Page 21
Getting Started
1
This chapter contains an overview of the TRAKKER T2090’s features and offers basic information about its use.
Overview of the TRAKKER T2090 The TRAKKER T2090 is a very lightweight, pocket-size computer and bar code scanner. Designed for true one-hand operation, the T2090 fits very well into repetitive data collection applications, such as inventory management, route sales, and asset tracking. Based on a DOS-compatible platform, the T2090 is well suited for application development in a standard DOS or Windows environment. When developing applications for the T2090, keep the following information in mind. The T2090 shares some of the basic building blocks of PC architecture, such as processor, memory, and communications. It differs from PCs, however, in that the display is not 80 or 132 columns and not color, there are no floppy drives, and there are certain limitations in terms of available keys. Several standard DOS commands do not produce the same results on the T2090 as they do on a DOS PC. Graphics are handled differently. Also, the T2090 interfaces with peripherals using a communications cradle instead of a direct connect. Applications created for the T2090 should use the application functions in Intermec’s software library to open COM ports and read bar codes rather than equivalent functions from other C libraries. Technical support at Intermec is always ready to assist you with any questions you may have about how the T2090 operates.
Features The TRAKKER T2090 has the following external features: •
8 line by 20 character display panel with backlight
•
A scanner read LED indicator
•
F1, F2, and F3 function keys
•
Large, centrally located ENTER key
•
Backlight on/off key
•
Keyboard mode lock key (alpha or numeric modes)
•
13 alphanumeric data entry keys
•
Integrated bar code scanner
•
Rechargeable battery pack
1-3
Page 22
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
The following picture shows the locations of the various features.
Multi-function LED
Display panel F1, F2, F3
Enter key Num/Alpha lock key
Backlight control key
Alphanumeric keys Power key Power module
EZ Dock Docking System
209XU.004
1-4
Page 23
Getting Started
1
Charging the Battery Before using the T2090, you need to fully charge the battery pack. This takes four hours or less. For information about replacing the battery pack, see the TRAKKER T2090 Battery Replacement Instruction Sheet (part number 067378) included with the TRAKKER T2090. To charge the battery: •
Place the unit into the EZ Dock Docking System. If you are charging the battery for the first time, let it charge a full four hours.
While the battery is charging, the multifunction LED blinks red. Once charged, the battery continues to receive a “trickle” charge while sitting in the dock. This is indicated by a steady green LED. Depending on the application you are running, you can operate the TRAKKER T2090 from 10 to 20 hours on a single charge. Note: The battery charger operates normally in ambient temperatures between 50° F and 104° F (10° C and 40° C). If you continually use the docking system in an environment outside this range, the battery may not charge properly. 209XU.005
1-5
Page 24
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Collecting Data With the TRAKKER T2090, you can collect data either by entering the information using the EZ Key Keypad or by scanning bar codes. The following two sections describe both methods.
About the EZ Key Keypad The TRAKKER T2090’s EZ Key keypad has 22 keys, 13 of which are used to enter the letters A through Z, the numbers 0 through 9, the dash mark (-), period (.), and apostrophe (‘). The three unlabeled keys just below the display are the F1, F2, and F3 function keys. To switch the unit on and off: •
Press the
L key to turn the unit on and off.
To switch between alpha and numeric modes: •
×
Press the key. If the unit is in numeric mode, it switches to alpha mode, and will stay in alpha mode until you press the key again to switch it back to numeric.
×
When you first start up the TRAKKER T2090, you will see “123” on the display screen. This indicates that the keypad is in numeric mode. Pressing the key toggles the keypad mode to alpha and changes the display indicator to “ABC.”
×
To turn the backlight on: •
Press the backlight key.
The backlight automatically turns off when the unit goes into the SLEEP state, but turns back on when you press any key. See Chapter 2 for information about the unit’s power states. To enter a line of data: •
1-6
Press the ENTER key.
Page 25
Getting Started
1
Entering Data Using the EZ Key Keypad To enter numbers:
×
1. If the keypad is not in numeric mode, press the key. Now when you press any letter/number key, you will enter the number on the key. 2. Press the key(s) labeled with the number(s) you want to enter. The display shows the number or numbers that you pressed. 3. Press ENTER to complete the data entry. To enter letters:
×
1. If the keypad is not in alpha mode, press the key. Now when you press any letter/number key, you will enter the letter shown on the left or right side of the key. 2. Press the key labeled with the letter you want to enter, pressing on the left or right side of the key, depending on the letter you want. For example, to enter G, press the key labeled with G and H, pressing on the left side of the key. To clear a letter, press the BS (backspace) key. 3. Press ENTER to complete the data entry. Note: The ability to correct mistakes is controlled by the application software you are running.
About Scanning The application software running on your TRAKKER T2090 controls when the bar code scanner may be activated. Intermec supplies, through the software libraries, all the necessary functions to control and configure the scanner (see Chapter 6). If the unit is not docked and a PSK function is being used (im_receive_input or im_receive_field), and if no character input keys have been pressed since the call was made, pressing the Enter key causes a scan. If character keys have been pressed, the Enter key returns the string containing the keystrokes. The readability of a bar code depends on the type of bar code symbology, distance, and the condition or clarity of the printed material. The following diagram approximates the scanning range for various bar code densities. A slight amount of scanning distance allowance must be made for the device case assembly the outer edge of which is approximately 1/2-inch from the actual laser scanner.
1-7
Page 26
In 13.82
Cm 35.1
10.0
25.4
5.0
12.7
0
0
5.0
12.7
10.0
25.4
13.82
35.1
5 Mil 3
5 7.5 Mil
2.5
10 Mil
9 13 15 Mil
20 Mil Bar Code
* In 0 Cm 0
20
Width of field in Inches/Centimeters
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
22
40 Mil Bar Code
30
55 Mil Bar Code 5 10 15 20 25 30 38.1 50.8 63.5 76.2 12.7 25.4 Typical depth of field in Inches/Centimeters *Minimum distance determined by symbol length and scan angle
36 36 91.4 209XU.011
Scanning Bar Codes This section applies only if your TRAKKER T2090 has an integrated bar code scanner. The application software running on the unit controls when the bar code scanner is activated. Note: The scanner in the T2090 cannot be used simultaneously with the serial port or when the unit is in the dock because the internal UART is shared between the scanner and the communications serial port. To scan a bar code: 1. Hold the unit between 1-36 inches from the bar code label. 2. Press and hold ENTER. Make sure the red scanner beam spans the entire bar code. The T2090 provides feedback: •
When the scanner is activated, the LED displays red. 2090XU.010
1-8
Page 27
Getting Started
1
•
If the bar code is read successfully, the LED indicator turns green for one second. You also hear a beep if the unit’s audible feature has been enabled.
•
If the bar code is not read successfully, the LED indicator turns red for one second.
•
If you release ENTER before the bar code is read successfully, the scanner and LED turn off.
EZ Dock Docking System The EZ Dock Docking System includes a Power Module and 2-Slot Cradle. The docking system serves as a storage/charging location for the TRAKKER T2090 and provides a communications link between the T2090 and the host system. The RJ-45 connectors integrated into the module can be configured for RS-232/485 device-to-host communications. To add communications and charging capacity, you can attach up to four more 2-Slot Cradles onto the initial Power Module with 2-Slot Cradle. This increases the capacity to 10 slots from one power source. Configurations with one or two cradles should use Intermec Power Supply part number 590822. Configurations with three to five cradles require the larger Power Supply, part number 590817. The docking system includes one screw and one wing nut, which you can use to hang the unit on a wall or secure it to any horizontal surface.
Transferring Data To transfer data between the TRAKKER T2090 and a host PC, you need the following: •
T2090 and an EZ Dock Docking System
•
Universal Power Supply
•
Cable from Power Module to PC host (RJ-45 to DB-25)
Transferring Files via XMODEM: The program, XFER.EXE is preloaded on the ROMDISK (drive A). This program implements XMODEM file transfer and supports both Standard Checksum and CRC16. The program also supports both 128-byte block size and 1K block size. Note: You can use a more flexible version of this program called TRANSFER.EXE. For help, see “Utility Programs” in Chapter 2.
1-9
Page 28
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
To transfer a file from a PC to the T2090: 1. On your PC, run a communications program that supports XMODEM file transfer. (You can use Intermec’s FileCopy program, described in “Using the Serial Port to Transfer Applications and Files” later in this section.) If the program provides an options menu for XMODEM settings, choose CRC16 and 1K block size. Set the connection baud rate to match what you use on the T2090. 2. Start the XMODEM send from the PC to the unit. 3. On the T2090, type: XFER -R -B38400 -COM1. (38400 is the baud rate used in this example). 4. Place the T2090 in the dock. To transfer a file from the T2090 to a PC: 1. On your PC, run a communications program that supports XMODEM file transfer. If the program provides an options menu for XMODEM settings, choose CRC16 and 1K block size. Set the connection baud rate to match what you use on the T2090. 2. On the T2090, type: XFER -S -B38400 -COM1 (38400 is the baud rate used in this example). 3. Place the T2090 in the dock. 4. Start the XMODEM receive from the PC to the unit. Note: If you plan to use XMODEM often, put the XFER command in a DOS batch file and put it on the T2090’s C drive.
Setting Up for File Sharing To set up the TRAKKER T2090 for file sharing: 1. Set up the Power Module with attached 2-Slot Cradle and apply power. 2. Place the unit into the cradle. 3. Make the cable connection between the cradle and the host PC. Note: An executable file named REMSERV.EXE resides in ROM as well as an executable batch file named RT.bat. 4. Turn the unit on. 5. At the C> prompt, type [ RT ] and press Enter.
1-10
Page 29
Getting Started
1
To set up the host PC for data communication: Log in to the directory where the file REMDISK.EXE is stored. This is an executable file supplied by Intermec and resides in the directory chosen for installing PSK (c:\intermec, by default). Note: REMDISK must be run in DOS mode; it cannot be run safely from a DOS window under Windows or Windows 95. If you are running Windows, choose EXIT from the file menu to return to DOS. If you are running Windows 95, either choose Shutdown from the Start menu and select “Restart the computer in MS-DOS Mode” or reboot and hold down the F8 key. When you get a list of choices, select “Command Prompt only.” At the C : prompt, type this command: remdisk /COM[x]: /B38400+ /+T10 where x is the number for the COM port on the PC you are using to communicate with the T2090/cradle hardware. You should see the following message on the PC display: Remote Disk VV 6.22 ( Revision XX ) Copyright ( C ) 1989-1997 Installed as drive ? :
Datalight Inc.
/com[1 or 2]/B38400+/T3
The flash drive ROM within the T2090 is now logged in as the next lettered logical drive (such as D, E, or F) on the PC and will respond to normal DOS commands, such as DIR and DEL. You can now copy, add, or delete files as needed.
Using the Serial Port to Transfer Applications and Files The instructions in this section explain how to use the FileCopy utility to download or upload applications and files between a PC or host computer and the T2090 using serial communications. First, you connect the power module’s serial port to the host, then you use the FileCopy utility that ships with the T2090’s PSK. Note: If the T2090 is not waiting for input from a PSK function, you need to start the transfer program on the TRAKKER to receive or send the file. See “Transferring Files via XMODEM.”
1-11
Page 30
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
To download or upload applications and files to or from the T2090 computer: 1. Connect the T2090 to your PC. 2. Start Microsoft Windows on your PC. 3. From Program Manager, start FileCopy. The FileCopy utility screen appears. Make sure that the Convert .EXE check box is not checked.
4. Check the serial port and serial communications parameters to verify that the settings for your PC match the values that are set for the T2090 computer’s serial port. •
1-12
Select the COM Port Setup. The TRAKKER COM Port must be set to COM1, Communication Protocol must be set to Configurable, and File Transfer Protocol must be set to XMODEM. All other parameters must be set to match the configuration of your T2090.