Page 51
User Interface
2
Miscellaneous Settings Screen This screen contains three settings: clock, show keyboard mode, and display contrast. Exiting this screen sets the display contrast whether or not the settings are saved in the main screen. Keys and their actions for MISC. Settings Screen: •
1 “Clock Settings” enters “Set Clock” screen (see below).
•
2 toggles between displaying the keyboard mode indicator in the top left corner of the display or not.
•
F1 “BACK” key returns to the main menu.
•
F2 “LIGHTER” lightens the display contrast.
•
F3 “DARKER” darkens the display contrast. MISC. Settings
123
1. Clock Settings 2. Show KBD Mode -ON
BACK F1
<<<CONTRAST>>> LIGHTER DARKER F2 F3
Set Clock Screen The Set Clock Screen has seven entry fields: month, day, year, hour, minutes, seconds and am/pm. Entering new data in a field overwrites the previous data and when the field is full, it automatically tabs to the next field, and returns to the first field when all data has been entered. If illegal data is entered, an error message is displayed and the cursor is placed on the first illegal field. The year value has to be in the range 1980 - 2099. Keys and actions for the Set Clock screen are as follows: •
0 -9 for all fields.
•
F1 “ABORT” key returns to the main menu without saving new values
•
F2 “NEXT” key tabs to the next field.
•
F3 “ACCEPT” or ENTER keys sets new values then returns to the main menu
2-19
Page 52
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Set Clock
123
Date: Time:
03/24/1997 10:30:50 am
ABORT F1
NEXT F2
ACCEPT F3
Note: If the clock has not been set or has been reset by a cold boot, the screen will appear following boot.
Tests Screen The tests screen has two selections: display memory status and test bar code scanner. Keys and actions for the Tests screen are as follows: •
1 enters the “Memory Status” screen.
•
2 enters the Scan Bar Codes screen (see below).
•
F1 “BACK” key returns to the main menu. Tests
123
1. Memory Status 2. Scan Bar Codes
BACK F1
2-20
F2
F3
Page 53
User Interface
2
Memory Status Screen This screen displays the current status of the device’s memory. Keys and actions for the Memory Status screen are as follows: •
F1 “BACK” returns to the main menu. Memory Status
Total RAM : Total Disk: Free Disk: BACK F1
F2
123
2048K 1512K 448K
F3
Test Scanner Screen Keys and actions for the Test Scanner screen are as follows: •
ENTER starts a bar code scan. The front panel LED turns RED. Once the scan has been successfully completed, the LED turns GREEN briefly and the data scanned is displayed where the underscore is shown in the figure.
•
F1 “BACK” key returns to the main menu.
Scan Bar Codes
123
Press Enter to Scan Scanned Code: ____________________ BACK F1
F2
F3
2-21
Page 54
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Password Setting Screens The Password Setting screen (available from pressing F1 on the Setup Utility screen) lets you set a password to enter the Setup Menu. The password can be up to twenty characters long. The default password is “123.” Keys and actions for both the Enter New Password and the Verify New Password screens are as follows: •
0 -9, A-Z, dash (-), comma (,), apostrophe (‘), space, and period (.) are all valid for the password.
•
F3 or ENTER enters the password. Setup Utility
123
Enter New Password: ******************** ABORT F1
F2
Setup Utility
ACCEPT F3
123
Verify New Password: ******************** ABORT F1
2-22
F2
ACCEPT F3
Page 55
3 Application Development
Page 56
Page 57
Application Development
3
This chapter describes the system architecture used in the TRAKKER 2090 and provides basic information about developing applications using the Intermec-supplied library of functions.
System Architecture The TRAKKER T2090 hardware system has been designed with three factors in mind: •
Maintain a high degree of DOS compatibility.
•
Allow application designers as much flexibility as possible in system configuration and application design.
•
Provide simple boot-up capability even if user programs cause a temporary system lockup.
At the lowest level of the system is an enhanced 80186 BIOS. This provides the hardware/software interface for all operating system functions. The BIOS has been adapted to support unique screen, keyboard, and communications features of the T2090. In all cases, the link to higher level code is made through software interrupts, thereby eliminating restrictions upon code development languages. At the BIOS level, through extensions, a device driver is incorporated for creation of the user’s drive C within the FLASH chips. Incorporation of the driver at this level ensures that DOS, when booted, can recognize the drive and, if desired, utilize system files from this drive for booting. As an additional extension, we have provided a fail-safe mechanism for boot protection.
Memory Like other PCs, the TRAKKER T2090 has only 1MB, (1,048,576 bytes) of real addressable space. Above this limit, all memory must be paged into some other address. In the T2090, the lower 640K RAM is available to DOS, less the system drivers loaded prior to DOS boot. The remainder of the real address space is used for the mapping of EMS (extended memory system) RAM, FLASH drives and the BIOS. The following table summarizes the availability of addressable memory.
3-3
Page 58
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Address Range
Use
FFFF:Fh
BIOS
F000:0h EFFF:Fh
Device Driver Mapping
E000:0h DFFF:Fh
Unavailable
D000:0h CFFF:Fh
Drive A and drive C mapping
C000:0h BFFF:Fh
Unavailable
B000:0h AFFF:Fh
EMS Mapping
A000:0h 9FFF:Fh
Application RAM
0000:0h
Development Environment The TRAKKER T2090 has a DOS 6.22 compatible operating system. Contained within the T2090 are utilities to assist in application development. Additionally, a development library exists for C language applications.
QuickStart Kit Contents In most cases this manual has been distributed as part of a released QuickStart Kit, which consists of a TRAKKER T2090 unit, the EZ Dock Docking System and Universal Autoranging Power Supply, the appropriate serial cable to connect the Power Module to a host PC development system, PSK software toolkit, and a long-life nickel hydride battery. The software, supplied on either diskette or CD-ROM, consists of a C language software library for Microsoft C/C++ version 1.52, printable text files for this manual, demonstration program, and C language source code.
3-4
Page 59
Application Development
3
Compiler Requirements The software libraries distributed in support of the TRAKKER T2090 and this development kit were developed on Windows 3.11 and Windows 95, Pentium based systems in conjunction with the Microsoft Visual C/C++ version 1.52 compiler. Refer to Appendix B for correct settings and options.
Device Communications and Connectivity The TRAKKER T2090 has a single serial port for communications. The port can be configured as RS-232 via a program function call. Connection to the serial port can be found underneath the power module. Two female RJ-45 connectors reside on the power module. An RJ-45 to DB9 RS232 serial cable can be connected from the 2-slot cradle to a host computer. Intermec supplies a DOS utility called REMDISK that runs under MS-DOS 6.22, and can communicate with the T2090 via the power module. On the T2090, a utility called REMSERV can be run to communicate with the REMDISK program on the host DOS PC. This allows the user to remotely access drive C of the T2090 on the host DOS PC. Drive C will become the next available drive on the host DOS PC. If the last drive on the host DOS PC is D, the T2090 drive is now E. To run REMSERV on the T2090 and REMDISK on the PC, you can run the batch file RT on the T2090. RT is built in to the T2090, so try running it. You should get the following message: Initializing RS232 RS232 Enabled!
Press ENTER to quit.
With the T2090 sitting in the dock and REMSERV running via the RT batch file, copy REMDISK from the Intermec CD onto the host PC. On the PC, boot your computer into DOS. Type REMDISK COM1 /B38400+ on the PC to run the REMDISK program at 38400 BPS if you are connected to the PC on COM1. If you are connected to COM2, then replace COM1 with COM2 in the REMDISK command. To uninstall REMDISK on the PC, type REMDISK /U. The RT batch file sets up REMSERV on the T2090 to run at 38400 BPS. When the REMDISK utility is invoked, it will identify the drive letter which will be used to access the T2090. It uses the next logical drive on the PC; that is, if last used drive on your PC is D, then the T2090 drive is E. Select drive E, then type DIR <ENTER>.
3-5
Page 60
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
The T2090 should have a CONFIG.SYS and an AUTOEXEC.BAT file on it. You can now alter these as necessary, and you can now copy files to the T2090 by copying from your PC drives to the T2090 drive. Note: The scanner in the T2090 cannot be used simultaneously with the serial port or when the unit is in the dock, because the internal UART is shared between the scanner and the communications serial port. Drive A of the T2090 contains MS-DOS and other utilities. You can access this by going to the C> prompt on the T2090, and then typing CTTY COM1 on the T2090. On a host DOS PC, go into a terminal emulation program. CTTY uses the current baud rate on the T2090. If it is the first program to use the serial port after boot up, then the T2090 serial port will be set to 2400 baud (DOS default). If the RT batch file has been run, then the baud rate will be 38400, and so on. Set the serial communications port parameters to be the COM port you are connected to on the PC to the baud rate of the T2090, 8 data bits, 1 stop bit, and no parity. Press the ENTER key on the host DOS PC, and you should see C> on the host PC. Type A: <ENTER>, and you should now have the A> prompt. To see a list of the files, run the DOS DIR command. You can exit the remote access CTTY COM1 mode by typing CTTY CON on the PC. Note: Drive A is not writable. It is reserved for the preloaded T2090 utilities only.
Application Library Support Intermec supplies a library (IMT209ML.LIB) to support application development for Microsoft compilers. The library functions allow the programmer to access all unique capabilities of the T2090 using the C programming language. These include serial communications, scanning, keyboard processing, sound capabilities, and power management. Link your Microsoft compiler with the library file, IMT209ML.LIB.
3-6