of misreading. 2. Set the items for [Detail]. When the [Detail] button of “Code 1” through “Code 4” is clicked, the “Bar code detail setup” screen appears. Specify each item. The items vary depending on the specified type of bar code. For “CODE39”
4
“Send start/stop character (*)” “Inspect check-digit [Modulus 43]” “Send check-digit”
Click the [OK] button to return to the [[Code setup]] screen.
•
“Send start/stop character (*)” If “Send start/stop character (*)” is set, the BL-600 Series adds an “*” (asterisk) to the read data and sends it to the PC.
•
“Inspect check-digit [Modulus 43]” If “Inspect check-digit [Modulus 43]” is set, the option “Send check-digit” is activated (displayed in black).
•
“Send check-digit” If “Send check-digit” is set, the BL-600 Series sends the read data with the check digit to the PC.
For “ITF”
“Inspect check-digit [Modulus10/Weight3]” “Send check-digit” Click the [OK] button to return to the [[Code setup]] screen.
50
•
“Inspect check-digit [Modulus10/Weight3]” If “Inspect check-digit [Modulus10/Weight3]” is set, the option “Send check-digit” is activated (displayed in black).
•
“Send check-digit” If “Send check-digit” is set, the BL-600 Series sends the read data with the check digit to the PC.