Page 181

Configuration Command Reference

6

Stop Bits Purpose:

Sets the number of stop bits on the serial port.

Syntax:

ICdata Acceptable values for data are: 1 2

Default: Scan:

1 stop bit 2 stop bits

1 stop bit One of these bar codes: 1 Stop Bit

2 Stop Bits

*$+IC1*

*$+IC2*

*$+IC1*

Example:

*$+IC2* im_command (“$+IC2”,5); will set serial port to 2 stop bits.

Time and Date Purpose:

Sets the time and date on the computer.

Syntax:

DBdata Acceptable values for data are 12 digits corresponding to: yy mm dd hh mm ss

Default:

00-99 01-12 01-31 01-12 00-59 00-59

Year Month of the year Day of the month Hour Minutes Seconds

920101120000

6-37

Page 182

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Time and Date (continued) Scan:

To set the time and date: 1. Scan this bar code: Enter Accumulate Mode / Set Time and Date

*+/$+DB* *+/$+DB*

2. Scan a numeric value for each digit from these bar codes:

*0*

*1*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*0*

*2*

*4*

*6*

*8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

im_command (“$+DB011225010101”,16); will set the date to December 25, 2001

6-38

*1*

*3*

*5*

*7*

*9*

Page 183

Configuration Command Reference

6

Time in Seconds Purpose:

If you enable the Append Time command, you can enable the Time in Seconds command to append the seconds to each transaction transmitted from the computer. To append the time in hours and minutes, disable the Time in Seconds command.

Syntax:

DAdata Acceptable values for data are: 0 1

Default: Scan:

Disabled Enabled

Disabled One of these bar codes: Disable Time in Seconds

*$+DA0* *$+DA0*

Enable Time in Seconds

*$+DA1* *$+DA1*

6-39

Page 184

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Timeout Delay Purpose:

If handshaking is enabled, the T2090 computer expects a response to each message that is sent to the host through the serial port. The timeout delay is the amount of time the T2090 computer waits to receive a response. When the timeout expires, the T2090 computer tries sending the message again. If no response is received, a timeout error occurs.

Syntax:

IEdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8

Default: Scan:

5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec No timeout

10 seconds One of these bar codes: No Timeout Delay

Timeout Delay 5 ms

*$+IE8*

*$+IE0*

Timeout Delay 100 ms

Timeout Delay 500 ms

*$+IE1*

*$+IE2*

Timeout Delay 2 sec

Timeout Delay 10 sec

*$+IE8*

*$+IE1*

*$+IE3*

*$+IE2*

*$+IE4*

*$+IE3*

*$+IE4*

Timeout Delay 20 sec

Timeout Delay 40 sec

*$+IE5*

*$+IE6*

*$+IE5*

6-40

*$+IE0*

*$+IE6*

Page 185

Configuration Command Reference

6

Timeout Delay 60 sec

*$+IE7* *$+IE7*

Example:

im_command (“$+IE7”,5); will set timeout delay to 60 seconds.

UPC/EAN Purpose:

Enables or disables decoding of UPC-A, UPC-E, EAN-8 and EAN-13. When enabled, supplementals are auto-detected and are transmitted. UPC Preamble of System and Country Codes are detected and transmitted. Check digits for UPC-A and UPC-E are detected and transmitted. The 6 digits of UPC-E are expanded into a UPC-A 12-digit code.

Syntax:

CEdata Acceptable values for data are four, five, six, or seven digits. The first digit must be 0, 1, or 2. The other digits must be 0 or 1. 0000 0111

Default: Note

Disabled Enabled

Enabled If any of the first four digits are non-zero (and in the valid range), UPC/EAN decoding is enabled. If any of the last three digits is included, they are ignored. All digits must be in the valid ranges. Otherwise, the command is invalid and has no effect. For example, $+CE2010010 enables decoding, but S+CE012111 is invalid because the third digit is 2, so the command has no effect.

Scan:

To disable UPC/EAN, scan this bar code: Disable UPC/EAN

*$+CE0000* *$+CE0000*

6-41

Page 186

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

UPC/EAN (continued) To enable UPC/EAN, scan this bar code: Enable UPC/EAN

*$+CE1000* *$+CE1000*

Example:

im_command (“$+CE1000”,8); will enable UPC/EAN and disallow supplementals.

6-42

Page 187

7 BIOS Support

Page 188

This page is a scan with no text; see it in the PDF.

Page 189

BIOS Support

7

This chapter describes the BIOS services that are supported for the TRAKKER T2090’s keypad, display, and cursor.

Display BIOS Support BIOS display services are available in INT 10h. The TRAKKER T2090 display most closely approximates display Mode 6, a B&W CGA graphics mode. The display is 8 lines by 20 characters and supports a single character set that includes 208, 5 x 7 ASCII characters. The screen is 119 wide by 71 pixels high. Multiple screen images or display pages are not supported, only page 0 is available and accommodates text as well as graphics. The blink display attribute is not supported, but inverse video is handled in a special manner (refer to int 10h service 33h). The underline character attribute is NOT supported. The T2090 does support character enlargement (refer to int 10h service 32h). If any of the register values are illegal, the function is not performed. Service Number 00h

01h

Type

Support Notes

Set video mode

Supported but will only allow you to set the video mode to 6. The screen will be cleared each time this service is called. No registers are used. Calling this mode just clears screen, does not look at any registers. Cursor size is not supported. The cursor is a fixed size and shaped as an underscore.

Set cursor size/ Enable/Disable Cursor enable/disable cursor Inputs: ch = if bit 5 == 1 (20h) cursor is disable else if bit 5 == 0 cursor is enable

02h

Set cursor position

All other bits are ignored. Supported. Inputs: dh = cursor position ( row = 0-7 ) dl = cursor position ( col = 0-19)

7-3

Page 190

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

03h

Read Cursor position

Supported. input: bh

= page number (ignored)

output: dh = cursor position ( row = 0-7 ) dl = cursor position ( col = 0-19) ch = 20h cursor disable 00h cursor enable 04h 05h 06h

Read light-pen position Set active display page Scroll window up

Not supported. Not supported only page 0 is available and this is fixed. Supported. Graphics are not scrolled. Input: al = # of lines to scroll up (if 0, screen is cleared) bh = Attribute for lines blanked at bottom of the window Bit 2 Bit 1 Bit -------- -------- ------X 0 0 Is Normal X 0 1 Is Double Wide X 1 0 Is Double Height X 1 1 Double High & Wide 1 Reverse bl = scroll attribute 0 scroll text (no graphics on the display) 1 scroll text (but only scroll text actually written on display. Not Graphics. 2 scroll graphics (Not supported) 3 scroll graphics and text (Not supported) ch = Top Row (0 - 7) dh = Bottom Row (0 - 7)

7-4