The text of a manual · part 5 of 8
Laser Bar Code Reader BL-600 Series User's Manual, pages 41 to 50
Pages 41 to 50 of 80
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-600 and Keyence BL-601
Page 41
Chapter 3
Connection and Installation
3.2.4 Connecting the N-42 to RS-422A RS-422 terminal block assignment The terminals of the RS-422A terminal block of the N-42 are assigned as shown in the figure.
R
■ RS-422 terminal block assignment
S
D
R
D
R
E
A
D
E
RS-422
F
M R
O
E
F O
T
N
IN
A T O
R
P
O
W
E
R
SG SD+ SD– RD+ RD–
RS-422 terminal block
Code
Description
Signal direction
SG
Ground
SD+
Sends data to + terminal.
Output, SD-
Sends data to - terminal.
Output
RD+
Receives data from + terminal.
Input
RD-
Receives data from - terminal.
Input
N F
F
O O
T
E
R
M
IN
A T O
R
Note 1: The cable can be extended to within 1.2 km. Note 2: Turn ON the terminators (BL-U1/external unit terminal resistance: 100 Ω).
[ON]
Wiring the RS-422A Connect the N-42 to other devices with the following wiring. ■ Connecting a general RS-422A unit Use the same wiring when connecting the N-42 to the N-42. External unit (N-42)
Twisted pair cable
N-42
SG
SG
RD +
SD +
RD –
SD –
SD +
RD +
SD –
RD –
31
3
Page 42
Chapter 3
Connection and Installation ■ Connecting the MELSEC-A Series ■ Connecting SYSMAC-C Series Connecting with AJ71(U)C24(-S■), Connecting with C200H-LK202 (-V1), AJ71QC24-R4, C500-LK201-V1, A0J2-C214-S1, C500-LK203, A1SJ71(U)C24-R4 C120-LK202-V1 Link unit
Twisted pair cable
N-42
Link unit
Twisted pair cable
N-42
SG
SG
SG
3
SG
RDA
SD+
RDB
1
SD+
RDB
SD–
RDA
6
SD–
SDA
RD+
SDB
5
RD+
SDB
RD–
SDA
9
RD–
FG
7
D-sub 9-pin (male) M2.6 screw
3 ■ Connecting SYSMAC-C Series ■ Connecting SYSMAC-CV Series Connecting with C200HW-C0M03/CPM06 Connecting with CV-500-LK201, CV500, CV1000, CVM1 Communication board SG 9
Twisted pair cable
PLC
N-42
N-42
SG
9
SG
SD+
RDB
8
SD+
RDB
8
RDA
6
SD–
RDA
6
SD–
SDB
2
RD+
SDB
2
RD+
SDA
1
RD–
SDA
1
RD–
RS
4
CS
5
D-sub 9-pin (male) M2.6 screw
D-sub 9-pin (male) M2.6 screw
32
Twisted pair cable
SG
Page 43
Chapter 3
3.3
Connection and Installation
Wiring without the Special Power Supply Units This section describes the connection and wiring of the BL-600 Series and peripheral devices when a special power supply unit is not used.
3.3.1 Pin assignments of the BL-600 Series connector and the connecting power supply Pin assignment of the BL-600 Series power supply connector ■ Connector pin assignment 5
4
3
2
1
D-sub 9-pin (female) #4-40 screw (male) 9
8
7
LA
SE
OK
R ON
/N
TIM
G
IN
G
TE
ST
6
Connector
Pin No.
Cable color
Symbol
Signal direction
Description
Connector case 1
Shield
FG
Frame ground, Yellow
Trigger input
Input
2
Brown
Receives RS-232C data
Input
3
Purple
Sends RS-232C data
Output
4
White Black
6
Gray
7
Pink
OK output Ground (Common ground for respective signals) NG output Request to send RS-232C data (always ON)
Output
5
8
Blue
Enable to send data through RS232C
Input
9
Red
TIM RD (RXD) SD (TXD) OK GND (SG) NG RS (RTS) CS (CTS) +5 V
+5 V power supply
Input, Output Output
Power supply connections Connect the 5 V DC power supply to the power supply connector of the BL-600 Series. BL-600 +5V GND
CAUTION
9
+
5 V DC
5
•
Be sure to match the polarities of the power supply when soldering the connections. Reversing the polarities will damage the unit.
•
Make sure that the power supply provides a stable 5 V DC ± 5%. If the power supply does not function in the above range, it can damage the unit.
Note1: Do not extend the power cable. A long power cable can cause a voltage drop, preventing the BL-600 from starting properly. Note2: If the power supply is UL rated, it must provide Class 2 output.
33
3
Page 44
Chapter 3
Connection and Installation
3.3.2 I/O Wiring Trigger input The trigger input is used to signal the BL-600 to start reading (start laser emission). The trigger input is a non-voltage input (TTL input is also available with negative logic). Circuit diagram
Internal circuit
BL-600
3
10 kΩ
5 V DC
4.7 TIM kΩ 1
Contact or solid-state
5 GND
■ Connection to a photoelectric sensor manufactured by KEYENCE BL-600
Photoelectric sensor + Brown (Red)
TIM 1
Black (White)
5
Blue (Black) GND
OK/NG output The OK/NG output is used to display the comparison/verification result of the preset data. ➮ See page 101. When no preset data is registered, it can be used to display whether or not bar codes are being read correctly. The output form is NPN open-collector. Circuit diagram
Internal circuit
BL-600
10 kΩ
OK/NG 4/6 5 GND
Load + * Rated load: 24 V DC (30 mA) max.
■ Connection to a programmable logic controller (PLC) manufactured by KEYENCE PLC BL-600 OK/NG 0000
4/6 5
+ GND
34
C
Page 45
Chapter 3
Connection and Installation
3.3.3 RS-232C connection Wire the RS-232C as indicated below when connecting the BL-600 to a PC. Connecting the computer with 9-pin PC
BL-600 RD 2 SD 3
3 SD
RS 7
8 CS
CS 8
7 RS
GND 5
5 SG
+5V 9
4 ER 6 DR
D-sub 9-pin (male) # 4-40 screw
2 RD
+
D-sub 9-pin (female) # 4-40 screw
Connecting the computer with 25-pin BL-600 RD 2 SD 3 CS 8 RS 7 GND 5 +5V 9 D-sub 9-pin (male) # 4-40 screw
PC 2 SD 3 RD 4 RS 5 CS 7 SG 6 DR 20 ER D-sub 25-pin (male) M2.6 screw
3
35
Page 46
Chapter 3
3
36
Connection and Installation
Page 47
Chapter 4 Setup Software This chapter describes the usage of the setup software to set or perform reading tests of the BL-600 Series.
4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5
Installing and Operating the Setup Software .................... 38 Installation and operation procedures .................................... 38 Installing setup software ........................................................ 39 Installation/Start-up ................................................................ 39 Initial screen ........................................................................... 40 Basic operation ...................................................................... 41
4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.6
Setup Procedure .................................................................. 42 Model selection ...................................................................... 42 [[Main]] (Operation setting) screen ........................................ 42 [[Comm Settings-1]] (Communication parameters 1) screen .... 45 [[Comm Settings-2]] (Communication parameters 2) screen .... 46 [[Code setup]] (Bar code setting) screen ............................... 49 [[Utility]] screen ...................................................................... 53
4.3 Sending/Receiving Settings ............................................... 54 4.3.1 Sending/receiving settings to/from the BL-600 Series ........... 54 4.3.2 Sending/receiving settings to/from the BL-600 Series via the N-400 ......................................................................... 57 4.4 4.4.1 4.4.2 4.4.3 4.4.4
Reading/Saving/Printing File .............................................. 59 [[Files] screen ........................................................................ 59 Reading a previously saved setting file ................................. 59 Saving updated settings in a file ............................................ 60 Comparing the contents of the file currently being edited with a saved file ..................................................................... 61 4.4.5 Printing contents of a setting file ............................................ 61 4.4.6 Resetting the edited settings to the initial (factory) settings... 62 4.5 4.5.1 4.5.2 4.5.3 4.5.4
Using Monitor ....................................................................... 62 Receiving data and checking the result ................................. 62 Command transmission ......................................................... 63 Starting the test mode ............................................................ 65 Changing the scanning width ................................................. 66
4.6
List of Error Messages ........................................................ 67
4.7
Example of Printing from the Setup Software .................. 68
Page 48
Chapter 4
4.1
Setup Software
Installing and Operating the Setup Software This section describes the installation and operation procedures of the setup software.
4.1.1 Installation and operation procedures The following chart shows the installation and setup procedures of the setup software. * The shaded boxes indicate an operation of the setup software or a personal computer.
Check the operating environment.
➮ See page 39.
➞ Install the setup software.
➮ See page 39.
➞ Connect the BL-600 Series to a personal computer with the RS-232C cable.
4
➞ Start the setup software.
➮ For the applicable cable and wiring, see “3.1 Connecting BL-U1 and Wiring” on page 16 or “3.2 Connecting the BL-U2 or N-42 and Wiring” on page 25. ➮ See pages 39 to 40.
➞ Select “BL-600” for “Model”.
➮ See page 42.
➞ Specify each item.
➮ See pages 42 to 54.
➞ Press the TEST switch of the BL-600 Series for 8 seconds.
➮ See page 54.
➞ Send the updated settings to the BL-600 Series.
➮ See page 54.
➞
* The current settings of the BL-600 Series can be read from the PC. * If the multi-drop link is established with the N-400, the settings of the BL-600 Series can also be changed via the N-400. ➮ See pages 57 and 58.
Press the TEST switch of the BL-600 Series once.
➮ See page 56.
➞ Save or print the settings as required.
➮ See pages 60 and 61.
➞ Quit the setup software.
38
➮ See page 40.
Page 49
Chapter 4
Setup Software
4.1.2 Installing setup software Items PC OS Floppy disk drive Display Serial port
Requirements IBM PC/AT MS-Windows 3.1 MS-Windows 95 MS-Windows 98 3.5 inch floppy disk drive (1.44 MB compatible) Resolution 640 x 480 or higher A minimum of one RS-232C port is required.
4.1.3 Installation/Start-up 1. Insert the BL-600 setup software system disk into the floppy drive. 2. Perform the following procedure. •
•
Windows 3.1: Execute “Run...” in the icon menu of the program manager.
4
Windows 95/98: Select “Run” from the "Start" menu.
3. Run the “SETUP” file from the floppy disk drive. Type in as follows: A: \SETUP 4. The setup software installer starts. Follow the instructions of the installer program. Typically, clicking [Next (N)>] twice will complete the installation procedure. 5. Specify the directory to install the setup software into. The setup software is normally installed in the following directory. C: \KEYENCE\BLSET If this directory is correct, click on [Next (N)]. If you wish to change the directory, click on [Browse (R)..], and select the desired directory.
39
Page 50
Chapter 4
Setup Software 6. Completing the installation (1)
When the installation begins, the file copy process is displayed as a graph.
(2)
When the installation is complete, the following message appears.
7. Start the setup software. For Windows Ver. 3.1, double-click the “BL” icon in the “KEYENCE” group. For Windows 95/98, start the program from the Start Menu.
4.1.4 Initial screen This section describes the initial screen of the setup software.
4
Shows the name of the stored file currently being edited, or the status of the item currently being changed. Operating status
Indication
All settings have the initial values.
<<Default>>
The file is read from the PC memory.
<<File: (File name)>>
The file is read from the BL-600 series. <<BL:>> One or more items have changed from the initial settings or from the status they (changed) were at when the file was read from memory.
Shows the model of the bar code reader that is currently selected. Shows the setting options. Main (Operation setting:) ➮ See pages 42 to 44.
Comm Settings-1 (Communication parameters 1:) ➮ See page 45.
Comm Settings-2 (Communication parameters 2:) ➮ See page 46 to 48.
Code setup (Bar code setting:) ➮ See pages 49 to 52.
Utilities: ➮ See pages 53 to 54.
Files: ➮ See pages 59 to 62.
40
Com port:
Monitor:
➮ See pages 55 and 57.
➮ See pages 62 to 66.
Transfer:
Exit: Click this button to quit the setup software.
➮ See pages 55 to 57.