Page 31

Getting Started

1

•

Select the Serial Communications Setup tab to verify and configure the PC serial communications parameters.

•

Use the application to configure the serial port parameters on the T2090.

5. Select the FileCopy tab to download or upload applications and files. •

In the PC filename and path filed, type the path and filename (FILENAME.EXE) for the file on your PC. You can select a previously used filename from a list by clicking on the down arrow. To view a list of available files on your PC, click the Browse button.

•

In the TRAKKER Antares filename field, type the drive and filename on the T2090. You can select a previously used filename from a list by clicking on the down arrow. You can only download applications to drive C.

6. Click Download to copy the file from the PC to the T2090, or click Upload to copy the file from the T2090 to the PC. 7. Click exit to close the FileCopy utility.

Definitions These terms are used in this manual: Term

Definition

Real Memory

The section of memory under 1 megabyte.

ROMDOS

A 6.22-compatible operating system developed by Datalight.

1-13

Page 32

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

ROMDISK

A virtual disk placed within flash, in accordance with the development tools of Datalight ROM-DOS version 6.22.

FLASHDISK

A virtual hard disk placed within flash in accordance with the development tools of Datalight CardTrick ver. 3.0.

Managing Files Because the T2090 keypad does not include the backslash (\) and colon (:) characters, you might want to establish a CTTY session between your T2090 and a PC (or terminal) in order to use DOS commands to manage the files on the T2090. During a CTTY session, the commands that you type on the PC keyboard are executed on the T2090. Follow these steps to establish a CTTY session: 1. Determine the baud rate that is currently set on the T2090: •

If CTTY is the first progam to use the serial port after the T2090 has been booted, then the T2090 serial port is set to 2400 baud (the DOS default).

•

Otherwise, the T2090 serial port uses the baud rate set by the last program to use the serial port. For example, if the RT batch file was run last, the baud rate is 38,400. To learn more about the RT batch file, see “REMSERV.EXE, REMOTE.BAT, and RT.BAT” in Chapter 2.

2. At the C> prompt on the T2090, type CTTY COM1 and press ENTER. 3. Place the T2090 in the dock. The dock must be connected to the PC. 4. On the PC, start a terminal emulation program, such as HyperTerminal. 5. On the PC, set the serial communications port parameters. For the COM port, specify the PC COM port to which the dock is connected. Set the baud rate to the speed you determined in Step 1. Set 8 data bits, 1 stop bit, and no parity. 6. Press Enter on the PC. The T2090 C> prompt should be displayed on the PC. The CTTY session has been established. 7. Type A:RETURN on the PC and press Enter. The T2090 A> prompt should be displayed on the PC. You can use the DIR command to list the files on the A drive of the T2090. You can use any DOS command to manipulate the files on the T2090. Note: Drive A on the T2090 is not writable. It is reserved for the pre-loaded T2090 utilities only. For details, see Chapter 2. 8. To end the CTTY session, type CTTY CON and press Enter on the PC. For more help with CTTY, you can type ? after the command to get syntax information.

1-14

Page 33

2 User Interface

Page 34

This page is a scan with no text; see it in the PDF.

Page 35

User Interface

2

This chapter describes the system software that resides on the TRAKKER T2090 computer and describes the main setup screens and display indicators.

Default System Files Files Stored on ROMDISK The following files are stored in the read-only ROMDISK (drive A): File name

Description

ROM-DOS

SYS

DOS system file

CONFIG

SYS

Resident unit configuration file

AUTOEXEC BAT

Resident autoexec file

COMMAND

COM

DOS command shell

COMMAND

HLP

Help file for DOS commands

ATTRIB

COM

File attribute program

CHOICE

COM

Batch menu choice command program

FDISK

COM

Disk utility, allows toggling of boot condition

MEM

EXE

Memory interrogator program

MODE

COM

Com port mode utility

REMOTE

BAT

Batch file for starting remote server from keyboard

REMSERV

EXE

Remote server program

TRANSFER EXE

Xmodem transfer program

DLFMT

EXE

C drive formatter

RT

BAT

Batch file for Quick REMSERV start.

SETUP

BAT

Batch file to invoke setup

FWTSETUP EXE

T2090 setup program

RS-485

COM

Utility to change COM1 to RS-485

RS-232

COM

Utility to change COM1 to RS-232

DISKVER

COM

Disk version identifier

2-3

Page 36

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

ROM-DOS.SYS The DOS system is contained in the ROM-DOS.SYS file, which is loaded into RAM after the BIOS startup completes unless a bootable C drive is detected. In that case, the DOS system as specified on the C drive takes precedence.

COMMAND.COM The command shell contains the standard 6.22 ROM-DISK commands and is located on the ROMDISK (A) drive. BREAK CLS DEL EXIT IF PAUSE REN SHIFT VERIFY

CALL COPY DIR FOR MD PROMPT RENAME TIME VOL

CD CTTY ECHO GOTO MKDIR RD RMDIR TYPE

CHDIR DATE ERASE HELP PATH REM SET VER

Modifications and Special Considerations The T2090 keypad does not contain the backslash (\) and colon (:) characters, which are typically needed for many CD commands and for selecting drives. None of these commands have been modified from standard PC DOS screen format to the T2090 screen, because given the read-only nature of information on drive A, it is assumed that the average end user would only work within drive C and have little need to run DOS commands from the prompt. You can use any DOS command and access all the keys on a standard PC keyboard by establishing a CTTY session between your PC and the T2090. For help, see “Managing Files” in Chapter 1

CONFIG.SYS A default CONFIG.SYS file resides on ROMDISK, which is the read-only A drive of the T2090. This is a minimal configuration file which you cannot customize. However, you can create a customized CONFIG.SYS file on the C drive. Each time the CONFIG.SYS file on the A drive is invoked, it executes all of its command code and then calls the CONFIG.SYS file on the C drive. If the file exists, it is invoked. If not, the message “Bad or Missing NewFile file” appears. Note: “Bad or Missing NewFile file“ also appears the first time you boot the T2090 because the computer by default does not contain a CONFIG.SYS file on the C drive. Similarly, the A drive AUTOEXEC.BAT file executes next and calls the AUTOEXEC.BAT file located on the C drive.

2-4

Page 37

User Interface

2

If you do not create the configuration files on the C drive, the two minimal configuration files located on the A drive, which cannot be altered, effectively boot the system. (As described in the next section, if AUTOEXEC.BAT on the A drive does not find the configuration files on the C drive, it creates a minimal version of each file there.)

AUTOEXEC.BAT The resident AUTOEXEC.BAT file performs the following activities: •

Run the T2090 setup on detection of FWT environment variable set to ON. At boot, this variable is set to OFF or ON based on detection of the F1 key. (positive detection = ON). Like any other environmental variable, it may be altered or interrogated by batch files and programs.

•

Run the T2090 setup if AUTOEXEC.BAT or CONFIG.SYS not found on C drive.

•

Set the minimal path to be A:\;C:\.

•

Set the prompt to include drive identifier and > symbol.

•

Create a minimal CONFIG.SYS file in the root directory of C:\ if not found.

•

Create a minimal AUTOEXEC.BAT file in the root directory of C:\ if not found.

•

Change operational drive to C.

•

Execute C:\AUTOEXEC.BAT file.

Utility Programs The following utility programs and one help file are located on ROMDISK: •

COMMAND.HLP

•

TRANSFER.EXE

•

XFER.EXE

•

REMSERV.EXE, REMOTE.BAT, and RT.BAT

•

FWTSETUP.EXE

•

CLEANUP.EXE

COMMAND.HLP This file will be used in conjunction with the HELP command. You can use the HELP command to display syntax information for any command: c> help command

2-5

Page 38

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

TRANSFER.EXE Provides serial transfer of files via XMODEM or YMODEM protocols into and out of the unit. The program runs on the T2090 and can be found in the PSK software toolkit in the INTERMEC\IMT209\SAMPLE directory.

Syntax c> transfer {options} {filenames} where options are: -Q

Quiet mode. Titles, messages, and status lines are not displayed.

-M

Messages are not displayed. The title and status line may appear.

-I

Status line is not displayed. The title and messages may appear.

-Bnnn

Baud rate, where nnn may be 110, 300, 600, 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 11500, or 115 (short for 115200)

-R

Receive the file. You must specify either this option or -S.

-S

Send the file. You must specify either this option or -R.

-COMn

COM port, where n is the port number. Set n to 1. (Default)

-Pprotocol

Protocol, where protocol is XMODEM, XMODEMCRC (default), XMODEM1K, XMODEMG, YMODEM, YMODEMG, YMODEMI, or KERMIT. Keep in mind these notes about the protocols: •

XMODEMCRC provides 1K block transmission with CRC and fall back to Checksum mode.

•

XMODEM1K is only 1K block transmission with CRC.

•

XMODEM is 128 byte block transmission with Checksum.

•

XMODEMG and YMODEMG assume an errorless connection, typically used with MNP connections.

•

YMODEMI is a special variant of YMODEM that allows a file name to be specified on receive to which the first received file is written.

where filenames are: filenames

2-6

File names depend on the protocol and the send/receive option: •

For all XMODEM types, both send and receive require a file name.

•

For all YMODEM types and KERMIT, the send requires at least one file name and will accept multiple names separated by a space.

•

For YMODEMI, a file name is optional for receiving the first file and altering its name. If the sender continues with additional files they will be stored per normal YMODEM standards.

Page 39

User Interface

2

XFER.EXE This is a custom version of TRANSFER.EXE which waits for the T2090 to be placed in the dock. This utility should be used to initiate XMODEM transfers on the T2090. It does not run on a PC.

Syntax c> xfer {options} filename where options are: -r -s -B# -COM#

Receive file Send file Sets the baud rate to 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 (Default = 9600) Specify COM port 1 (must be 1) (Default)

REMSERV.EXE, REMOTE.BAT, and RT.BAT Provides remote disk access to a server via the COM port. The program REMDISK.EXE must be run on the remote server for this program to function properly. This file is accessed through the batch file REMOTE.BAT, which eliminates the need for the colon (:) and slash (/) keys in the parameters. Alternatively, the RT.BAT file will start the remote, exporting the C:\ drive at 38400 bps.

Syntax c>remote {drive} [Bnnnn] [COMn] [T] where: drive

Letter designation for the T2090 drive now seen as the next logical drive to the host system.

Bnnnn

Baud rate 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 (Default = 115K) All baud rates above 9600 use the packet transmission(+ in remdisk) option automatically.

COMn

Port number 1 or 2 (Default = 1).

T

Communications Timeout value ( in seconds 2 - 3640). You should always use /T10 or greater.

?

Help

Alternate Syntax c>rt nnnn where nnnn is the baud rate without the B. The default baud rate is 38400 or 38.4k baud.

2-7

Page 40

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

FWTSETUP.EXE T2090 setup program (discussed later in this chapter in “Setup Menu”).

Syntax c>fwtsetup

CLEANUP.EXE This utility program is intended as a performance enhancer for applications that perform a large number of disk writes during their execution. To understand what this file does, it’s necessary to describe how a disk drive in flash memory operates. Flash, unlike a real disk, cannot just be written over by new data. The area to be written must first be erased. For this reason, as the flash disk is written to or as files are deleted, blocks of flash are marked as dirty (that is, used and needing erasure). When the time comes to use these blocks, valid data is copied from an entire 64K zone into a spare zone, then the dirty zone erased. The device driver itself periodically performs this cleaning operation automatically during the process of reading and writing to the C drive. This automatic cleaning typically ranges from 0.5 to 3 seconds, depending on the condition of the flash at the time. In situations where large blocks of data are to be written to the drive, or latency times for writes are important, performance can be improved by first cleaning the disk manually. CLEANUP.EXE looks at the entire drive and collects all dirty blocks, making them available for writes. This delays the need to automatically perform a cleaning function for a significant period of time.

Syntax CLEANUP 80 /S

(from the command line)

CLEANUP C:./S

(from a batch file or CTT mode)

where:

2-8

<80> specifies drive C for the T2090.

/S prevents any nonfatal messages from appearing on the screen (Silent mode).