Page 21

Chapter 2

Overview

■ BL-U2 8

R D

S

D

P O W E R

1

R S -2 32 C

R E A D E R

7 6

5

2 3

2

4

8

No.

Name

Function

1

READER port

Connect to a BL-600 Series bar code reader.

2

TRIGGER input terminals

Connect to a photoelectric sensor for trigger input.

3

OK/NG output terminals

Output OK/NG signals.

4

Power supply terminals

Connect to a 24 V DC power supply.

5

RS-232C port

6

Communication status indicator LEDs

7

POWER LED

Connect to a personal computer, etc. • Indicate the communication status of the RS-232C. • The SD and RD indicators are provided in this order from the top. Light when the power is on.

8

Mounting hole

Used when the BL-U2 is mounted with screws.

■ N-42 8

S D

R D

R E A D E R

1

9

P O W E R

7

N F F

6

O

R E T

O

M

IN

AT O R

2 3 4

No.

5 9

Name

Function

1

READER port

2

Terminator switch

3

TRIGGER input terminals

Connect to a BL-600 Series bar code reader. Turns ON/OFF the terminator (Termination resistance: 100 Ω). Connect to a photoelectric sensor for trigger input.

4

OK/NG output terminals

Output OK/NG signals.

5

Power supply terminals

Connect to a 24 V DC power supply.

6

RS-422A terminals

7

Communication status indicator LEDs

8

POWER LED

Connect to an RS-422A device. • Indicates the communication status of the RS-422A. • The SD and RD indicators are provided in this order from the left. Light when the power is turned ON.

9

Mounting hole

Used when the N-42 is mounted with screws.

11

Page 22

Chapter 2

2.3

Overview

System Configuration and Connection/Operation Procedures This section describes the basic system configuration and the connection/operation procedures to use RS-232C, RS-422A, or multi-drop link.

2.3.1 Basic system configuration and connection/operation procedures for RS-232C communication

2

BL-600 Series BL-600/601/600HA/601HA

BL-650HA/651HA

6 Installation

➮ See pages 72 to 80.

LA R ON SE LA G /N OK G IN TIM

SE

• •

R ON

OK

/N TIM G IN G

TE

ST

TE

ST

•

1

▼

Check before installation Position adjustment using test mode Installation

Connection to the READER port With the BL-U1 ➮ See page 16. With the BL-U2 ➮ See page 25.

▼

Optional power supply unit

2 DIP switch setting ➮ See page 17.

Trigger input Photoelectric sensor

BL-U2 C 32

D

-2 S

D

R

E

R

P

O

W

S

R

R

E

A

D

E

R

BL-U1

7

Connection With the BL-U1 ➮ See page 19. With the BL-U2 ➮ See page 27.

▼

4 Power-up Connection With the BL-U1

▲ Serial communi- ▲ PLC link cation

3 ➮ See pages 20 to 23. 8 ➮ See “Chapter 7, With the BL-U2

9

Serial Communication.”

➮ See pages 28 to 30.

▼

▼ Host computer PC

12

5

Setting of the BL-600 Series (Use one of these setup tools.)

PLC (RS-232C link unit)

▼

➮ See “Chapter 8, PLC Link.”

Setup tools Setup software BL-H60WE ➮ See “Chapter 4, Setup Software.”

Page 23

Chapter 2

Overview

2.3.2 Basic system configuration and connection/operation procedures for RS-422A communication BL-600 Series BL-600/601/600HA/601HA

BL-650HA/651HA

6 Installation

➮ See pages 72 to 80.

LA

LA

SE

OK

R ON

/N

TIM

SE

• •

R ON

OK

/N TIM G IN G

G

IN

G

TE

ST

TE

ST

•

1

▼

Check before installation Position adjustment using test mode Installation

Connection to the READER port With the BL-U1 ➮ See page 16. With the BL-N42 ➮ See page 25.

▼

Optional power supply unit

7

Connection With the BL-U1 ➮ See page 19. With the BL-N42 ➮ See page 27.

2 DIP switch setting

Photoelectric sensor

C -2 32

D

R

S

S D R

P

O

W

E R

R

E A

D

E R

➮ See page 17.

Trigger input

▼

Setting of the BL-600 Series (Use one of these setup tools.)

4 Power-up Connection With the BL-U1 ➮ See pages 23 to 24.

3 With the BL-N42

▲ Serial communi- ▲ cation

8 ➮ See “Chapter 7,

➮ See pages 31 to 32.

▼

5

9

PLC link

Setup tools Setup software BL-H60WE ➮ See “Chapter 4, Setup Software.”

➮ See “Chapter 8, PLC Link.”

Serial Communication.”

▼

▼

Host computer PC

PLC (RS-422A link unit)

Note: When the N-42 is used as a power supply unit, the communication type is set to RS-422A, therefore the BL-600 Series cannot be connected directly to a personal computer. To set the BL-600 Series with a personal computer, use an RS-232C type power supply unit (BL-U1 or BL-U2).

13

2

Page 24

Chapter 2

Overview

2.3.3 Multi-drop link communication (RS-485) The following devices are required for the multi-drop link to control several BL-600 Series units with a host computer.

Host computer (PC) Photoelectric sensor (PZ2 Series, etc.)

BL-600 Series

2

Multi-drop controller (N-400)

Optional power supply unit (BL-U1, N-48)

■ BL-600 Series setup tools Setup software BL-H60WE

■ N-400 setup tools Setup software (Provided with N-400)

➮

14

Refer to the N-400 User’s Manual for connection and usage of the multi-drop link.

Page 25

Chapter 3 Connection and Installation This chapter describes the connections and wiring between the BL-600 Series, special power supply unit, and peripheral devices.

3.1

Connecting BL-U1 and Wiring ........................................... 16

3.1.1 Connecting the BL-U1, AC power supply, and BL-600 Series ................................................................. 16 3.1.2 DIP switch setting .................................................................. 17 3.1.3 Terminals of I/O terminal block and wiring ............................. 18 3.1.4 Connecting RS-232C ............................................................. 20 3.1.5 Wiring the RS-422A ............................................................... 23 3.2

Connecting the BL-U2/N-42 and Wiring ............................ 25

3.2.1 Connecting the BL-U2/N-42, AC power supply, and BL-600 Series ................................................................. 25 3.2.2 Terminals of I/O terminal block and connections ................... 26 3.2.3 Connecting RS-232C (BL-U2) ............................................... 28 3.2.4 Connecting the N-42 to RS-422A .......................................... 31 3.3

Wiring without the Special Power Supply Units .............. 33

3.3.1 Pin assignments of the BL-600 Series connector and the connecting power supply .......................................... 33 3.3.2 I/O Wiring ............................................................................... 34 3.3.3 RS-232C connection .............................................................. 35

Page 26

Chapter 3

3.1

Connection and Installation

Connecting BL-U1 and Wiring This section describes the connection and wiring of the BL-600 Series and peripheral devices when the special power supply unit BL-U1 is used.

3.1.1 Connecting the BL-U1, AC power supply, and BL-600 Series 1. Plug the BL-U1 power cable into an outlet. Outlet

BL-U1

Power plug

3 FG line

CAUTION

Do not use a power supply other than 100 to 240 V AC (50/60 Hz). An improper power supply may cause product failure. Note: If the noise conveyed through the FG line causes an LB-600 Series reading error, do not connect the FG line. 2. Connect the BL-600 Series to the READER port of the BL-U1. ■ BL-U1 READER port pin assignment 1 2 3 4 5 BL-600 Series READER port

6 7 8 9 D-sub 9-pin (male) DCE specification (defined as terminal) #4-40 screw (female)

Connector

1

TIM

Trigger input

Signal direction Output

2

RD (RXD)

Sends RS-232C data.

Output

3

SD (TXD)

Receives RS-232C data.

Input

4

OK

OK

Input

5

GND (SG)

Ground (Common ground for respective signal)

––

6

NG

NG

Input

7

RS (RTS)

Input

8

CS (CTS)

9

+5 V

Ready to send RS-232C data. Request to send RS-232C data. (Control method can be selected with the DIP switches.) ➮ See page 17. +5 V power supply

Pin No.

Symbol

Function

Output Output

Note: Do not extend the power cable. A long power cable can cause a voltage drop, preventing the BL-600 from starting properly.

16

Page 27

Chapter 3

Connection and Installation

3.1.2 DIP switch setting Change the DIP switch setting according to the type of communication and terminator setting. ■ DIP switch Switch

OFF

ON

1

2

3

4

5

6

* The figure above shows the factory-settings.

DIP Switch No.

Communication type selection

RS-422A terminator (Termination resistance: 100 Ω) RS-485 terminator (Termination resistance: 100 Ω)

RS-232C (Factory-setting) RS-422A RS-485 (Multi-drop link)

DIP switch

1

2

3

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

4

OFF

OFF

ON

ON

5

OFF

OFF

ON

ON

ON or OFF according Selection of READER to the RS-232C port port CS control method CS signal status. Normally ON

6

OFF ON

17

3

Page 28

Chapter 3

Connection and Installation

3.1.3 Terminals of I/O terminal block and wiring Terminals of the I/O terminal block The terminals of the I/O terminal block are assigned as shown in the figure.

Open

I/O terminal block

■ Terminal assignment

3

TIM

+12V OUT- COM OK

Trigger input

NG

SDA SDB

OK/NG output

SG

RDA RDB

RS-422A/RS-485

Power supply for the sensor (12 V DC, 300 mA)

Symbol

Signal direction Input

Description

TIM

Trigger input

+12 V OUT-

Input

+ terminal of power supply for sensor (12 V DC, 300 mA)

Output

– terminal of power supply for sensor (0 V)

Output

COM

Common terminal for OK/NG output, OK

OK output

Output

NG

NG output

SDA

+ terminal for RS-422A data transmission/RS-485 + terminal

SDB

– terminal for RS-422A data transmission/RS-485 - terminal

Output Output, Input/Output Output, Input/Output, SG

Signal ground

RDA

+ terminal for RS-422A data reception

Input

RDB

– terminal for RS-422A data reception

Input

Applicable crimp terminals M3.0 screws are used for the terminal block. Use the following crimp terminal for connection. ■ Shape of applicable crimp terminal Round-shape 6.0 mm or less

18

Fork-shape 6.0 mm or less

Page 29

Chapter 3

Connection and Installation

Connecting trigger input The trigger input allows the BL-600 Series to start reading bar codes (turn on the laser beam). The trigger input is turned ON when 8.5 to 30 V DC input is activated between the trigger input terminals. The BL-U1’s power supply terminals for the sensor can be used as the power supply input for the sensor. TIM

+12 V OUT–

Contact or solid-state

+ + 8.5 to 30 V DC

3

■ Connection to a photoelectric sensor manufactured by KEYENCE TIM

+12 V OUT–

Photoelectric sensor Brown (Red) Black (White) Blue (Black)

Connecting the OK/NG output The OK/NG output is used to differentiate between acceptable and unacceptable results based on a comparison with preset data (➮ See pages 101.). It can also be used to indicate whether or not the BL-600 Series successfully reads bar codes when there is no preset data entered. The OK/NG output is an NPN open-collector output. COM OK

NG *Rated load: 30 V DC max. (100 mA) Load Load

+

■ Connection to a programmable logic controller (PLC) manufactured by KEYENCE COM OK NG PLC 0001 0000 C +

19

Page 30

Chapter 3

Connection and Installation

I/O circuit diagram ■ Input circuit diagram

■ Output circuit diagram

2.4 kΩ

+

Internal circuit

TIM

+

Internal circuit

3.3 kΩ

OK/NG

Load

+

COM

3 3.1.4 Connecting RS-232C Pin assignment of the RS-232C port The BL-U1 has a RS-232C port with the following pin assignment. ■ RS-232C port pin assignment 13

1

25

14

D-sub 25-pin (female) DTE specification (defined as terminal) M2.6 screw (female)

1

FG

Frame ground

Signal direction, 2

SD (TXD)

Sends RS-232C data

Output

3

RD (RXD)

Receives RS-232C data

Input

4

RS (RTS)

Request to send RS-232C data (always ON)

Output

5

CS (CTS)

Ready to send RS-232C data

Input

6

DR (DSR)

Connected to pin No. 20 inside.

Input

7

GND (SG)

Signal ground, 20

ER (DTR)

Connected to pin No. 6 inside.

Pin No.

20

RS-232C port

Symbol

Function

Output