Configuration Command Reference
6
LRC (Longitudinal Redundancy Check) Purpose:
The Longitudinal Redundancy Check (LRC) character is an error-checking character that you can append to transmitted and received blocks of data. Note: Before you can enable LRC, you must configure the EOM command.
Syntax:
IFdata Acceptable values for data are: 0 1
Default: Scan:
LRC disabled LRC enabled
Disabled One of these bar codes: Disable LRC
Enable LRC
*$+IF0*
*$+IF1*
*$+IF0*
Example:
*$+IF1* im_command (“$+IF1”,5); will enable LRC on serial communication.
6-27
Page 172
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
MSI Purpose:
Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code. MSI code includes a start pattern, data characters, a check digit, and a stop pattern. The check digit is always transmitted.
Syntax:
CNdata Acceptable values for data are exactly two digits, corresponding to: First digit: Second digit:
Default: Scan:
0 1,2, or 3 0 or 1
Disabled Enabled - 1 modulus 10 check digit Ignored
Disabled To disable MSI, scan this bar code: Disable MSI
*$+CN01* *$+CN01*
To enable MSI and transmit a check digit, scan this bar code: MSI With 1 Modulus 10 Check Digit, Transmit Check Digit
*$+CN21* *$+CN21*
Example:
im_command (“$+CN21”,6); will enable MSI.
6-28
Page 173
Configuration Command Reference
6
Parity Purpose:
Sets the parity for the serial port. The T2090 computer uses parity for error checking in data transmissions.
Syntax:
IBdata Acceptable values for data are: 0 1 2
Default: Scan:
No parity Even parity Odd parity
Even parity One of these bar codes: No Parity
Even Parity
*$+IB0*
*$+IB1*
*$+IB0*
*$+IB1*
Odd Parity
*$+IB2*
*$+IB2*
Example:
im_command (“$+IB2”,5); will set parity to odd.
6-29
Page 174
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Poll (Polling) Purpose:
Solicits or requests data from a polled device. Note: Before you can enable Poll, you must configure the EOM and Handshake commands.
Syntax:
HBdata Acceptable values for data are: Disabled Enabled
Default: Scan:
No polling Set to FS (File Separator)
Disabled One of these bar codes: Disable Poll
Enable Poll (Set to FS)
*$+HB*
*$+HB%B*
*$+HB*
Example:
*$+HB%B* im_command (“$+HB\x1C”,5); will set poll character to FS.
Postamble Purpose:
Sets the postamble that is appended to any data you scan with the computer. Common postambles include cursor controls such as tabs or carriage return line feeds.
Syntax:
AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the computer to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.
Default:
6-30
Disabled (no characters)
Page 175
Configuration Command Reference
Scan:
6
To disable the postamble, scan this bar code: Disable Postamble
*$+AE* *$+AE*
Or:
To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble
*+/$+AE* *+/$+AE*
2. Scan a value for data from the “Full ASCII Charts” in Appendix C. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Example:
You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”
*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*
You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.
6-31
Page 176
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Preamble Purpose:
Sets the preamble that precedes any data you scan with the computer. Common preambles include a data location number or an operator number. Note: You can set the preamble to use characters from the extended ASCII character. However, you cannot scan in extended ASCII characters in the Preamble command.
Syntax:
ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the computer to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.
Default: Scan:
Disabled (no characters) To disable the preamble, scan this bar code: Disable Preamble
*$+AD* *$+AD*
Or:
To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble
*+/$+AD* *+/$+AD*
2. Scan a value for data from the “Full ASCII Charts” in Appendix C. The preamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
6-32
Page 177
Configuration Command Reference
Example:
6
You want to set a preamble that includes quotation marks. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”
*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*
You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.
RAM Drive Size Purpose:
Configures the size and use of the RAM drive (E). You can disable the RAM drive and use the additional 256K for programmable (Malloc) memory allocations or configure the RAM drive to temporarily store data and files. Important: After you set the RAM drive, you must use the Save Configuration to File reader command in Chapter 5 to save the current configuration to TR2090.CFG. Then boot the computer for the change to take effect. Note: When you boot or reset the computer, all files on the RAM drive are destroyed.
Syntax:
FRdata Acceptable values for data are: 0 16-1344
Default: Scan:
Disabled, no RAM drive RAM drive size in kilobytes (K)
Disabled To disable the RAM drive, scan this bar code: Disable RAM Drive
*$+FR0* *$+FR0*
Or:
To set the RAM drive size: 1. Scan this bar code: Enter Accumulate Mode / Set RAM Drive Size
*+/$+FR* *+/$+FR*
6-33
Page 178
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
RAM Drive Size (continued) 2. Scan a numeric value for data from these bar codes:
*0*
*1*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*0*
*2*
*4*
*6*
*8*
*1*
*3*
*5*
*7*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1* *.+1*
5. Scan this bar code to boot the computer and use the RAM drive: Reset Firmware
*-.* *-.*
6-34
Page 179
Configuration Command Reference
6
Resume Execution Purpose:
L
L
Syntax:
L
Defines the way in which the computer resumes when you press to turn on the computer. If you set this parameter to resume not allowed and you press to turn on the computer, the computer will boot and restart the default application. If you set this parameter to resume allowed and press to turn on the computer, the computer resumes exactly where it was when you turned off the computer. ERdata Acceptable values for data are: 0 1
Default: Scan:
Not allowed Allowed
Allowed One of these bar codes: Resume Execution Not Allowed
*$+ER0* *$+ER0*
Resume Execution Allowed
*$+ER1* *$+ER1*
6-35
Page 180
TRAKKER T2090 Hand-Held Batch Computer User’s Manual
Start of Message (SOM) Purpose:
SOM is the first character in a message sent to or received from the host computer through the T2090 computer’s serial port. SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: • • • • •
AFF (ACK) DLE NEG (NAK) Poll RES (EOT)
• • • •
REQ (ENQ) SEL XOFF XON
Note: Before you can enable SOM, you must configure the EOM command. Syntax:
PEdata An acceptable value for data is any ASCII character. No data will disable SOM.
Default:
\x02 (hexadecimal value for STX)
Scan:
To disable SOM, scan this bar code: Disable SOM
*$+PE* *$+PE*
Or:
To set SOM to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOM
*+/$+PE* *+/$+PE*
2. Scan a bar code for data from the “Full ASCII Charts” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Example:
im_command (“$+PE\x02”,5); will set SOM to STX.
6-36