Page 71

Chapter 8

PCL Link

A+05 to A+69 Data memory area

•

The number of digits of the data is stored in the +05 address.

•

The read bar code data is stored in the A+06 to A+69 addresses using the ASCII codes (hexadecimal numbers in two digits) by the digit. ➮ See the ASCII code table on page 169.

•

If a read error occurs, the “ERROR” code is stored in the corresponding area. (The reading error code can be easily changed in the BL-600 settings.) ➮ See page 43.

•

If a buffer overflow error occurs with the BL-600, the “OVER” code is stored in the corresponding area.

•

If an error occurs in the main unit, the “MOTOR” code is stored in the corresponding area.

Address

A+06

Description Number of digits of bar code data (1 to 64) 1st digit of read data

Data 1 to 64 (binary) ... Number of digits A single ASCII code

A+07

2nd digit of read data

A single ASCII code

A+05

: A+69

:

:

64th digit of read data

A single ASCII code

Note 1: When test mode is enabled, the BL-600 does not write data. Note 2: These data areas accept up to 64 digits. However, the BL-600 can read only 32 digits. When the bar code type is CODE128 and the start character is CODE-C, up to 64 digits can be read.

Example When the BL-600 reads the bar code “KE12” 4

A+06

$004B

A+07

$0045

A+08

$0031

A+09

$0032

➝

A+05

Number of digits

Stored in ASCII codes (hexadecimal)

8

Example When the BL-600 generates a reading error (ERROR)

5

A+06

$0045

A+07

$0052

A+08

$0052

A+09

$004F

A+10

$0052

➝

A+05

Number of digits

Stored in ASCII codes (hexadecimal)

141

Page 72

Chapter 8

8.4

PLC Link

PLC Link Error This section describes the remedy if a communication error occurs during the PLC link. If an error occurs, the BL-600 Series stops communication. The top LED in the STABILITY indicator flashes. 1. Check the following points and eliminate the cause. 1) Check if the RS-232C communication parameters (baud rate, data length, parity and stop bit length) for the PLC are matched with the N-400’s settings. 2) Check if the PLC link is set to “Use” in the communication parameters 2 setup. 3) Check if the PLC’s settings are correct. ➮ See pages 132 to 134. 4) Check if the cable connections are correct, or if any cable is disconnected. Referring to chapter 2 of this manual, check the connections using a multimeter. 5) Check if the device setting range does not exceed the available data memory areas of the PLC. If the data memory areas used for the BL-600 do not exist in the PLC, communication is impossible. 6) Check if the link unit operates normally. *

For the settings of the link unit, see the instruction manual for the link unit being used.

2. Press the TEST switch of the BL-600 Series. Communication recovers. If the problem cannot be solved in the procedure above, contact your nearest KEYENCE office or distributor (listed at the end of this manual).

8

142

Page 73

Chapter 8

8.5

PCL Link

Communication Time This section describes the communication time required for data transmission between the BL-600 Series and the PLC. ■ Time required data transmission The time required for data transmission from the BL-600 to the PLC is as follows: This communication time may change depending on the PLC’s scan time and the model of the PLC. * When the RS-232C communication baud rate is 9600 bps: Number of data digits

MELSEC-A

SYSMAC-C

KV (KV mode)

10

Approx. 220 ms

Approx. 330 ms

Approx. 440 ms

20

Approx. 270 ms

Approx. 380 ms

Approx. 680 ms

32

Approx. 320 ms

Approx. 460 ms

Approx. 920 ms

■ Communication time to start reading using reading trigger area To control the BL-600 Series’ reading operation using the reading trigger area, enter the trigger ON command on the PLC, and obtain the time duration until the command is received by the BL-600. * When the RS-232C communication baud rate is 9600 bps: MELSEC-A

SYSMAC-C

KV (KV mode)

Approx. 60 ms

Approx. 80 ms

Approx. 30 ms

8

143

Page 74

Chapter 8

8

144

PLC Link

Page 75

Appendices The appendix includes specifications, reading characteristics, dimensions, troubleshooting, and index.

Appendix A BL-600 Series Specifications................................ 146 Appendix A.1 Specifications........................................................... 146 Appendix A.2 Reading range characteristics (Typical) .................. 148 Appendix A.3 Angular characteristics (Typical).............................. 151 Appendix B BL-U1 Specifications ............................................. 152 Appendix C BL-U2, N-42 Specifications ................................... 153 Appendix D Dimensions ............................................................ 154 Appendix E Sample Program for the PLC Link ....................... 159 Appendix F

Troubleshooting .................................................... 162

Appendix F.1 Bar codes cannot be read........................................ 162 Appendix F.2 Reading rate check mode is not 100% .................... 163 Appendix F.3 The setting data cannot be sent/received using the setup software .......................................... 163 Appendix F.4 Cannot communicate successfully when using the PLC link .......................................... 163 Appendix G CODE93 Specifications ......................................... 164 Appendix H CODE128 Specifications ....................................... 165 Appendix I

Checksum Calculation Method ............................ 167

Appendix J

ASCII Code Table ................................................... 169

Appendix K Setup Parameter List ............................................. 170 Appendix L

Default Setting List ................................................ 173

Page 76

Appendices

Appendix A BL-600 Series Specifications Appendix A.1

Specifications

■ General specifications Model

BL-600

Type

BL-601

BL-600HA

Standard type

Scanning direction Light source

High-resolution Front 1.5 mW 99 µs

FDA

Class 2

DIN EN 60825-1 07.1994

Reading distance Reading bar width 1. Maximum reading label width 2. PCS Scan count Supported codes Reading digit Enclosure rating Ambient light Ambient temperature Relative humidity Operating atmosphere Vibration

Klasse 2 Single Raster Single Raster Single Raster 75 to 330 mm 55 to 190 mm 45 to 175 mm (When narrow width is 1.0 mm) (When narrow width is 0.5 mm) (When narrow width is 0.5 mm) 0.19 to 1.0 mm 0.125 to 1.0 mm * 0.25 to 1.0 mm for * 0.15 to 1.0 mm for CODE93 and CODE128 CODE93 and CODE128 250 mm (When 156 mm (When 170 mm (When reading distance is 280 mm) reading distance is 174 mm) reading distance is 155 mm) 0.6 or more (white reflection rate 75% or more) 500 scans/second CODE39, ITF, Industrial2of5, COOP2of5, Coda bar, CODE128, EAN-128, CODE93, EAN / UPC(A•E) 32 digits max. 3. IP-65 Sunlight: 10000 lx Incandescent lamp: 6000 lx 0 to 45°C (32 to 113°F), No freezing 35 to 85%, No condensation No dust or corrosive gas present 10 to 55 Hz, amplitude 1.5 mm, 2 hours each in X, Y and Z directions. 5 V DC ± 5%

Power supply voltage

Appendices

Power consumption Weight

82 µs Class II

Class IEC 825-1 11.1993 Scan method

BL-650HA BL-651HA High-resolution, side-scanning type Side

Visible red semiconductor laser (Wavelength: 650 nm)

Muximum output Pulse width

BL-601HA

330 mA max. Approx. 115 g

Approx. 130 g

1. Reading bar width indicates the range of readable narrow bar width when the bar code type is CODE39. 2. Maximum reading label width includes the bar code margin (quiet zone). 3. When start/stop character of CODE128 is CODE-C, up to 64 digits are allowed. Note: The internal BL settings are written to the built-in EEPROM (erasable up to 100,000 times).

146

Page 77

Appendices ■ Interface specifications

Output type

Non-voltage input (relay contact, solid state) * TTL input is also available. NPN open collector

Rating load

24 V DC, 30 mA

Trigger input

OK/NG output

Leakage current at OFF

0.1 mA max.

Residual voltage at ON

Serial interface

0.5 V max.

Applied standard

In accordance with RS-232C

Synchronization

Start-stop synchronization

Transmission code

Data length

ASCII code 600, 1200, 2400, 4800, 9600, 19200, 31250, 38400 bit/s 7/8 bits

Parity check

None/even/odd

Stop bit length

1/2 bits

Baud rate

Model

Reading distance

Raster width

BL-601

120 mm

7.1 ± 1.8 mm

BL-601H

90 mm

5.5 ± 1.4 mm

BL-651H

65 mm

5.5 ± 1.4 mm

Appendices

■ Raster width specification In raster scan mode, the BL-600 scans multiple positions of the bar code by swinging the laser beams up and down. Thus, the bar code can be read even if it has a stain or missing part. For the up-down width of raster scan (raster width), see the table below.

147

Page 78

Appendices

Appendix A.2

Reading range characteristics (Typical) ■ BL-600/601 Unit: mm Bar code type

Narrow bar width

Reading distance

A

CODE39

0.19

90 to 160

B

CODE39

0.25

75 to 200

C

CODE39

0.5

75 to 290

D

CODE39

1.0

75 to 330

0

100

200

300

Reading distance (mm)

120 (Focal length)

(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 15° • Pitch: 0° • Tilt: 0°

*

250

110

100

0

100

A B C D

Readable label width (mm)

For the reading distance measuring reference, see page 74.

Appendices

Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: It is recommended that the focal length (120 mm) is set as the mounting distance. In this case, the maximum readable label width is 110 mm.

148

Page 79

Appendices ■ BL-600HA/601HA Unit: mm Bar code type

Narrow bar width

Reading distance

A

CODE39

0.125

70 to 105

B

CODE39

0.19

60 to 140

C

CODE39

0.25

55 to 150

D

CODE39

0.5

55 to 190

100

200

0

Reading distance (mm)

90 (Focal length)

(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 15° • Pitch: 0° • Tilt: 0°

0

100 A B C D

Readable label width (mm)

For the reading distance measuring reference, see page 74.

Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: It is recommended that the focal length (90 mm) is set as the mounting distance. In this case, the maximum readable label width is 86 mm.

149

Appendices

*

156

86

100

Page 80

Appendices ■ BL-650HA/651HA Unit: mm Bar code type

Narrow bar width

Reading distance

A

CODE39

0.125

45 to 85

B

CODE39

0.19

45 to 125

C

CODE39

0.25

45 to 140

D

CODE39

0.5

45 to 175

0

100

200

Reading distance (mm)

65 (Focal length)

(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°

*

A B C D

170

96

100

0

100 Readable label width (mm)

For the reading distance measuring reference, see page 74.

Appendices

Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: It is recommended that the focal length (65 mm) is set as the mounting distance. In this case, the maximum readable label width is 96 mm.

150