Page 41

User Interface

2

EMS Driver An Expanded Memory Manager is included with the T2090 Programmer’s Software Kit and conforms to LIM EMS 4.0. This driver places all RAM above 640K into Expanded Memory available to applications through INT 67. In the T2090, with a 2MB RAM chip installed, the amount of EMS RAM available is: 2048K - 64K(BIOS shadow) - 640K(DOS area) = 1344K To install the driver, the developer needs to place the driver file, VG330EMS.SYS on the Read/Write drive of the T2090 (drive C). This is usually done at the root directory. Then the line shown below must be added to the C:\CONFIG.SYS file: DEVICE=C:\VG330EMS.SYS

It is important within this device installation line to include the full drive and path because during system boot, the C drive is not part of the initial path; only the A drive is part of the assumed path.

RAMDRIVE Driver A RAMDRIVE system driver is included with the T2090 to allow the developer to use RAM as a virtual drive. This driver will, by default, use Expanded Memory if available. If not, then RAM will be taken from the lower 640K DOS area. To install the driver, the developer needs to place the driver file, MEMEMS.SYS on the Read/Write drive of the T2090 (C:). This is usually done at the root directory. Then the following line must be added to the C:\CONFIG.SYS file: DEVICE=C:\MEMEMS.SYS [disk size [sector size [root entries]]] where: disk size is the size of the desired ramdisk in kbytes (min. 16, default = 64)

sector size is the desired sector size (128, 256, 512 or 1024) in bytes (default = 512)

root entries is the number of root directory entries from 2 to 1024 (default = 64)

It is important within this device installation line to include the full drive and path because during system boot, the C drive is not part of the initial path; only the A drive is part of the assumed path.

2-9

Page 42

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Docking Indicators The unit has visual feedback on the state of being placed in the EZ Dock Docking System. When the unit is initially placed in the docking system, it beeps and the LED turns RED. After five seconds, the status of the charging cycle is checked. If the system is actively charging, it blinks red off/on with a duty cycle of four seconds (two seconds off, two seconds on) for a minimum of 15 minutes. Once the battery is fully charged, the LED turns green and is on in a steady state. When the unit is removed from the docking system, it beeps and turns off the LED. The unit can be removed at any point during the charging cycle. This indicator turns red, then green, within five seconds and remains green if no battery is installed.

Battery Monitor Applications can monitor the state of the battery by using the software Int 15h discussed in Chapter 7. A low battery condition occurs when the battery voltage is 2.2v or less. If a very low battery condition occurs (2.0 v or less), the unit enters SUSPEND state (see Chapter 6 for handling very low battery conditions). Also, under cold boot conditions, if a low battery is detected, the unit will power off without booting.

Keyboard Mode Indicator An alpha/numeric keyboard mode indicator can be called by applications or displayed on the screen at all times. Displaying the indicator is selectable as an option under the Setup routine (discussed later in this chapter) or is callable by applications through the Int 10h mechanism. The indicator is a 16 x 8 pixel area mapped out to read either “123” for numeric mode or “ABC” for alpha mode. The default condition is numeric.

×

Pressing the key toggles between the two modes and changes the indicator on the screen. Developers should note that if the keyboard mode indicator is displayed, the small area of the screen being used by the indicator is protected and is not available for displaying other characters. ( See Chapter 7.)

2-10

Page 43

User Interface

2

System Defaults and Initial Conditions Power States There are five power states: •

ON

•

DOZE

•

SLEEP

•

SUSPEND

•

OFF

L

SUSPEND and OFF are mutually exclusive and can be set by the developer or the user. The key can be used at any time in the ON, DOZE or SLEEP state to enter either SUSPEND or OFF, depending on which is selected, and pressing the key when in SUSPEND or OFF enters the ON state.

L

The figure on the next page is a state diagram for the automatic power saving functions. Automatic states are reached sequentially on a decreasing power consumption curve from the first state, ON (CPU at full speed, all systems powered up). The second state is DOZE (CPU slows to 25% of normal speed). The third state is SLEEP, (backlight shuts off). The last state is SUSPEND/OFF (everything powered down, except RTC; if SUSPEND is set, power is retained for RAM). Note: If any one of the powered-down states time parameters are set to zero, it has the effect of canceling that particular state as an option and all the other states below it. That is, if SLEEP is set to zero, the unit will never get to the SUSPEND state, the backlight will never shut off and there won’t be any auto timeout, and if DOZE is set to 0, NO power management occurs. Activities are defined as keypress, disk access, serial communications and the default video access. DOZE times can be set in 1/8 second increments, up to 2 seconds, then in one second increments up to 14 seconds. SLEEP and SUSPEND/OFF can be set from 0 to 15 minutes. Current defaults from the factory are: To enter DOZE from ON:

1/2 second

To enter SLEEP from DOZE:

1 minute

To enter SUSPEND/OFF from SLEEP:

1 minute

2-11

Page 44

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

PREVIOUS STATE(S)

ENTRY CAUSE(S)

N/A

HARD RESET KEY

SUSPEND/ OFF DOZE OR SLEEP ON

DOZE

SLEEP ON, DOZE, SLEEP

L

CURRENT STATE

EXIT CAUSE(S)

NEXT STATE DOZE

ON

NO ACTIVITY KEY

DOZE

ACTIVITY

L

SUSPEND/ OFF

ACTIVITY NO ACTIVITY

NO ACTIVITY

NO ACTIVITY KEY

L

L KEY SLEEP

SUSPEND/ OFF

ON

ACTIVITY

SUSPEND/ OFF ON

L KEY L KEY

SUSPEND/ OFF ON

RTC ALARM UNIT DOCKED

ON ON

ACTIVITY = one of the keys was pressed, disk was accessed, serial communications were attempted. NO ACTIVITY = none of above occurred within a preset timeframe. Timeouts are set through Setup as discussed later in this chapter.

2-12

Page 45

User Interface

2

Starting Setup Mode

L

The setup mode is entered when the user presses the F1 (left key under the display) key after pressing the key or by typing FWTSETUP at the DOS prompt. The Enter Password screen is then displayed. Note: Examples of screens illustrated in the remainder of this chapter have rows and columns numbered to show actual placement on the display. All of the data entry screens have the ‘BS’ destructive backspace key available. Except for ‘BS’, keys not specified as having any action are ignored.

Enter Password Screen The keys and actions for the Enter Password screen are as follows: •

0 - 9, A - Z, the dash mark (-), the space key, and the period (.) are all valid for the password

•

F3 “ACCEPT” or ENTER keys accepts the value entered for verification. The default factory password is “123.” Setup Utility Version 1.5 123

Enter Password: _

F1

F2

ACCEPT F3

As the password is entered, an asterisk is displayed for each character entered. If the user fails to enter the correct password after three tries, Setup access is denied. If a correct password is entered, Setup access is allowed and the Setup Main Menu is displayed. Note: Password data is stored in the C: drive in a hidden file, IMP.DAT. If this file is corrupted or deleted, it will be re-written with the default password (“123”) on the next boot.

2-13

Page 46

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Setup Main Menu The Setup main menu screen has four menu items and three valid function keys. The keys and actions for the Setup main menu are as follows: •

1 calls up the Power Management screen

•

2 enters calls up the Load File screen

•

3 calls up the Misc. Settings screen

•

4 calls up the Tests screen

•

F1 “PSWD” key calls up the Password Setting screen

•

F2 “QUIT” key exits without saving

•

F3 “SAVE” key exits and saves the new selections

Setup Utility Version 1.5 123 1. Power Management 2. Load File 3. Misc. Settings 4. Tests PSWD F1

QUIT F2

SAVE F3

Power Management Screen This screen is a group of four menu items for setting the power management parameters. The keys and actions for the Power Management screen are as follows:

2-14

•

1 calls up the Doze Time screen

•

2 calls up the Backlight Timeout screen

•

3 calls up the Auto-shutoff Time screen

•

4 calls up the Power Management II screen

•

F1 “BACK” returns to the main menu

Page 47

User Interface

2

T2090-TM Power Management Version X.X 123 1. Doze Time 2. Backlight Timeout 3. Auto-shutoff Time 4. Next Menu BACK F1

F2

F3

Doze time can be set from 0 to 15 seconds. Settings 1 through 8 are in 1/8second increments, while settings 9 to 15 are full, one-second increments. The valid range time for both backlight timeout and auto-shutoff time is from 1 to 15 minutes. Item 4, Next Menu, takes you to a second power management screen for configuring the key and choosing a preferred shut-down mode. See Chapter 7 for more information on Power Management.

L

Note: Timeout periods are sequential; that is, the doze countdown timer must trigger before the countdown begins for backlight (SLEEP mode), and the backlight countdown timer must trigger before the auto-shutoff countdown timer begins. If you set doze to 10 seconds, backlight to one minute, and auto-shutoff to two minutes, the auto-shutoff will occur (from the ON state) after three minutes, 10 seconds.

Set Doze Time Screen The keys and actions for the Set Doze Time, Backlight, and Auto-Shutoff Time screens are as follows: •

0 - 8 enters the time.

•

F1 “ABORT” key returns to the main menu without saving new values.

•

F3 “ACCEPT” or ENTER keys accepts new values and returns to the main menu. Set Doze Time

123

Doze Time (0 - 8): _ in 1/8 seconds Current is: 5/8 sec. ABORT F1

F2

ACCEPT F3

2-15

Page 48

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Backlight Timeout Screen Keys and actions for the Set Backlight Time screen are as follows: •

0 - 9 enters the time. (Valid entries are 0 through 15.) Where you see the underline in the screen is where the entry is displayed.

•

F1 “ABORT” key returns to the main menu without saving new values.

•

F3 “ACCEPT” or ENTER keys accepts new values and returns to the main menu.

Set Backlight Timer 123 Backlight timeout: (0 - 15 min.) __ Current is: 1 ABORT F1

F2

ACCEPT F3

Set Auto-Shutoff Screen Keys and actions for the Set Auto Shutoff Time are as follows: •

0 - 9 enters the time. (Valid entries are 0 through 15.) Where you see the underline in the figure is where the entry is displayed.

•

F1 “ABORT” key returns to the main menu without saving new values.

•

F3 “ACCEPT” or ENTER keys accepts new values and returns to the main menu.

Set Auto-Shutoff

123

Auto-shutoff time: (0 - 15 min.) __ Current is: 15 ABORT F1

2-16

F2

ACCEPT F3

Page 49

User Interface

Power Management II Screen

L

2 L

This screen is used to set the auto shutoff mode and the key mode. The key can be configured to either turn the unit off or activate the power down mode. Keys and actions on the Power Management II screen are as follows: •

1 sets the Power Down function toggles between SUSPEND & OFF

•

2 sets the key function and toggles between OFF and Power Down. The key can be configured to enter and exit from full ON or OFF or to enter and exit reduced power states. Types of configurations and possible choices are detailed further in Chapter 7.

•

F1 “BACK” returns to the main menu.

L

L

Power Management II 123 1. Pwr Dwn = SUSPEND 2. 1/0 Key = OFF

BACK F1

F2

F3

2-17

Page 50

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Load File Screen This screen is used to load files onto the T2090’s C drive using TRANSFER, an XMODEM file transfer utility. The user can specify the baud rate. Keys and actions for the Load File screen are as follows: •

1 scrolls different baud rates: 9600, 19200, 38400, 57600 and 115200 .

•

2 enters the “Set File Name” Screen (see below).

•

3 begins receiving file using an Xmodem protocol by spawning XFER.EXE.

•

4 begins file transfer by spawning RT.BAT.

•

F1 “BACK” key returns to the main menu. Load File

123

1. BAUD Rate-9600 2. Set File Name 3. Start Load Xmodem 4. Start Load RT BACK F1

F2

F3

Set File Name Screen Keys and actions for the Set File Name screen are as follows: •

Keys 1 - 0, A - Z and the period (.) are used to enter an eight-character file name with file extension.

•

F1 “ABORT” key returns to the main menu without saving the name.

•

F3 “ACCEPT” or ENTER keys saves the name and returns to the main menu. Set File Name

123

File Name: __________ ABORT F1

2-18

F2

ACCEPT F3