Page 21

Chapter 6

Functions for Reading Operation

6.2.4 Multi-label read mode 3 (Multi 3) •

Multi-label read mode 3 allows the BL-600 Series to continuously read one of each of the 4 bar code types, “Code 1” to “Code 4”, as specified in the [[Code setup]] screen of the setup software (➮ See page 49.) during one trigger input signal. *

•

If three types are specified in the [[Code setup]] screen, the BL-600 Series reads three bar codes. If two types are specified, it reads two bar codes.

Even if several bar codes (4 max.) exist in the field of the laser beam, the BL600 Series can simultaneously read all the bar codes, provided the data of all the bar codes is different.

The BL-600 Series sends all the read data at one time in the order of “Code 1” to “Code 4” after the trigger input turns off. ■ Timing diagram <Succeed to read>

<Fail to read>

Trigger input Bar Code

Code 1 Code 2 Code 3 Code 4

Laser beams

*

Code 4

Code 3

OK

OK/NG output

*

Code 2

Code 1

Communication time

NG

The BL-600 Series continuously reads bar codes in the following periods. •

For a “Level signal” trigger ➮ See page 86.: During the trigger input signal

•

For a “One-shot” trigger ➮ See page 87.: During the preset input time

6

The OK signal turns on if the BL-600 Series reads all the bar codes specified for “Code 1” to “Code 4”.(Comparison to the preset data is not performed.) The NG output turns on if the BL-600 Series fails to read at least one bar code.

■ Data format The read data is sent to the personal computer in the following format. Data read

Header from Code 1

Data read

Data read

Data read

2

3

4

, from Code , from Code , from Code Delimiter

*

Each data packet is separated by a comma (, : 2CH) (intermediate delimiter).

*

If the reading fails for any one of the Codes 1 to 4, or the corresponding bar code does not exist, an “ERROR” (➮ See page 112 for the reading error codes.) is sent instead of the read data.

➮

See page 113 for “header string” and “delimiter”.

91

Page 22

Chapter 6

Functions for Reading Operation Example Suppose that the following codes are specified:

•

“Code” setting

Type of bar code

No. of digits

Code 1

CODE39

10 digits

Code 2

EAN/UPC

13 digits

Code 3

–

–

Code 4

CODE39

8 digits

When the unit successfully reads all 3 types of codes: Header

•

ABCDE12345

ERROR

Delimiter

, 4901234567894 ,

KEYENCE1

Delimiter

When the unit fails to read Code 1 (CODE39, 10 digits) and Code 4 (CODE39, 8 digits) Header

*

KEYENCE1

When the unit fails to read Code 1 (CODE39, 10 digits) Header

•

, 4901234567894 ,

ERROR

, 4901234567894 ,

ERROR

Delimiter

When the same type of data having the same digits is specified to all Codes 1 to 4, the unit sends the data in the reading order.

Example Suppose that the following codes are specified:

6

“Code” setting

Type of bar code

No. of digits

Code 1

CODE39

7 digits

Code 2

CODE39

7 digits

Code 3

CODE39

7 digits

Code 4

CODE39

7 digits

Header

ABCD123

,

XYZ3333

,

1234567

,

KEYENCE

,

Delimiter

Note: The unit cannot read the bar code having the same content twice while trigger input turns on once.

92

Page 23

Chapter 6

Label Orientation Mode You can specify the orientation of the bar code labels to be read. The label orientation mode allows the BL-600 Series to only read the bar codes in the specified orientation if the bar code labels are moving in both the forward and reverse directions. Normally, the unit can read bar codes regardless of the orientation. ➮ See page 53.

9000000

9000000

4

Forward orientation

4

6.3

Functions for Reading Operation

Reverse orientation

■ Timing diagram

<Specified orientation>

<Non-specified orientation>

Trigger input Bar code Laser beams

6

Communication time OK/NG output

OK/NG

NG

*

The timing diagram above shows the case for the “single label read mode”.

•

A reading error is issued if the BL-600 Series reads a bar code label moving in an orientation that is not specified.

•

This mode can be used with the desired multi-label read mode. However, the BL-600 Series does not read bar codes moving in an orientation that is not specified.

•

You can specify the orientation individually for Codes 1 to 4, such as specifying “forward orientation” for Code 1, and “reverse orientation” for Code 2.

93

Page 24

Chapter 6

6.4

Functions for Reading Operation

Test Mode Test mode can be used for the bar code reading test. The BL-600 Series offers three types of test mode. Note: The BL-600 Series continues laser emission during test mode. This can shorten the service life of the laser. Only select test mode when you need to perform a reading test.

6.4.1 Reading rate check mode The reading rate check mode is used to measure how many times the BL-600 Series can decode the scanned data while scanning a bar code 100 times. This mode is useful for the following cases: ● Adjusting the mounting distance and angle Adjust the mounting distance and angle so that the highest reading rate is obtained. ● Verifying the reading reliability of the bar code to be used A high reading rate shows that the printing quality of the bar code is high. Note: The reading rate check should only be performed for a stationary bar code. ■ Starting method There are four methods to start the reading rate check mode. Select one of the following for your convenience.

6

• • •

Press the TEST switch of the BL-600 Series. Use the [[Monitor]] screen of the setup software. ➮ See page 62. Use the bar code display interface BL-V35E. ➮ See the BL-V35E User’s Manual.

■ Operation The following instruction uses the TEST switch to start/quit the reading rate check. All other operations are the same for the other starting methods. 1. Set the mounting distance and angle of the BL-600 Series. ➮ See page 75. BL-600/601/600HA/601HA Reading distance

BL-650HA/651HA Reading distance

15° 17°

Reading distance BL-600/601: 120 mm BL-600HA/601HA: 90 mm

Reading distance BL-650HA/651HA: 65 mm

Note : Do not mount the BL-600 Series so that the laser beam is applied to bar codes at a right angle (±10°). Otherwise, the specular reflections may cause unstable reading or reading errors. ➮ See page 151. BL-600/601/600HA/601HA

BL-650HA/651HA

17° Within ±10° Within ±10°

94

Page 25

Chapter 6

Functions for Reading Operation

2. Start the test mode. 1) Press the TEST switch for 3 seconds. 2) When one STABILITY LED illuminates, release the TEST switch. The BL-600 Series continues laser emission. Press the TEST switch for 3 seconds. LASER ON

E

S

T

OK/NG T

TIMING

O T IM K /N G IN G

TEST

LA

SE

RO

N

BL-600

WARNING

Do not look directly at the laser beam. This may result in serious eye injury. The laser beam is not harmful to the skin; however, do not intentionally direct the laser beam at the human body. 3. Read the bar code. The BL-600 Series displays the STABILITY LEDs as shown in the following table depending on the “Reading rate”, which shows the number of times it can decode the scanned data while scanning a bar code 100 times. While checking the display, adjust the mounting distance and angle so that the reading rate reaches its highest level. *

ON/NG LED turns ON but OK/NG output does not turn ON. Reading rate

STABILITY LED

OK/NG LED

81 to 100 %

5 LEDs ON

Green

61 to 80 %

4 LEDs ON

Green

41 to 60 %

3 LEDs ON

Green

21 to 40 %

2 LEDs ON

Green

1 to 20 %

1 LED ON

Green

0%

–

Red

Note1: The higher the reading rate indicated, the more accurately and reliably the bar code is read. However, this does not mean that the reading is only possible with a reading rate of 100%. For example, if the reading rate is displayed as 20%, 20 reads were acceptable during the 100 scans. The read operation is not affected if the scanning time for the bar code is set long enough. Note2: If a raster-scanning model (BL-601/601HA/651HA) is used for a bar code with a short height, some laser beams will not be applied to the bar code, resulting in a low reading rate. For example, if only 4 out of the 8 laser beams of the BL-600 Series can scan the bar code, the highest reading rate obtained will be 50%. However, this problem can also be solved if the scanning time for the bar code is set long enough.

95

6

Page 26

Chapter 6

Functions for Reading Operation 4. The BL-600 Series sends data. In test mode, the BL-600 Series sends the data in the following format every 100 scans. Partition mark Readout data

:

m m = Reading rate (1 to 100) (Zero-suppressed)

*

You can set the BL-600 Series so that it will not send data while in the test mode. ➮ See page 54.

*

To check the reading rate on a PC screen, connect the BL-600 Series to a PC and use the [[Monitor]] screen of the setup software. ➮ See page 62.

5. Quit the test mode. Press the TEST switch again to quit the test mode. The STABILITY LED turns off.

6

T

E

S

T

Press once.

O T IM K /N G IN G

LA SE RO N

Note 1: If the additional information function (➮ See pages 102 to 106.) is used while in the test mode, the BL-600 Series adds the specified data in the same manner as in normal operation. However, only if the “Reading rate check mode” is selected, will the “Decoding count” and “Scan count” data not be added. Note 2: If a PLC link is used, the read data, reading rate, and decoding count are not written while the test mode is active.

96

Page 27

Chapter 6

Functions for Reading Operation

6.4.2 Tact check mode The tact check mode is used to count how many scans the BL-600 Series can accurately read (decode) while reading a moving bar code. This mode is useful for the following case: ● Testing the line speed that can be expected before actually implementing the BL-600 Series on the line A large decoding number shows that the BL-600 Series can reliably read the bar code (capable for the line speed). Note: The tact check should be performed on a moving bar code. ■ Starting method There are four methods to start the reading rate check mode. Select one of the following for your convenience. • • •

Press the TEST switch of the BL-600 Series. Use the [[Monitor]] screen of the setup software. ➮ See page 62. Use the bar code display interface BL-V35E. ➮ See the BL-V35E User’s Manual.

■ Operation The following instruction uses the TEST switch to start/quit the reading rate check. All other operations are the same for the other starting methods. 1. Install the BL-600 Series. Install the BL-600 Series according to “Chapter 5, Installation” on page 72.

6

2. Start the test mode. 1) Press the TEST switch for 5 seconds. 2) When two STABILITY LED illuminates, release the TEST switch. The BL-600 Series continues laser emission. Press the TEST switch for 5 seconds. LASER ON

G

/N

IN

O

K

TIMING

T IM

G

T

E

S

T

OK/NG

TEST

LA SE RO N

BL-600

WARNING

Do not look directly at the laser beam. This may result in serious eye injury. The laser beam is not harmful to the skin; however, do not intentionally direct the laser beam at the human body.

97

Page 28

Chapter 6

Functions for Reading Operation 3. Read the bar codes moving on the line. Depending on the decoding count, the BL-600 Series displays the STABILITY LEDs as shown in the following table 0.2 seconds after the bar code has passed the field of the laser beam. By checking the display, you can notice the reliability that the BL-600 Series ensures during the readout (how capable it is for the line speed). Decoding count STABILITY LED 100 or more

5 LEDs ON

50 to 99

4 LEDs ON

10 to 49

3 LEDs ON

5 to 9

2 LEDs ON

1 to 4

1 LED ON

OK/NG LED Green (The readout count equals or exceeds the specified decoding match count.) ➮ See page 43. Red (The readout count is below the specified decoding match count.) ➮ See page 43.

*

ON/NG LED turns ON but OK/NG output does not turn ON.

*

The BL-600 Series continues to read data while bar codes are in the field of the laser beam. Therefore, the STABILITY LEDs do not illuminate.

*

If reading bar codes with the same data continuously within 0.2 seconds, the BL-600 Series cannot differentiate between the data and continues to scan and add to the decoding count without displaying the STABILITY LEDs. If the BL-600 Series reads different bar codes within 0.2 seconds of each other, it displays the STABILITY LEDs to show the decoding count.

4. The BL-600 Series sends data. The BL-600 Series sends the data to the PC in the following format every time the STABILITY LEDs illuminate. Partition mark

6

Readout data

:

m m = Decoding count (1 to 9999) (Zero-suppressed)

*

A value greater than 9999 cannot be added.

*

You can set the BL-600 Series so that it will not send data while in the test mode. ➮ See page 54.

Note: It should be judged that the BL-600 Series is capable for the line speed if the decoding count is always more than 5 to 10. If the decoding count is only 1 or 2, you need to perform a reading rate check (➮ See pages 94 to 96.) and change the position of the bar code reader to obtain a higher reading rate.

98

Page 29

Chapter 6 *

Functions for Reading Operation

To check the reading rate on a PC screen, connect the BL-600 Series to a PC and use the [[Monitor]] screen of the setup software. ➮ See page 62.

5. Quit the test mode. Press the TEST switch again to quit the test mode. The STABILITY LED turns off. Press once.

TE

ST

O T IM K /N G IN G

LA SE RO N

6 6.4.3 Online test mode The online test mode allows the BL-600 Series to display the reading reliability in real time during normal reading operation. ■ Operation 1. Set the online test mode. 1) Send the “#TEST1” command to the BL-600 Series using the [[Monitor]] screen of the setup software. ➮ See page 62. 2) The setting is completed when a response to the sent command “OK” is returned from the BL-600 Series. 2. Read bar codes with the BL-600 Series. After the trigger input turns off, the BL-600 Series sends the read data and displays the reading reliability with the STABILITY LEDs. 3. Quit the online test mode. 1) Send the “#QUIT” command to the BL-600 Series using the [[Monitor]] screen of the setup software. ➮ See page 62. 2) The mode is ended when a response to the sent command “OK” is returned from the BL-600 Series. Note: The command setting is only effective if the BL-600 Series is turned on. The setting will be reset when the power is turned off.

99

Page 30

Chapter 6

Functions for Reading Operation Reference: To save the online test mode setting in the BL-600 Series, set the following using the setup software. • [[Main]]

→ “Additional information”

→ Select “Decoding count”. ➮ See page 43.

→ Select “Scan count”. ➮ See page 43.

• [[Utilities]] → “Stability LED”

→ Select “Use stability LED”. ➮ See page 53.

■ STABILITY LED display The STABILITY LEDs illuminate as shown in the table, indicating how many times the BL-600 Series can correctly read (decode) the data of the moving bar codes. Decoding count

STABILITY LED

100 or more

5 LEDs ON

50 to 99

4 LEDs ON

10 to 49

3 LEDs ON

5 to 9

2 LEDs ON

1 to 4

1 LED ON

0

–

■ Data format The BL-600 Series appends the number of scans (scan count) and the number of correctly read bar codes (decoding count) while one trigger input turns on.

6

*

The scan count includes the cases where a bar code does not exist in the field of the laser beam. Partition mark Readout data

:

m

/ s m = Decoding count (1 to 9999) (Zero-suppressed) s = Scan count (1 to 9999) (Zero-suppressed)

100