Page 81

Appendices

Angular characteristics (Typical) Model BL-600/601 BL-600HA/601HA BL-650HA/651HA

Narrow bar width 0.19 mm

-60° to -10°, -10° to +60°

± 40°

± 50°

0.5 mm

-60° to -10°, -10° to +60°

± 50°

± 50°

Skew

Pitch

Tilt

0.125 mm

-60° to -10°, -10° to +60°

± 30°

± 50°

0.25 mm

-60° to -10°, -10° to +60°

± 50°

± 50°

0.125 mm

-80° to -30°, -10° to +40°

± 40°

± 50°

0.25 mm

-80° to -30°, -10° to +40°

± 50°

± 50°

Measuring conditions • Bar code: KEYENCE standard bar code • Reading distance: 120 mm (BL-600/601) 90 mm (BL-600HA/601HA) 65 mm (BL-650HA/651HA) Note: The skew angle of -10° to +10°(-30° to -10° in BL-650HA/651HA) is the specular reflection range. In this range, bar codes cannot be read, or reading error may occur. Be sure not to mount the BL-600 Series at the above skew angles. Skew BL-600/601/600HA/601HA

BL-650HA/651HA

-

0°

-

0°

+

+

LASER ON

OK/NG

TIMING

TEST

17°

LASER ON OK/NG TIMING

TEST

Pitch

Tilt

+

+ 0°

0°

-

151

Appendices

Appendix A.3

Page 82

Appendices

Appendix B BL-U1 Specifications Model

BL-U1

Power supply for bar code reader Power supply for sensor Trigger input

OK/NG output

Input rating Max. OFF current

0.5 mA NPN open-collector

Rated load

30 V DC, 100 mA

Leakage current (at OFF)

0.1 mA max.

Residual voltage (at ON)

1 V max. RS-232C, RS-422A, RS-485 multidrop (Up to 31 units can be connected. Max. cable extension: 1.2 km) 0 to 50°C (32 to 122°F), No freezing

Ambient temperature Relative humidity Ambient atmosphere Vibration Noise immunity

35 to 85%, No condensation No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours respectively 1000 V p-p, 1 µs (Power line)

Power supply voltage

100 to 240 V AC (50/60 Hz)

Current consumption

40 VA (100 V AC), 50 VA (240 V AC)

Weight

Appendices

12 V DC ± 10% (300 mA) 8.5 to 30 V DC, 10 mA max.

Output type

Interface

152

5 V DC± 5% (1.5 A)

Approx. 615 g (including cable)

Page 83

Appendices

Appendix C BL-U2, N-42 Specifications Model

BL-U2

Power supply for bar code reader Trigger input

OK/NG output

Input rating

N-42

5 V DC ± 5% (630 mA) 15 to 26V DC, 10 mA max.

Maximum OFF current

1.0 mA

Output type

NPN open-collector

Rated load

30 V DC, 100 mA

Leakage current (at OFF)

0.1 mA max.

Residual voltage (at ON)

1 V max.

Interface Ambient temperature Relative humidity Ambient atmosphere Vibration Power supply voltage

RS-422A (Maximum extension distance: 1.2 km) 0 to 50°C (32 to 122°F), No freezing

Conforms to EIA RS-232C.

35 to 85%, No condensation No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively 24 V DC +-2100%% 250 mA max.

260 mA max.

Weight

Approx. 80 g

Approx. 100 g

Appendices

Current consumption

153

Page 84

Appendices

Appendix D Dimensions ■ BL-600/601/600HA/601HA 30 29.3

13.3

Laser beam

31

2-ø3 Depth 4 3.5

22.5

21

3.8

3.5

24.3

40

33

Center of scanning

15 min.

12.2

9.5

ø4.5 Cable lenght: 1.8 m

■ BL-650HA/651HA * The laser beam application angle is 17°±3° with reference to a line perpendicular to the rear surface of the unit. 17°

18.9

Appendices

17.6

Laser beam

40.7 Center of scanning

21

3.5

2-ø3 Depth 4

48

154

12.3

3.8

3.5

24.3

48

38.1

22

9.5

ø4.5 Cable length: 1.8 m

Page 85

Appendices ■ BL-600/601/600HA/601HA (Mounting bracket) * Use M4 screws to mount the BL-600 unit. • When bracket A is used 6.9

• When bracket B is used Laser beam 15°

6.5 3

5.5 25

3

5.3

2-R2.75

3

2-R2.75

40 26.5

5° 10°

5.5

14 9

R19

36.2

43.4

6

2-R2.65

37.8 2-R2.65 5.3

59.6

44.5

Laser beam

25.5 2.2

2.2

11.4

19.6

32.8

15°

49.5

■ Mounting bracket for the BL-600/601/600HA/601HA • When bracket A is used 32 25 3 2-R2.75

Appendices

1.6

R19 10° 5°

5.5

5.5 9 14

2-R2.75

3.5

59.6

33

22.5

23.1

2-ø3.3

2.2

31

155

Page 86

Appendices

34 36.6

14.5 2-R2.65

3.5

7.5

40 33

3

2 6 .5

3

5.3

1.6

2.2

• When bracket B is used

22.5

5

2-R2.65 5.3 6.5

2-ø3.3

■ BL-/650HA/651HA (Mounting bracket) * Use M4 screws to mount the BL-600 unit. • Vertical scanning 36 3

11 3

5.3

2-R2.65

5.5 36 2-R2.65 5.3

18.9 40.7

3 2-R2.65

38.5 11 3 21

5.3

21

38.5

5.5 2-R2.65

• Horizontal scanning

17° Laser beam 21 1.6

5.3

60.3 19.6

19.6

67.6

67.6

Laser 17° beam

2.2

2.2

48

48

3.8

5.5 5.3

36

11

5.3

3

3 2-R2.65

11 17.5

Appendices

■ Mounting bracket for the BL-650HA/651HA

2-R2.65

22

3.5

1.6

2.2

23.1

22

67.6 38.1

4-ø3.3

6.4

156

38.1 48

21 18.9 1.6

Page 87

Appendices ■ BL-U1*

100 to 240 V AC (with 3-core plug) ø6.5, Cable length: 2 m

Approx. 40

98 110

90

120° 4 - ø5 mounting hole 150 186

4

51 91 max.

4

Note: BL-U1 is not available in Europe.

■ BL-U2

(70)

43.2

Appendices

5.5

2-ø4.5 mounting hole

55

5.9 5.9

63.2 75

5.5 (70)

21

157

Page 88 read from a scan by OCR; it may hold reading errors

7) a, =| = o 2 = 4

Appendices mounting hole m N-42 A Ol O fel 43.2 le) O [© [Qgjajgjo 5.9 5.9 63.2 75 a) (f M4 Al, 5.5 55 ]

158

Page 89

Appendices

Appendix E Sample Program for the PLC Link The sample program stores the read data in D105 (DM105) and subsequent DMs. You can change the program to suit your application. Before using the sample program, check that your system meets the following requirements. ■ BL-600 settings • The scan method is “level signal trigger”. • Use the “PLC trigger area”. • The DM head address is “0000”.

Appendices

■ Processing of data memory flag ... Sequential processing * This sample program uses the level signal trigger. However, it does not use the +05 trigger input response area to check if the BL-600 successfully recognized the +04 reading trigger area.

159

Page 90

Appendices ■ Program for the MELSEC-A Series M9038 MOV

K100

D0

MOV

K2

D100

MOV

K1

D4

MOV

K0

D4

Specify the head address of the data memory area. Enter “2” in the data memory flag. (Use sequential processing to process the flag.)

X0 X0

LD= D100 K3

Data stored in D105 and subsequent areas is processed. MOV

K2 D100

Enter “X0” for the reading trigger input.

When D100 becomes “3”, the specified processing is performed. After processing is completed, enter “2” in D100.

END

■ Program for the SYSMAC-C 25315 (A50015)

MOV #0064 DM0000

MOV #0002 DM0100 0000

Enter “2” in the data memory flag. (Use sequential processing to process the flag.)

MOV #0001 DM0004

0000

Specify the head address of the data memory area (DM100). The BL-600 processes data as binary data. Specify each DM number in binary format.

MOV #0000

Enter “0000” for the reading trigger input.

Appendices

DM0004 25313 (A50013)

CMP DM0100 #0003

25506 (A50016)

Data stored in DM0105 and subsequent areas is processed.

When DM0100 becomes “3”, the specified processing is performed. After processing is completed, enter “2” in DM0100.

MOV #0002 DM0100 END

*

160

The descriptions in parentheses are the cases for the CV Series.