Page 31

Chapter 3

Connection and Installation

Wiring the RS-232C cable Connect the BL-U1 to a personal computer or other devices with the following wiring. ■ Connecting a PC 9-pin serial port

25-pin serial port

PC

BL-U1

Connector case

PC

BL-U1

1

FG

FG

1

1

FG

RD

2

2

SD

SD

2

2

SD

SD

3

3

RD

RD

3

3

RD

ER

4

4

RS

RS

4

4

RS

SG

5

5

CS

CS

5

5

CS

DR

6

6

DR

DR

6

6

DR

RS CS

7

7

SG

8

8

ER 20 SG 7

CD

1

20 ER

D-sub 9-pin (female) #4-40 screw

D-sub 25-pin (male) M2.6 screw

* KEYENCE option OP-22149 (1.5 m) and OP-25057 (conversion connector) can be used.

D-sub 25-pin (male) M2.6 screw

20 ER 7 SG D-sub 25-pin (male) M2.6 screw

* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.

■ Connecting NEW KV Series/Communication port KV-10/16/24/40 Communication port

BL-U1

SD

3

2

SD

RD

5

3

RD

4

RS

SG

4 RJ11

5

CS

6

DR

20

ER

7

SG

D-sub 25-pin (male) M2.6 screw

* KEYENCE option OP-96368 (2.5 m) and OP-96369 (conversion connector) can be used.

■ Connecting KV-L2* Port 1

Port 2

KV-L2

BL-U1*

FG

1

1

FG

1

FG

SD

2

2

SD

SD

3

2

SD

RD

3

3

RD

RD

5

3

RD

RS

4

4

RS

4

RS

CS

5

5

CS

5

CS

DR

6

6

DR

6

DR

ER 20 SG 7 D-sub 25-pin (male) M2.6 screw

20 ER 7 SG D-sub 25-pin (male) M2.6 screw

KV-L2

SG

1

Terminal block

BL-U1*

20 ER 7 SG D-sub 25-pin (male) M2.6 screw

* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.

21

3

Page 32

Chapter 3

Connection and Installation ■ Connecting MELSEC-A Series Connection with AJ71(U)C24(-S■), AJ71QC24-R2, A0J2-C214-S1 Link unit

Link unit

1

1

FG

Connector case

–

1

FG

SD

2

2

SD

RD

2

2

SD

RD

3

3

RD

SD

3

3

RD

RS

4

4

RS

ER

4

4

RS

CS

5

5

CS

SG

5

5

CS

DR

6

6

DR

DR

6

6

DR

SG

7

7

SG

RS

7

7

SG

CD

8

8

CS

8

8

20 ER

CD

1

20 ER

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

■ SYSMAC-C Series Connection with C200H-LK201(-V1), C500-LK203, C500-LK201-V1, C120-LK201-V1 Link unit FG SD

1 2

D-sub 9-pin (male) M2.6 screw

Connection with C20H, C28H, C40H PLC

BL-U1*

FG

FG

1

1

FG

SD

SD

2

2

SD

3

3

RD

BL-U1* 1 2

D-sub 25-pin (male) M2.6 screw

RD

3

3

RD

RD

RS

4

4

RS

RS

4

4

RS

CS

5

5

CS

CS

5

5

CS

SG

SG

7

7

SG

SG

7

D-sub 25-pin (male) M2.6 screw

7

D-sub 25-pin (male) M2.6 screw

D-sub 9-pin (male) M2.6 screw

* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.

Connection with C200HS-CPU21/23/31/33, CQM1-CPU21/41/42/43/44, C200HE-CPU32/42, C200HG-CPU33/43/53/63, C200HW-COM02/COM04/COM05/COM06 C200HX-CPU34/44/54/64, C200HX-CPU65-Z/85-Z PLC

BL-U1*

FG

1

1

FG

SD

2

2

SD

RD

3

3

RD

RS

4

4

RS

CS

5

5

CS

SG

9

7

SG

D-sub 9-pin (male) M2.6 screw

22

BL-U1*

FG

ER 20

3

BL-U1*

Connection with A1SJ71(U)C24-R2/PRF, A2CCPUC24(-PRF)

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

Page 33

Chapter 3 ■ SYSMAC-CV Series Connection with CV500-LK201(Port 1)

Link unit FG SD

Connection with CV500-LK201 (Port 2), CV500, CV1000, CVM1 PLC

BL-U1*

FG

FG

1

1

FG

SD

SD

2

2

SD

3

3

RD

BL-U1*

1

1

2

2

Connection and Installation

RD

3

3

RD

RD

RS

4

4

RS

RS

4

4

RS

CS

5

5

CS

CS

5

5

CS

SG

7

7

SG

SG

9

7

SG

D-sub 25-pin (male) M2.6 screw

D-sub 9-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

* KEYENCE option OP-22149 (1.5 m) or commercially available cross cable can be used.

3

3.1.5 Wiring the RS-422A Note 1: The cable can be extended to within 1.2 km. Note 2: Turn ON the terminators (BL-U1/external unit terminal resistance: 100 Ω). ➮ See page 17.

Connect the BL-U1 to other devices with the following wiring. ■ Connecting a general RS-422A unit Use the same wiring when connecting the BL-U1 to the BL-U1*. External unit BL-U1*

Twisted pair cable

BL-U1*

SG

SG

RD + (RDA)

SDA

RD – (RDB)

SDB

SD + (SDA)

RDA

SD – (SDB)

RDB

■ Connecting the MELSEC-A Series Connecting with AJ71(U)C24(-S■), AJ71QC24-R4, A0J2-C214-S1, A1SJ71(U)C24-R4 Link unit

Twisted pair cable

BL-U1*

SG

SG

RDA

SDA

RDB

SDB

SDA

RDA

SDB

RDB

23

Page 34

Chapter 3

Connection and Installation ■ Connecting SYSMAC-C Series Connecting with C200H-LK202 (-V1), C500-LK201-V1, C500-LK203, C120-LK202-V1 Link unit

Twisted pair cable

BL-U1*

Communication board

Twisted pair cable

BL-U1*

SG

3

SG

SG

9

SG

RDB

1

SDA

RDB

8

SDA

RDA

6

SDB

RDA

6

SDB

SDB

5

RDA

SDB

2

RDA

SDA

9

RDB

SDA

1

RDB

FG

7 D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (male) M2.6 screw

3 ■ Connecting SYSMAC-CV Series Connecting with CV-500-LK201, CV500, CV1000, CVM1 PLC

Twisted pair cable

BL-U1*

SG

9

SG

RDB

8

SDA

RDA

6

SDB

SDB

2

RDA

SDA

1

RDB

RS

4

CS

5

D-sub 9-pin (male) M2.6 screw

24

Connecting with C200HW-COM03/COM06

Page 35

Chapter 3

3.2

Connection and Installation

Connecting the BL-U2/N-42 and Wiring This section describes the connection and wiring of the BL-600 Series and peripheral devices when the special power supply unit BL-U2 or N-42 is used.

3.2.1 Connecting the BL-U2/N-42, AC power supply, and BL-600 Series 1. Connect the 24 V DC power supply to the power supply terminals of the BL-U2 or N-42. N-42 R E

C

P O N O F F

T E R M IN A T O R

R

D

S

-2

O W

32

D

E

R

P

O

W

S

R

S

D

R

R

D

E

A

D

R

E

E

R

A

D

E

R

BL-U2

Power supply terminals

Power supply terminals

Power supply terminals

Power supply terminals

24V DC IN

+

-

N.C.

N.C.

N.C.

24V DC IN

+

-

24V DC

24V DC

+

+

CAUTION

Make sure that the power supply provides 24 V DC. If the power supply output is not 24 V DC, it can damage the unit. Note: If the power supply is UL rated, it must provide Class 2 output. 2. Connect the BL-600 Series to the READER port of the BL-U2 or N-42. BL-U2

N-42 Connector

Connector

BL-600 Series

READER port

BL-600 Series

READER port

25

3

Page 36

Chapter 3

Connection and Installation ■ BL-U2/N-42 READER port pin assignment 1 2 3 4 5 D-sub 9-pin (male) DCE specification (defined as terminal) #4-40 screw (female)

6 7 8 9

1

TIM

Trigger input

Signal direction Output

2

RD (RXD)

Sends RS-232C data

Output

3

SD (TXD)

Receives RS-232C data

Input

4

OK

OK signal

Input

5

GND (SG)

Ground (Common ground for respective signal), 6

NG

NG signal

Input

7

RS (RTS)

Ready to send RS-232C data

Input

8

CS (CTS)

Request to send RS-232C data

Output

9

+5 V

+5 V power supply

Output

Pin No.

3

Symbol

Function

Note: Do not extend a power cable. A long power cable can cause a voltage drop, preventing the BL-600 from starting properly.

3.2.2 Terminals of I/O terminal block and connections Terminals of the I/O terminal block The terminals of the I/O terminal block are assigned as shown in the figure. ■ Terminal assignment BL-U2

N-42 R E

C S

O N O F F

T E R M IN A T O R

R

D R

P

-2

O

W

32

D

E P

O

W

S

R

S

D

R

R

E

D

A

D

E

R E

R

A

D E

R

TIM COM OK NG COM

Trigger input OK/NG output

I/O terminal block

I/O terminal block

Symbol

Description

Signal direction

TIM

Trigger input

Input

COM

Common terminal for trigger input

Input

OK

OK output

Output

NG

NG output

Output

COM

Common terminal for output

Output

Applicable terminals Use the following solderless contact pin (I-terminal) for connection.

2.0 mm max.

5 mm max.

6 mm min

Recommended product Manufacturer: Japan Solderless Terminal (J.S.T.) Mfg. Co., Ltd. Model: VTUB-1.25

26

Page 37

Chapter 3

Connection and Installation

Connecting trigger input The trigger input allows the BL-600 to start reading bar codes (turn on the laser beam). To turn ON the trigger input, supply 15 to 26 V DC between the trigger input terminals. Circuit diagram

BL-U2, N-42 TIM COM OK

Internal circuit

TIM

+ Contact or solid-state

+

+

COM

+

3

15 to 26 V DC

■ Connection to a photoelectric sensor manufactured by KEYENCE BL-U2, N-42 TIM COM OK

Photoelectric sensor Brown (Red) Black (White) Blue (Black) +

Connecting the OK/NG output

The OK/NG output is used to differentiate between acceptable and unacceptable results based on a comparison with preset data. (➮ See page 101.) It can also be used to indicate whether or not the BL-600 Series successfully reads bar codes when there is no preset data entered. The OK/NG output is an NPN open-collector output. Circuit diagram

BL-U2, N-42

OK/NG

Internal circuit

* Rated load: 30V DC max. OK NG COM (100 mA)

+

Load

Load COM

Load

+

■ Connection to a programmable logic controller (PLC) manufactured by KEYENCE BL-U2, N-42 OK NG COM PLC

0001 0000 +

C

27

Page 38

Chapter 3

Connection and Installation

3.2.3 Connecting RS-232C (BL-U2) Pin assignment of the RS-232C port The BL-U1 has a RS-232C port with the following pin assignment.

6 7 8 9

3

*

C 32

D

-2 S R

R

D

E

S

O W

D-sub 9-pin (male) DTE specification (defined as terminal) #4-40 screw (female)

P

1 2 3 4 5

R

R

E

A

D

E

R

■ RS-232C port pin assignment

RS-232C port

Pin No.

Symbol

2

RD (RXD)

Receive data

Signal direction Input

3

SD (TXD)

Send data

Output

4

ER (DTR)

Connected to pin No.6 inside.

Output

5

SG

Signal ground

6

DR (DSR)

Connected to pin No.4 inside.

Input

7

RS (RTS)

Request to send data (always ON)

Output

8

CS (CTS)

Enable to send data

Input

Function, One connector is provided.

Wiring the RS-232C cable Connect the BL-U1 to a personal computer or other devices with the following wiring. ■ Connecting a PC 9-pin serial port PC

25-pin serial port PC

BL-U2

Connector case

Connector case

FG

1

2

2

RD

SD

2

2

RD

SD

3

3

SD

RD

3

3

SD

RS

7

7

RS

RS

4

7

RS

CS

8

8

CS

CS

5

8

CS

ER

4

4

ER

DR

6

4

ER

DR SG

6

6

DR

6

DR

5

5

SG

ER 20 SG 7

5

SG

D-sub 9-pin (female) #4-40 screw

* KEYENCE option cable OP-27937 (2 m) can be used.

D-sub 25-pin (male) M2.6 screw

Communication port

BL-U2

SD

3

2

RD

RD

5

3

SD

4 RJ11

4

ER

6

DR

7

RS

8

CS

5

SG

D-sub 9-pin (female) #4-40 screw

* KEYENCE option OP-96368 (2.5 m) and OP-96369 (conversion connector) can be used.

D-sub 9-pin (female) #4-40 screw

* KEYENCE option OP-22149 (1.5 m) or OP-25057 (conversion connector) can be used.

■ Connecting NEW KV Series/Communication port KV-10/16/24/40

28

Connector case

RD

D-sub 9-pin (female) #4-40 screw

SG

BL-U2

Page 39

Chapter 3 ■ Connecting KV-L2* Port 1 KV-L2*

Connection and Installation

Port 2

BL-U2

KV-L2*

BL-U1*

FG

1

SD

2

2

RD

SD

3

2

RD

RD

3

3

SD

RD

5

3

SD

RS

4

7

RS

7

RS

CS

5

8

CS

8

CS

DR

6

4

ER

4

ER

ER 20 SG 7

6

DR

6

DR

5

SG

5

SG

D-sub 25-pin (male) M2.6 screw

Connector case

D-sub 9-pin (female) #4-40 screw

Connector case

SG

1

Terminal block

D-sub 9-pin (female) #4-40 screw

* KEYENCE option OP-22149 (1.5 m) and OP-25057 (conversion connector) can be used.

■ Connecting MELSEC-A Series Connection with AJ71(U)C24(-S■), AJ71QC24-R2, A0J2-C214-S1 Link unit

BL-U2

3 Connection with A1SJ71(U)C24-R2/PRF, A2CCPUC24(-PRF)

Link unit

BL-U2

FG

1

SD

2

2

RD

RD

2

2

RD

RD

3

3

SD

SD

3

3

SD

RS

4

7

RS

RS

7

7

RS

CS

5

8

CS

CS

8

8

CS

DR

6

4

ER

ER

4

4

ER

SG

7

5

SG

DR

6

6

DR

CD

8

6

DR

SG

5

5

SG

CD

1

Connector case

ER 20 D-sub 25-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

Connector case

Connector case

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

29

Page 40

Chapter 3

Connection and Installation ■ SYSMAC-C Series Connection with C200H-LK201(-V1), C500-LK203, C500-LK201-V1, C120-LK201-V1 Link unit FG

1

SD

2

RD

3

PLC

BL-U2

BL-U2 Connector case

Connector case

FG

1

2

RD

SD

2

2

RD

3

SD

RD

3

3

SD

4

7

RS

RS

4

7

RS

RS

CS

5

8

CS

CS

5

8

CS

SG

7

5

SG

SG

7

5

SG

D-sub 25-pin (male) M2.6 screw

3

Connection with C20H, C28H, C40H

D-sub 9-pin (female) #4-40 screw

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

* KEYENCE option OP-22149 (1.5 m) and OP-25057 (conversion connector) can be used.

Connection with C-200HS-CPU21/23/31/33, CQM1-CPU21/41/42/43/44, C-200HE-CPU32/42, C200HG-CPU33/43/53/63, C200HW-COM02/COM04/COM05/COM06 C200HX-CPU34/44/54/64, C200HX-CPU65-Z/85-Z PLC

BL-U2 Connector case

FG

1

SD

2

2

RD

RD

3

3

SD

RS

4

7

RS

CS

5

8

CS

SG

9

5

SG

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

■ SYSMAC-CV Series Connection with CV500-LK201(Port 1)

Link unit

PLC

BL-U2

BL-U2 Connector case

Connector case

FG

1

2

RD

SD

2

2

RD

3

3

SD

RD

3

3

SD

RS

4

7

RS

RS

4

7

RS

CS

5

8

CS

CS

5

8

CS

SG

7

5

SG

SG

9

5

SG

FG

1

SD

2

RD

D-sub 25-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw

* KEYENCE option OP-22149 (1.5 m) and OP-25057 (conversion connector) can be used.

30

Connection with CV500-LK201 (Port 2), CV500, CV1000, CVM1

D-sub 9-pin (male) M2.6 screw

D-sub 9-pin (female) #4-40 screw