Chapter 5 Installation This chapter describes the procedure and cautions for the installation of the BL-600 Series and special power supply unit.
5.1
Installation of the BL-600 Series ........................................ 72
5.1.1 5.1.2 5.1.3 5.1.4 5.1.5
Situations to check for before installing the BL-600 Series ... 72 Mounting angle and distance ................................................. 74 Mounting the BL-600/601/600HA/601HA .............................. 75 Mounting the BL-650HA/651HA ............................................ 77 Mounting the BL-600 Series without the mounting bracket ... 79
5.2
Installation of the Special Power Supply Unit ................... 81
5.2.1 In-panel installation ................................................................ 81 5.2.2 Installing the BL-U1 ............................................................... 81 5.2.3 Installing the BL-U2 and N-42 ................................................ 83
Page 2
Chapter 5
5.1
Installation
Installation of the BL-600 Series This section describes situations to check for before installing the BL-600 Series, and the installation procedure.
5.1.1 Situations to check for before installing the BL-600 Series Check the following points before installing the BL-600 Series. Avoid extraneous light from entering the transmitter/receiver of the BL-600 Series. Otherwise, the reading may fail or be unreliable. Change the position of the sensor.
Cut off the extraneous light.
Remedy
Photoelectric sensor
;; ;; ;;
; ; ; ;
If something interrupts the emitted or reflected laser beam, the reading may be unreliable.
5
Bar code
Light-shielding object
Remedy
Reflected beam
Change the position of the lightshielding object to ensure passage of the laser beam.
If the laser beam reflects the bar code at a right angle (specular reflection), the reading may fail or be unreliable.
Emitted laser beam
Remedy
15°
Reflected laser beam Be sure to apply the laser beam at some angle.
*
72
Since the BL-650HA/651HA emits a laser beam at an angle of 17°, tilting the unit is unnecessary.
Page 3
Chapter 5
Installation
If a strong reflected light enters the receiver of the BL-600 Series, the reading may fail or be unreliable.
Remedy
;; ;;;; ;;
Cover the metal surface with black tape to avoid reflection.
Metal surface
If reflected light enters the receiver of another unit, the reading may be unreliable, because of mutual interference. Place a lightshielding plate.
Bar code
Remedy
5 Keep a distance between the units.
BL-600 Series
If two or more bar code labels enter the laser beam at the same time, the BL-600 cannot be set to read a specific bar code. Keep a distance between the bar codes. Bar code Remedy
Decrease the scanning width.
➮
See page 67 to change the scanning width.
*
When “Multi-label read mode 3” is specified, the BL-600 Series can simultaneously read up to 4 bar codes in the field of the laser beam.
73
Page 4
Chapter 5
Installation
5.1.2 Mounting angle and distance The BL-600 Series must be installed so that the laser beam is applied at an angle of approximately 15° with reference to a line perpendicular to the target. This means that the BL-600/601/600HA/601HA must be tilted at an angle of 15°. Since the BL-650HA/651HA emits a laser beam at an angle of 17°, tilting the unit is unnecessary. Refer to the read range and angle characteristics on pages 148 to 150 for the appropriate mounting angle and distance for the BL-600 Series. Normally, the BL-600 Series provides the best reading stability when mounted at the following angle and distance. BL-600/601/600HA/601HA Reading distance
BL-650HA/651HA Reading distance
15°
17°
Reading distance BL-600/601: 120 mm BL-600HA/601HA: 90 mm
Reading distance BL-650HA/651HA: 65 mm
5 * * *
The supplied mounting bracket facilitates the angle setting. (➮ See pages 75 to 78.) The reading rate check mode (➮ See pages 94 to 96.) ensures an optimal reading position. The laser beam application angle for the BL-650HA/651HA is 17° ±3° with reference to a line perpendicular to the rear surface of the unit.
Note 1: Do not mount the BL-600 Series so that the laser beam is applied to bar codes at a right angle (±10°). Otherwise, the specular reflections may cause unstable reading or reading errors. (➮ See page 151.) BL-600/601/600HA/601HA
BL-650HA/651HA 17°
Within ±10° Within ±10° Incorrect
Incorrect
Note 2: The reading distance and angle may vary depending on the narrow bar width, size, and printing quality of bar codes. Be sure to test the BL-600 Series’ ability to read the actual bar codes using “Reading rate check mode” on pages 94 to 96.
74
Page 5
Chapter 5
Installation
5.1.3 Mounting the BL-600/601/600HA/601HA The following is the procedure for mounting the BL-600/601/600HA/601HA with the supplied mounting bracket. To mount the BL-600 Series without the mounting bracket, refer to “Mounting the BL-600 Series without the mounting bracket” on pages 79 and 80. 1. Check the surroundings of the mounting position. Check the surroundings according to “Situations to check for before installing the BL-600 Series” on pages 72 and 73. 2. Attach the BL-600 Series to the mounting bracket. ➮ Refer to page 155 for the dimensions of the mounting bracket.
When bracket A is used
When bracket B is used
Supplied mounting screw (M3)
Laser beam
Mounting bracket B
Laser beam Supplied mounting screw (M3)
Mounting bracket A
3. Temporarily fix the mounting bracket. The angle of the laser beam application is 15° when the BL-600 Series is secured to the mounting bracket as shown below. ➮ See “5.1.2 Mounting angle and distance” on page 74 for the mounting distance.
When mounting bracket A is used:
When mounting bracket B is used:
Bar code
Bar code
BL-600 Series
BL-600 Series 15°
15° Perpendicular line
Mounting bracket
Bar code
Mounting bracket
Mounting bracket
Perpendicular line
Bar code
Mounting bracket
75
5
Page 6
Chapter 5
Installation 4. Check the reliability of the bar code reading using the Test mode. Check the reliability of the bar code reading using “Reading rate check mode”. ➮ See pages 94 to 96.
5. Check the surroundings and adjust the mounting distance and angle. If the bar code reading is unreliable, check/adjust the position again by referring to “5.1.1 Situations to check for before installing the BL-600 Series” on pages 72 and 73 and “5.1.2 Mounting angle and distance” on page 74. 6. Fasten the mounting bracket. * *
Mounting screws (M4) are not included. To suppress the noise conveyed through the mounting bracket, be sure to use insulating spacers.
When bracket A is used
Mounting screw (M4) Washer Insulating spacer
5
76
When bracket B is used Mounting screw (M4) Washer Insulating spacer
Page 7
Chapter 5
Installation
5.1.4 Mounting the BL-650HA/651HA The following is the procedure for mounting the BL-650HA/651HA with the supplied mounting bracket. To mount the BL-600 Series without the mounting bracket, refer to “Mounting the BL-600 Series without the mounting bracket” on page 79. 1. Check the surroundings of the mounting position. Check the surroundings according to “5.1.1 Situations to check for before installing the BL-600 Series” on pages 72 and 73. 2. Attach the BL-600 Series to the mounting bracket. *
The mounting bracket for the BL-650HA/651HA allows two mounting orientations. Choose the appropriate orientation according to the application.
➮ Refer to page 155 for the dimensions of the mounting bracket.
Laser beam
Laser beam
Mounting bracket
Mounting bracket
Supplied mounting screw (M3)
Supplied mounting screw (M3)
3. Temporarily fix the mounting bracket. Since the BL-650HA/651HA emits a laser beam at an angle of 17°, install the unit parallel to the surface of the bar code as shown below. ➮ See “5.1.2 Mounting angle and distance” on page 74 for the mounting distance.
*
The laser beam application angle for the BL-650HA/651HA is 17° ±3° with reference to a line perpendicular to the rear surface of the unit. BL-650HA/651HA
BL-650HA/651HA Bar code
Bar code
Parallel Parallel Mounting bracket
Mounting bracket
Bar code
Bar code
BL-650HA/651HA BL-650HA/651HA
Mounting bracket
Mounting bracket
77
5
Page 8
Chapter 5
Installation 4. Check the reliability of the bar code reading using the Test mode. Check the reliability of the bar code reading using “6.4.1 Reading rate check mode”. ➮ See pages 94 to 96. 5. Check the surroundings and adjust the mounting distance and angle. If the bar code reading is unreliable, check/adjust the position again by referring to “5.1.1 Situations to check for before installing the BL-600 Series” on pages 72 and 73 and “5.1.2 Mounting angle and distance” on page 74. 6. Fasten the mounting bracket. * *
Mounting screws (M4) are not included. To suppress the noise conveyed through the mounting bracket, be sure to use insulating spacers.
Mounting screw (M4) Washer Insulating spacer
5
78
Page 9
Chapter 5
Installation
5.1.5 Mounting the BL-600 Series without the mounting bracket 1. Check the surroundings of the mounting position. Check the surroundings according to “5.1.1 Situations to check for before installing the BL-600 Series” on pages 72 and 73. 2. Temporarily mount the BL-600 Series in position. The BL-600 Series must be installed so that laser beam is applied at an angle of approximately 15° with reference to a line perpendicular to the target. This means that the BL-600/601/600HA/601HA must be titled at an angle of 15°. Since the BL-650HA/651HA emits a laser beam at an angle of 17°, tilting the unit is unnecessary. Mount the BL-600 Series in the following orientation according to the laser beam orientation to be used. BL-600/601/600HA/601HA
BL-650HA/651HA
5
➮ See “5.1.2 Mounting angle and distance” on page 74 for the mounting distance.
*
The laser beam application angle for the BL-650HA/651HA is 17° ±3° with reference to a line perpendicular to the rear surface of the unit.
3. Check the reliability of the bar code reading using the Test mode. Check the reliability of the bar code reading using “Reading rate check mode”. ➮ See pages 94 to 96.
4. Check the surroundings and adjust the mounting distance and angle. If the bar code reading is unreliable, check/adjust the position again by referring to “5.1.1 Situations to check for before installing the BL-600 Series” on pages 72 and 73 and “5.1.2 Mounting angle and distance” on page 74.
79
Page 10
Chapter 5
Installation 5. Fasten the BL-600 Series. Fasten the BL-600 Series in the mounting position with M3 screws. * The M3 screws are not included. Select the M3 screws after checking the panel thickness and other factors of the mounting position. (The mounting hole for the BL-600 Series is 4 mm deep.) BL-600/601/600HA/601HA
BL-650HA/651HA
Mounting hole
Mounting hole
Mounting screw (M3)
5
80
Mounting screw (M3)