The text of a manual · part 2 of 12

BL-600 Series User's Manual: Laser Bar Code Reader, pages 11 to 20

Pages 11 to 20 of 112

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence BL-600 and Keyence BL-601

Page 11

Chapter 5

5.2

Installation

Installation of the Special Power Supply Unit This section describes how to install the special power supply units BL-U1, BL-U2, and N-42.

5.2.1 In-panel installation To mount the power supply unit BL-U1, BL-U2 or N-42, carefully observe the following instructions. • • • •

Provide enough ventilation space. If the ambient temperature may fall below 0°C or exceed 50°C, provide a fan or air conditioner. Do not mount this unit in a panel where a high voltage device is installed. Place this unit as far away from power lines as possible.

5.2.2 Installing the BL-U1 There are 2 methods for installing the BL-U1. ■ Screw mounting 1. Pull out the 4 screw slot tabs from the rear panel of the BL-U1. Pull out the tab.

5

Screw hole tab

Mounting hole (4-ø5)

BL-U1

98mm 150mm

2. Secure the BL-U1 with screws. *

The mounting screws are not included.

Mounting screw

81

Page 12

Chapter 5

Installation ■ DIN-rail mounting 1. Check that the DIN-rail mounting claw is in the condition shown in the figure.

Front view

DIN-rail mounting claw

2. Attach the BL-U1 to the DIN rail as shown in the figure. Fixed claw

DIN rail

5 Mounting the BL-U1 to a DIN-rail 1. Hook the BL-U1 to the rail. DIN rail Fixed claw

2. Push the bottom of the BL-U1 against the rail.

Mounting claw

■ Removal from a DIN rail 1. Pull the mounting claw down until it is in position B. Disengage the BL-U1 from the DIN rail. 2. After removal, push the mounting claw back to position A.

A

B Mounting claw

Pull the claw down using a screwdriver, etc.

82

Page 13

Chapter 5

Installation

5.2.3 Installing the BL-U2 and N-42 Install the BL-U2 and N-42 using screws through the mounting holes. * The mounting screws are not included. Mounting screw

63.2mm

Mounting hole (2-ø4.5mm)

43.2mm BL-U2: 21 mm N-42: 26 mm

5

83

Page 14

Chapter 5

5

84

Installation

Page 15

Chapter 6 Functions for Reading Operation This chapter describes the reading operation and other functions, such as test mode, of the BL-600 Series.

6.1

Read Operation .................................................................... 86

6.1.1 Scanning method ................................................................... 86 6.2

Read Modes .......................................................................... 88

6.2.1 6.2.2 6.2.3 6.2.4

Single label read mode .......................................................... 88 Multi-label read mode 1 (Multi 1) ........................................... 89 Multi-label read mode 2 (Multi 2) ........................................... 90 Multi-label read mode 3 (Multi 3) ........................................... 91

6.3

Label Orientation Mode ....................................................... 93

6.4

Test Mode ............................................................................. 94

6.4.1 Reading rate check mode ...................................................... 94 6.4.2 Tact check mode ................................................................... 97 6.4.3 Online test mode .................................................................... 99 6.5

Preset Function (Compare with:) ..................................... 101

6.5.1 Preset function ..................................................................... 101 6.5.2 Using “?” and “!” in the preset data ...................................... 101 6.6

Additional Information Function ...................................... 102

6.6.1 Decode match count add function ....................................... 102 6.6.2 Scan count add function (valid only if using the decoding count add function) ........... 102 6.6.3 Code type add function ........................................................ 103 6.6.4 Label orientation add function .............................................. 103 6.6.5 Symbology ID add function .................................................. 104 6.6.6 PMI add function .................................................................. 104 6.6.7 Order of the additional information ...................................... 106 6.7

Max. Code Length (Designated Digit ) Output Function ................................................................. 107

Page 16

Chapter 6

6.1

Functions for Reading Operation

Read Operation This section describes the scanning methods of the BL-600 Series.

6.1.1 Scanning method There are two methods to trigger the BL-600 Series to read bar codes: the “Level signal” method and the “One-shot signal” method. Select an appropriate method according to the application. Typically, the “Level signal” method is used. The following examples for these two methods use the “6.2.1 Single label read mode”. ➮ See page 88.

Level signal trigger When the trigger input turns on, the BL-600 Series starts laser emission to read the bar codes. The laser turns off after the number of the bar code reading reaches the specified decoding match count. ➮ See page 43. The BL-600 Series then sends the read data. Reference 1: The BL-600 Series can read up to 4 types of bar codes without changing settings. ➮ See page 49. Reference 2: Pressing the TEST switch lightly (for less than 2 seconds) serves as a trigger input (The laser turns on once.). ➮ See page 8. ■ Timing diagram <Succeed to read> Trigger input

6

<Fail to read> *1

Bar code Laser beams

*2

Communication time

*3

OK/NG output

OK/NG *4

NG

*5

*1 Set trigger input so that it stays on long enough for the laser beam to cover the entire bar code. *2 The BL-600 Series emits a laser after the trigger input exceeds the preset input time. ➮ See the following note. Note: The BL-600 Series has a built-in AGC (auto gain control) circuit. It requires a maximum of 3 scans (6 ms) to adjust the gain. Therefore, the BL-600 Series requires a maximum of 6 ms after the laser beam turns on before it begins to read the data. *3 The communication time can be obtained from the following expression: Data bits + (1: If parity is used) + Start/stop bit Baud rate

(Code length of data to be X sent + Header/number of characters in delimiter)

*4 The length of time that the OK/NG output is on can be changed to any value between the range of 10 ms to 2.55 s. ➮ See page 53. *5 The OK/NG output turns on 5 ms after the bar code is read. If the bar code cannot be read, the NG output is delayed by 5 ms plus the specified input time.

86

Page 17

Chapter 6

Functions for Reading Operation

Note: 5 seconds after the power switch turns on or an UNLOCK command ( ➮ See page 116.) is sent, the unit will not start reading a bar code by turning on the trigger input.

One-shot signal trigger The BL-600 Series detects when the trigger input turns on and starts reading bar codes for the preset “One shot input time”. ➮ See page 44. The laser turns off after the number of the bar code reading reaches the specified decoding match count. ➮ See page 43. The BL-600 Series then sends the read data. The rest of the operation is the same as that for the “Level signal” method. Use the one-shot signal trigger when the one shot input time is extremely short or to fix the scanning time. Reference 1: The BL-600 can read up to 4 types of bar codes without changing the bar code type setting. ➮ See page 49. Reference 2: Pressing the TEST switch lightly (for less than 2 seconds) serves as a trigger input (The laser turns on once.). ➮ See page 8. ■ Timing diagram Trigger input

<Succeed to read> *1

<Fail to read>

Bar code Preset input time

Preset input time

Laser beams Communication time OK/NG output

OK/NG

6

NG

*1 After the trigger input exceeds the preset input times, the laser begins to emit. Trigger input minimum ON time: 5 ms (when the trigger input value is 2 ms) 15 ms (when the trigger input value is 10 ms) Note: The BL-600 has a built-in AGC (auto gain control) circuit. It requires a maximum of 3 scans (6 ms) to adjust gain. The BL-600 generates a maximum of 6 ms delay until starting to read the data after the laser beam turns ON.

87

Page 18

Chapter 6

6.2

Functions for Reading Operation

Read Modes The BL-600 provides 4 types of read modes.

6.2.1 Single label read mode The single label read mode allows the BL-600 Series to read only one bar code during one trigger input signal. ■ Data output timing The BL-600 Series offers the following two data output modes to send data and output OK/NG signals. Select an appropriate mode according to the application. Typically, “After Read” is selected. ● After Read ➮ See page 42. The BL-600 Series sends read data and outputs an OK/NG signal after a successful read. This is the operation described in “6.1.1 Scanning methods” on page 86 and 87. ● At trigger input ➮ See page 42. The BL-600 Series sends read data and outputs an OK/NG signal at the following timings. •

For a “Level signal” trigger ➮ See page 86.: When the trigger input turns off

•

For a “One-shot” trigger ➮ See page 87.: After the preset input time has passed

6

<Fail to read>

<Succeed to read> Trigger input Bar code Laser beams Communication time OK/NG output

*

88

OK/NG

NG

The timing diagram above shows the case for a “Level signal” trigger.

Page 19

Chapter 6

Functions for Reading Operation

6.2.2 Multi-label read mode 1 (Multi 1) Multi-label read mode 1 allows the BL-600 Series to continuously read all of the several bar codes printed on one label during one trigger input signal. The BL-600 Series outputs the read data every time one bar code is read.

■ Timing diagram

<Succeed to read>

<Fail to read>

Trigger input Repeat reading time Bar code Laser beams Communication time OK/NG output

*

*

OK

OK

OK

OK

NG

6

The BL-600 Series continuously reads bar codes in the following periods. •

For a “Level signal” trigger ➮ See page 86.: During the trigger input signal

•

For a “One-shot” trigger ➮ See page 87.: During the preset input time

It is necessary to set the “Repeat-reading time” (➮ See page 42.) to prevent the BL600 Series from reading the same bar code twice. Set the “Repeat-reading time” longer than the time it takes for the read bar code to go out of the field of the laser beam (100 ms to 25.5 s).

Note: The same type of bar code cannot be read during the specified repeatreading time. Different types of bar codes can be read continuously during the period. *

The OK output turns on every time the BL-600 Series reads a bar code. (Comparison to the preset data is not performed.) The NG output turns on after the trigger input turns off if the BL-600 Series fails to read any of the bar codes.

89

Page 20

Chapter 6

Functions for Reading Operation

6.2.3 Multi-label read mode 2 (Multi 2) Multi-label read mode 1 allows the BL-600 Series to continuously read all of the several bar codes printed on one label during one trigger input signal. *

The number of readable bar codes varies depending on the capacity of the transmission buffer of the BL-600 Series. ➮ See page 112.

In multi-label read mode 2, all the read data is sent at one time after the trigger input turns off. ■ Timing diagram <Succeed to read> Trigger input

<Fail to read>

Repeat reading time

Bar code

1 2 3 4 5 Laser beams Communication time 12345 OK

OK/NG output

*

6

*

NG

The BL-600 Series continuously reads bar codes in the following periods. •

For a “Level signal” trigger ➮ See page 86.: During the trigger input signal

•

For a “One-shot” trigger ➮ See page 87.: During the preset input time has passed

It is necessary to set the “Repeat-reading time” (➮ See page 42.) to prevent the BL600 Series from reading the same bar code twice. Set the “Repeat-reading time” longer than the time it takes for the read bar code to go out of the field of the laser beam (100 ms to 25.5 s).

Note: The same type of bar code cannot be read during the specified repeatreading time. Different types of bar codes can be read continuously during the period. *

The OK signal turns on if the BL-600 Series reads at least one bar code. (Comparison to the preset data is not performed.) The NG signal turns on if the BL-600 Series fails to read any of the bar codes.

■ Data format The read data is sent to the personal computer in the following format. Header

1st data

,

2nd data

,

3rd data

4th data

,

•••••••

Delimiter

*

Each data packet is separated by a comma (, : 2CH) (intermediate delimiter).

*

The unit sends as many data packets the number of bar codes read.

*

The number of bar codes varies depending on the capacity of the transmission buffer of the BL-600 Series. ➮ See page 112.

➮ See page 113 for “header string” and “delimiter”.

90

,