The text of a manual · part 9 of 12
BL-600 Series User's Manual: Laser Bar Code Reader, pages 81 to 90
Pages 81 to 90 of 112
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-600 and Keyence BL-601
Page 81
Appendices
Angular characteristics (Typical) Model BL-600/601 BL-600HA/601HA BL-650HA/651HA
Narrow bar width 0.19 mm
-60° to -10°, -10° to +60°
± 40°
± 50°
0.5 mm
-60° to -10°, -10° to +60°
± 50°
± 50°
Skew
Pitch
Tilt
0.125 mm
-60° to -10°, -10° to +60°
± 30°
± 50°
0.25 mm
-60° to -10°, -10° to +60°
± 50°
± 50°
0.125 mm
-80° to -30°, -10° to +40°
± 40°
± 50°
0.25 mm
-80° to -30°, -10° to +40°
± 50°
± 50°
Measuring conditions • Bar code: KEYENCE standard bar code • Reading distance: 120 mm (BL-600/601) 90 mm (BL-600HA/601HA) 65 mm (BL-650HA/651HA) Note: The skew angle of -10° to +10°(-30° to -10° in BL-650HA/651HA) is the specular reflection range. In this range, bar codes cannot be read, or reading error may occur. Be sure not to mount the BL-600 Series at the above skew angles. Skew BL-600/601/600HA/601HA
BL-650HA/651HA
-
0°
-
0°
+
+
LASER ON
OK/NG
TIMING
TEST
17°
LASER ON OK/NG TIMING
TEST
Pitch
Tilt
+
+ 0°
0°
-
151
Appendices
Appendix A.3
Page 82
Appendices
Appendix B BL-U1 Specifications Model
BL-U1
Power supply for bar code reader Power supply for sensor Trigger input
OK/NG output
Input rating Max. OFF current
0.5 mA NPN open-collector
Rated load
30 V DC, 100 mA
Leakage current (at OFF)
0.1 mA max.
Residual voltage (at ON)
1 V max. RS-232C, RS-422A, RS-485 multidrop (Up to 31 units can be connected. Max. cable extension: 1.2 km) 0 to 50°C (32 to 122°F), No freezing
Ambient temperature Relative humidity Ambient atmosphere Vibration Noise immunity
35 to 85%, No condensation No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours respectively 1000 V p-p, 1 µs (Power line)
Power supply voltage
100 to 240 V AC (50/60 Hz)
Current consumption
40 VA (100 V AC), 50 VA (240 V AC)
Weight
Appendices
12 V DC ± 10% (300 mA) 8.5 to 30 V DC, 10 mA max.
Output type
Interface
152
5 V DC± 5% (1.5 A)
Approx. 615 g (including cable)
Page 83
Appendices
Appendix C BL-U2, N-42 Specifications Model
BL-U2
Power supply for bar code reader Trigger input
OK/NG output
Input rating
N-42
5 V DC ± 5% (630 mA) 15 to 26V DC, 10 mA max.
Maximum OFF current
1.0 mA
Output type
NPN open-collector
Rated load
30 V DC, 100 mA
Leakage current (at OFF)
0.1 mA max.
Residual voltage (at ON)
1 V max.
Interface Ambient temperature Relative humidity Ambient atmosphere Vibration Power supply voltage
RS-422A (Maximum extension distance: 1.2 km) 0 to 50°C (32 to 122°F), No freezing
Conforms to EIA RS-232C.
35 to 85%, No condensation No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively 24 V DC +-2100%% 250 mA max.
260 mA max.
Weight
Approx. 80 g
Approx. 100 g
Appendices
Current consumption
153
Page 84
Appendices
Appendix D Dimensions ■ BL-600/601/600HA/601HA 30 29.3
13.3
Laser beam
31
2-ø3 Depth 4 3.5
22.5
21
3.8
3.5
24.3
40
33
Center of scanning
15 min.
12.2
9.5
ø4.5 Cable lenght: 1.8 m
■ BL-650HA/651HA * The laser beam application angle is 17°±3° with reference to a line perpendicular to the rear surface of the unit. 17°
18.9
Appendices
17.6
Laser beam
40.7 Center of scanning
21
3.5
2-ø3 Depth 4
48
154
12.3
3.8
3.5
24.3
48
38.1
22
9.5
ø4.5 Cable length: 1.8 m
Page 85
Appendices ■ BL-600/601/600HA/601HA (Mounting bracket) * Use M4 screws to mount the BL-600 unit. • When bracket A is used 6.9
• When bracket B is used Laser beam 15°
6.5 3
5.5 25
3
5.3
2-R2.75
3
2-R2.75
40 26.5
5° 10°
5.5
14 9
R19
36.2
43.4
6
2-R2.65
37.8 2-R2.65 5.3
59.6
44.5
Laser beam
25.5 2.2
2.2
11.4
19.6
32.8
15°
49.5
■ Mounting bracket for the BL-600/601/600HA/601HA • When bracket A is used 32 25 3 2-R2.75
Appendices
1.6
R19 10° 5°
5.5
5.5 9 14
2-R2.75
3.5
59.6
33
22.5
23.1
2-ø3.3
2.2
31
155
Page 86
Appendices
34 36.6
14.5 2-R2.65
3.5
7.5
40 33
3
2 6 .5
3
5.3
1.6
2.2
• When bracket B is used
22.5
5
2-R2.65 5.3 6.5
2-ø3.3
■ BL-/650HA/651HA (Mounting bracket) * Use M4 screws to mount the BL-600 unit. • Vertical scanning 36 3
11 3
5.3
2-R2.65
5.5 36 2-R2.65 5.3
18.9 40.7
3 2-R2.65
38.5 11 3 21
5.3
21
38.5
5.5 2-R2.65
• Horizontal scanning
17° Laser beam 21 1.6
5.3
60.3 19.6
19.6
67.6
67.6
Laser 17° beam
2.2
2.2
48
48
3.8
5.5 5.3
36
11
5.3
3
3 2-R2.65
11 17.5
Appendices
■ Mounting bracket for the BL-650HA/651HA
2-R2.65
22
3.5
1.6
2.2
23.1
22
67.6 38.1
4-ø3.3
6.4
156
38.1 48
21 18.9 1.6
Page 87
Appendices ■ BL-U1*
100 to 240 V AC (with 3-core plug) ø6.5, Cable length: 2 m
Approx. 40
98 110
90
120° 4 - ø5 mounting hole 150 186
4
51 91 max.
4
Note: BL-U1 is not available in Europe.
■ BL-U2
(70)
43.2
Appendices
5.5
2-ø4.5 mounting hole
55
5.9 5.9
63.2 75
5.5 (70)
21
157
Page 88
7) a, =| = o 2 = 4
Appendices mounting hole m N-42 A Ol O fel 43.2 le) O [© [Qgjajgjo 5.9 5.9 63.2 75 a) (f M4 Al, 5.5 55 ]
158
Page 89
Appendices
Appendix E Sample Program for the PLC Link The sample program stores the read data in D105 (DM105) and subsequent DMs. You can change the program to suit your application. Before using the sample program, check that your system meets the following requirements. ■ BL-600 settings • The scan method is “level signal trigger”. • Use the “PLC trigger area”. • The DM head address is “0000”.
Appendices
■ Processing of data memory flag ... Sequential processing * This sample program uses the level signal trigger. However, it does not use the +05 trigger input response area to check if the BL-600 successfully recognized the +04 reading trigger area.
159
Page 90
Appendices ■ Program for the MELSEC-A Series M9038 MOV
K100
D0
MOV
K2
D100
MOV
K1
D4
MOV
K0
D4
Specify the head address of the data memory area. Enter “2” in the data memory flag. (Use sequential processing to process the flag.)
X0 X0
LD= D100 K3
Data stored in D105 and subsequent areas is processed. MOV
K2 D100
Enter “X0” for the reading trigger input.
When D100 becomes “3”, the specified processing is performed. After processing is completed, enter “2” in D100.
END
■ Program for the SYSMAC-C 25315 (A50015)
MOV #0064 DM0000
MOV #0002 DM0100 0000
Enter “2” in the data memory flag. (Use sequential processing to process the flag.)
MOV #0001 DM0004
0000
Specify the head address of the data memory area (DM100). The BL-600 processes data as binary data. Specify each DM number in binary format.
MOV #0000
Enter “0000” for the reading trigger input.
Appendices
DM0004 25313 (A50013)
CMP DM0100 #0003
25506 (A50016)
Data stored in DM0105 and subsequent areas is processed.
When DM0100 becomes “3”, the specified processing is performed. After processing is completed, enter “2” in DM0100.
MOV #0002 DM0100 END
*
160
The descriptions in parentheses are the cases for the CV Series.