The text of a manual · part 10 of 12
BL-600 Series User's Manual: Laser Bar Code Reader, pages 91 to 100
Pages 91 to 100 of 112
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-600 and Keyence BL-601
Page 91
Appendices ■ Program for the KV Series
2008
0000
0000
DM0100 LDA
Specify the head address of the data memory area.
#0002 DW DM0100
Enter “2” in the data memory flag. (Use sequential processing to process the flag.)
#0001 DW DM0004 #0000 DW DM0004
Enter “0000” for the reading trigger input.
#0003 CMP
2010
Data stored in DM0105 and subsequent areas is processed.
When DM0100 becomes “3”, the specified processing is performed. After processing is completed, enter “2” in DM0100.
#0002 DW DM0100 END ENDH
Appendices
2002
#0100 DW DM0100
161
Page 92
Appendices
Appendix F Troubleshooting If a problem occurs during operation of the BL-600 Series, please check the following troubleshooting list first. If you cannot fix the problem, contact your nearest KEYENCE office or distributor (listed at the end of this manual).
Appendix F.1
Bar codes cannot be read ● Check whether or not the laser is emitted. • If using the power supply unit BL-U1, BL-U2, N-42 or N-48, check the wiring of the power supply unit, the power switch (BL-U1 only), and the wiring of the trigger input terminal. ➮ See pages 16 to 32. •
Check whether or not the laser off command (➮ See page 116.) has been sent to the BL-600 Series. If so, send the resetting laser off command (UNLOCK) to enable laser emission. If a laser off command has been executed, the bottom LED in the STABILITY indicator flashes.
•
If a optional power supply unit is not used, confirm that the supplied power voltage and capacity (5 V DC±5%, 330 mA min.) is correct. Also, check the wiring of the power supply unit and the trigger input terminal. ➮ See pages 33 to 35.
Note: Connecting the power supply in reverse may damage the product. If the BL600 Series does not operate, contact your nearest KEYENCE office or distributor (listed at the end of this manual). ● Check the bar code settings (type, No. of digits, etc.). Check the following parameters using the setup software. • Bar code type, No. of digits. • Setting of the check digit inspection (enabled or disabled) • Setting of the label orientation-specified reading Note: When using CODE39 or Codabar, include the start/stop characters and check digit in the number of digits. ➮ For CODE93, See page 164. ➮ For CODE128, See page 165.
Appendices
● Check the mounting distance and angle of the BL-600 Series. ➮ See page 74.
● Check the bar code quiet zones (margins). A bar code requires the right and left margins to be at least 10 times wider than the narrow bar width. If the bar code margins are too narrow, it may not be read. ➮ See page 74. ● Check the bar code label length. The bar code label length is the lateral length of a bar code including the right and left margins (quiet zones). The readable bar code label length is limited depending on the reading distance. See “Appendix A.2 Reading range characteristics (Typical)” on page 148 to 150. ● Check the printing quality of the bar code. A bar code with blurred sections, defects or stains may not be read correctly. Bar codes printed with dot matrix or ink jet printers are prone to such problems.
162
Page 93
Appendices ● Check whether the transmitter (light source) and the receiver (optical pickup) are clean. If moisture, oil or dust adheres to the transmitter or the receiver, wipe the units using a soft cloth and a mild plastic cleaner. ● Check the environmental conditions. ➮ See pages ii and 72 to 80 for details.
Appendix F.2
Reading rate check mode is not 100% Check the previous item “Bar codes cannot be read”. Note 1: The reading rate indicates the number of acceptable readings during 100 scans of a bar code. If a bar code has spots or voids, the reading rate is reduced. Note 2: Even If the reading rate is 20%, two readings are acceptable during 10 scans. Therefore, if the decoding match count number is set to “2”, the bar code can be read. The read operation is not affected if the scan time for the bar code is set long enough.
Appendix F.3
The setting data cannot be sent/received using the setup software Is the BL-600 set to “setting data send/receive waiting status”? Press the TEST switch for 8 seconds to enter setting data send/receive waiting status. (The 1st, 3rd and 5th STABILITY LEDs from the top flash.) The BL-600 setup software [[Com port]] must be set as below: • Baud rate: 9600 bit/s • Data length: 7 bits • Parity: Even • Stop bits: 1 bit ● Does the RS-232C pin assignment of the BL-600 (BL-U1 or BL-U2) match that of the PC? Are the cables firmly attached?
● Is RS-232C used for the interface of the BL-U1 DIP switches? ➮ See page 9.
Appendix F.4
Cannot communicate successfully when using the PLC link ➮ For details, see page 130.
163
Appendices
● Is power supplied to the BL-600, BL-U1 or BL-U2?
Page 94
Appendices
Appendix G CODE93 Specifications ■ Setting of No. of Digits • The start/stop character and check digit are not included in the number of digits. ■ Data Transmission • The start/stop characters and check digit cannot be sent. • Control codes are sent. Note: Do not use CODE93 with control codes when using a multi-drop link. Communication errors may occur. ■ Registration of Preset Data • When ! or ? is registered as preset data, it functions as the Preset “!” “?” Function, as described on page 45. Since CODE93 can represent all ASCII codes as bar code data, ! or ? can also be represented as bar code data. To register ! or ? as preset data, send \! or \? to differentiate them from the preset “!” “?” function. To register \ as preset data, send \\.
Example To register 123 \!?ABC as preset data, send the following command. ➮ See page 101.
WP68123 \\\!\?ABC<CR>
Appendices
•
164
Control codes (data in 00h to 2Fh of the ASCII code table, such as <CR> and <STX>), the start/stop characters, and the check digit cannot be registered as preset data. (Data comparison is also impossible.)
Page 95
Appendices
Appendix H CODE128 Specifications ■ Setting No. of Digits • The start/stop character and check digit are not included in the number of digits. •
FNC1 to 4 (Function codes), SHIFT, and CODE-A to -C should not be added to the number of digits.
•
The number of digits setting range varies depending on the start character (CODE-A to -C). CODE-A, B: 1 to 32 CODE-C: 1 to 64 One digit of CODE-A or CODE-B represents two digits of CODE-C.
■ Data Transmission • The start/stop character and check digit cannot be sent. •
FNC1 to 4 (Function codes), SHIFT, and CODE-A to -C cannot be sent.
•
Control codes are sent.
Note: Do not use CODE128 with control codes when you build a multidrop link. Communication errors may occur. ■ Registration of Preset Data • The number of characters that can be registered as preset data is up to 32 digits for CODE-A or CODE-B, and up to 64 digits for CODE-C, as described above. •
When ! or ? is registered as preset data, it functions as the Preset “!” “?” Function, as described on page 18. Since CODE128 can represent all ASCII codes as bar code data, ! or ? can also be represented as bar code data. To register ! or ? as preset data, send \! or \? to differentiate it from the Preset “!” “?” function. To register \ as preset data, send \\.
Appendices
Example To register 123 \!?ABC as preset data, send the following command. ➮ See page 101.
WP68123 \\\!\?ABC <CR> •
Control codes (data in 00h to 2Fh of the ASCII code table, such as <CR> and <STX>), start/stop character, check digit, FNC1 to 4 (function codes), SHIFT or CODE-A to-C cannot be registered as preset data. (Data comparison is also impossible.)
165
Page 96
Appendices ■ EAN-128 reading specifications Start code
FNC1
Data 1 Fixed length
Data 2 Variable length
EAN-128 Start pattern
FNC1
Data 3 Variable length
Check digit
Stop code
Separator
Appendices
The BL-600 Series operates as follows if “EAN-128 support” is selected using the setup software. ➮ See page 52.
166
•
The header of the EAN-128 data is always the combination of a “Start code A to C” and “FNC1” (Start pattern). A reading error occurs when another item is used.
•
“FNC1” (separator) is used at the end of each set of data that has a variable length to separate the data. “FNC1” is replaced with character [GS] (“1Dh” of ASCII code) for output.
Page 97
Appendices
Checksum Calculation Method You can add a checksum to transmitted data. (The checksum cannot be added to a command or a response to a command.) Adding a checksum enables incorrect data translation to be detected in the RS232C communication. If the checksum does not match when the PASS/RTRY or ACK/NAK protocol is used, modify the program so that the “Request to resend” (RTRY or <NAK>) command is sent to the BL-600. To set the checksum, use the “PROTOCOL SETUP” screen of the BL-600 setup software. *
The checksum cannot be added when the PLC link is used.
■ Checksum calculation range and the position to add checksum The checksum calculation is performed with all characters except for the header and delimiter. The checksum is added immediately before the delimiter. CC = Checksum (2 ASCII code characters) •
Data format
Heade Read Data
•
Delimiter
When using the data addition function
Header
•
CC
Code Type
Label
: Orientation : Read Data
:
Decode Count
/ Scan Count CC Delimiter
Test mode
Header
Read Data
:
Reading Rate or Decode Count
CC
Delimiter
Appendices
Appendix I
167
Page 98
Appendices ■ Checksum calculation method Calculate the checksum (CC) using the read data of “ABC123” as an example. Convert each character into the ASCII code as shown below, and express the result as 8-bit binary numbers. Calculate the “Exclusive-OR” of the binary numbers of each bit. Header ABC123
CC
Delimiter
ASCII code
Bit
A ➔ 41h ➔ 0100
0001
B ➔ 42h ➔ 0100
0010
C ➔ 43h ➔ 0100
0011
1 ➔ 31h ➔ 0011
0001
2 ➔ 32h ➔ 0011
0010
3 ➔ 33h ➔ 0011
0011
+
0111
0000
70h
* Based on the “Exclusive OR” logic, when an odd number of “1”s are present, the calculation result is “1”, and when an even number of “1”s are present, the calculation result is “0”.
Convert the calculated hexadecimal number into an ASCII code in two digits. The result obtained is the checksum. Therefore, the checksum for the above example is “CC =70 (37h 30h).
Example Header ERROR
CC
Header KEYENCE :
CC=58
Delimiter
100 %
CC Delimiter
CC=74
Reference 1: Exclusive OR calculation formula Calculate the numbers of each bit, referring to the following formula: 0+0=0 0+1=1 1+0=1 1+1=0 * + : Operator of Exclusive OR
Appendices
Reference 2: Conversion from hexadecimal number into binary number To convert ASCII codes into binary numbers, refer to the following table. Hexadecimal number Binary number Hexadecimal number Binary number
168
0
1
2
3
4
5
6
7
0000 0001 0010 0011 0100 0101 0110 0111 8
9
A
B
C
D
E
F
1000 1001 1010 1011 1100 1101 1110 1111
Page 99
Appendices
Appendix J ASCII Code Table
High-order 4 bits Hexadecimal
0
1
2
3
4
5
6
7
0
0000 NUL DLE (SP)
0
@
P
1
0001 SOH DC1
!
1
A
Q a q
2
0010 STX DC2
”
2
B
R b r
3
0011 ETX DC3
#
3
C
S c s
4
0100 EOT DC4
$
4
D
T d t
5
0101 ENQ NAK
%
5
E
U e u
6
0110 ACK SYN
&
6
F
V f v
7
0111 BEL ETB
’
7
G
W g w
8
1000 BS CAN
(
8
H
X h x
9
1001 HT
EM
)
9
I
Y i y
A
1010 LF
SUB
✽
:
J
Z j z
B
1011 HM ESC
+
;
K
[ k
{
C
1100 CL
FS
,
<
L
\
I
D
1101 CR
GS
–
=
M
] m
}
E
1110 SO
RS
.
>
N n
~
F
1111 SI
US
/
?
O o del
_ p
Appendices
Low-order 4 bits
Binary 0000 0001 0010 0011 0100 0101 0110 0111
169
Page 100
Appendices
Appendix K Setup Parameter List Fill in the specified data for each parameter. Copy the list for daily operation.
Appendices
■ Bar code setup Setup parameter
Code 1
Code type
(
)
(
Code 3 )
(
Code 4 )
(
)
Maximum number of digits (
)
(
)
(
)
(
)
Minimum number of digits (
)
(
)
(
)
(
)
Send start/stop character (CODE39, Coda bar)
■ Don’t send ■ Send
■ Don’t send ■ Send
Start/stop character type (Coda bar)
■ Lowercase ■ Uppercase
■ Lowercase ■ Lowercase ■ Lowercase ■ Uppercase ■ Uppercase ■ Uppercase
Test check digit (CODE39, Coda bar, ITF)
■ Don’t test ■ Test
■ Don’t test ■ Test
Check digit type (Coda bar)
(
Send check digit (CODE39, Coda bar, ITF)
■ Don’t send ■ Send
Read EAN (More than one can be selected.)
■ EAN 13-digit ■ EAN 13-digit ■ EAN 13-digit ■ EAN 13-digit ■ EAN 8-digit ■ EAN 8-digit ■ EAN 8-digit ■ EAN 8-digit ■ UPC-E ■ UPC-E ■ UPC-E ■ UPC-E
)
(
■ Don’t send ■ Send
■ Don’t test ■ Test )
■ Don’t send ■ Send
(
■ Don’t send ■ Send
■ Don’t test ■ Test )
■ Don’t send ■ Send
(
)
■ Don’t send ■ Send
Number of output digits of UPC-A
■ 13 digits ■ 12 digits
■ 13 digits ■ 12 digits
■ 13 digits ■ 12 digits
■ 13 digits ■ 12 digits
Add “0” to UPC-E system code
■ Don’t add ■ Add
■ Don’t add ■ Add
■ Don’t add ■ Add
■ Don’t add ■ Add
CODE EAN-128 support 128
■ Don’t check ■ Check
■ Don’t check ■ Check
■ Don’t check ■ Check
■ Don’t check ■ Check
Set specified-digit output function
■ Don’t set ■ Set
■ Don’t set ■ Set
■ Don’t set ■ Set
■ Don’t set ■ Set
■ Forward ■ Backward
■ Forward ■ Backward
■ Forward ■ Backward
■ Forward ■ Backward
Specified direction
Number of effective ( digits
)
(
)
(
)
(
)
Start digit
)
(
)
(
)
(
)
Set label reading in the specified direction Specified direction
170
Code 2
(
■ Don’t set ■ Set
■ Don’t set ■ Set
■ Don’t set ■ Set
■ Don’t set ■ Set
■ Forward ■ Reverse
■ Forward ■ Reverse
■ Forward ■ Reverse
■ Forward ■ Reverse