Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 17 of 25

TRAKKER T2090 Batch Hand-Held Computer User's Manual, pages 161 to 170

Pages 161 to 170 of 246

The original document is the PDF (737 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec T2090

Page 161

Configuration Command Reference

6

Configuration Commands Via Serial Port Purpose:

Allows you to control the data the T2090 computer receives through the serial port. You can set this command to execute reader and configuration commands received through the serial port, or treat all data as data without checking for special command syntax. There are two options: Disabled All data received through the serial port is treated as data. The computer will not execute reader or configuration commands sent or encoded in the data. Enabled The computer will check for and execute all reader and configuration commands (i.e., Receive File reader command or Beep Volume change configuration command). Note: Before you can enable Configuration Commands Via Serial Port, you must configure the EOM command.

Syntax:

ITdata Acceptable values for data are: 0 2

Default: Scan:

Disabled Enabled

Enabled One of these bar codes: Commands Via Serial Port Disabled

*$+IT0* *$+IT0*

Commands Via Serial Port Enabled

*$+IT2*

*$+IT2*

6-17

Page 162

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Data Bits Purpose:

Sets the number of data bits the T2090 computer uses when communicating with another device (i.e., host computer) through the serial port.

Syntax:

IIdata Acceptable values for data are: 7 8

Default: Scan:

7 data bits 8 data bits

7 data bits One of these bar codes: 7 Data Bits

*$+II7* *$+II7*

Example:

8 Data Bits

*$+II8*

*$+II8* im_command (“$+II8”,5); will set the serial port to send and receive 8 data bits.

Display Backlight Timeout Purpose:

Defines the amount of time the backlight remains on. The backlight timeout setting significantly affects the computer’s battery life. If you set a longer backlight timeout value, you use the power in the battery pack at a faster rate.

Syntax:

DFdata Acceptable values for data are: 0 1 - 15

Default: Scan:

Disabled Timeout in minutes

10 seconds To disable the backlight timeout, scan this bar code: Disable Backlight Timeout

*$+DF00* *$+DF00*

6-18

Page 163

Configuration Command Reference

Or:

6

To set the backlight timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Backlight Timeout

*+/$+DF* *+/$+DF*

2. Scan a numeric value (one or two digits) for data from these bar codes:

*0*

*1*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*0*

*2*

*4*

*6*

*8*

*1*

*3*

*5*

*7*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

6-19

Page 164

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Display Contrast Purpose:

Defines the contrast (light or dark) of the characters against the computer screen.

Syntax:

DJdata Acceptable values for data are: 0-7 8 9

Default: Scan:

Contrast level Lighten contrast (reduce level by 1; minimum level is 0) Darken contrast (increase level by 1; maximum level is 7)

3 One of these bar codes: 0 - Light Display Contrast

1

*$+DJ0*

*$+DJ1*

2

3 - Maximum Display Contrast

*$+DJ2*

*$+DJ3*

4

5

*$+DJ4*

*$+DJ5*

*$+DJ0*

*$+DJ2*

*$+DJ3*

*$+DJ4*

*$+DJ5*

6

7 - Dark Display Contrast

*$+DJ6*

*$+DJ7*

Lighter Display Contrast

Darker Display Contrast

*$+DJ8*

*$+DJ9*

*$+DJ6*

*$+DJ8*

6-20

*$+DJ1*

*$+DJ7*

*$+DJ9*

Page 165

Configuration Command Reference

6

Display Font Type Purpose:

Selects the type or size of font that is used on the computer screen. You can set a regular size font (6x9), a font with double-height characters (6x18), or a font with double-width and double-height characters (12x18).

Syntax:

DTdata Acceptable values for data are: 0 1 2

Default: Scan:

6 pixels by 9 pixels (6x9) font 6 pixels wide by 18 pixels high (6x18) font 12 pixels wide by 18 pixels high (12x18) font

6x9 One of these bar codes: Set Display Font Type to 6x9

Set Display Font Type to 6x18

*$+DT0*

*$+DT1*

*$+DT0*

*$+DT1*

Set Display Font Type to 12x18

*$+DT2* *$+DT2*

6-21

Page 166

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

End of Message (EOM) Purpose:

Attaches an EOM to the end of a data block to indicate the end of data transmission to and from a computer. When EOM is disabled, the computer communicates in Character mode. When EOM is enabled, the computer communicates in Frame mode. You must configure a value for EOM before you can set these other serial communications commands: • • • •

Configuration Commands Via Serial Port Handshake LRC Start of Message (SOM)

If EOM is disabled or not set, you need to disable these serial communications commands. EOM cannot equal the same value that is set for SOM. You cannot set EOM to any of these values: • • • • • Syntax:

AFF (ACK) DLE NEG (NAK) Poll RES (EOT)

• • • •

REQ (ENQ) SEL XOFF XON

PFdata Acceptable values for data are one or two ASCII characters.

Default:

\x03 (hexadecimal value for ETX)

Scan:

To disable EOM, scan this bar code: Disable EOM

*$+PF* *$+PF*

Or:

To set EOM to one or two ASCII characters: 1. Scan this bar code: Enter Accumulate Mode / Set EOM

*+/$+PF* *+/$+PF*

6-22

Page 167

Configuration Command Reference

6

2. Scan one or two bar codes for data from the “Full ASCII Charts” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

im_command (“$+PF\x03”,5); will set EOM for the serial port to ETX.

Flow Control Purpose:

Regulates the data transmission through the serial port. The T2090 computer is a DTE device. XON/XOFF response and control specify that the computer responds to and transmits XON/XOFF characters. Note: Before you can enable Flow Control with the XON/XOFF options, you must disable EOM.

Syntax:

ILdata Acceptable values for data are: 0 4

Default: Scan:

None XON/XOFF response and control

None One of these bar codes: No Flow Control

XON/XOFF Response and Control

*$+IL0*

*$+IL4*

*$+IL0*

*$+IL4*

6-23

Page 168

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Handshake Purpose:

Enables or disables the handshake event that is an affirmative acknowledge to a message received through the serial port. Note: Before you can enable Handshake, you must configure the EOM command. Handshake is also referred to as AFF (affirmative acknowledge) on other Intermec data collection devices.

Syntax:

PGdata Acceptable values for data are: No data \x06

Default: Scan:

Disable handshake Enable handshake ($F is the label for \x06)

Disabled One of these bar codes: Disable Handshake

*$+PG* *$+PG*

Enable Handshake (Set to ACK)

*/D/KPG$F* *$+PG$F*

Example:

im_command (“$+PG\x06”,5); will set AFF character to ACK and enable handshaking.

6-24

Page 169

Configuration Command Reference

6

Interleaved 2 of 5 Purpose:

Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5) symbology. I 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry.

Syntax:

CAdata Acceptable values for data are: 0 2-30 98

Disabled Fixed length (even number only) Case Code (6 or 14 characters) with a check digit

Variable length is not supported. Default: Scan:

Disabled One of these bar codes: Disable Interleaved 2 of 5

*$+CA0* *$+CA0*

Enable Interleaved 2 of 5, Case Code (6 or 14)

*$+CA98* *$+CA98*

Or:

To set Interleaved 2 of 5 to a fixed length: 1. Scan this bar code: Enter Accumulate Mode / Set Fixed Length

*+/$+CA* *+/$+CA*

2. Scan a numeric value for data from these bar codes. (Use even numbers 2-30 only.)

*0*

*1*

*2*

*3*

*0*

*2*

*1*

*3*

6-25

Page 170

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Interleaved 2 of 5 (continued)

*4* *4*

*6* *6*

*8* *8*

3. Scan this bar code to exit: Exit Accumulate Mode

*-/* *-/*

Example:

im_command (“$+CA16”,6); will enable I2 of 5 with a fixed length of 16 characters.

Example:

im_command (“$+CA98”,6); will enable I2 of 5 Case Code (either 6 or 14 characters).

Keypad Clicker Purpose:

Enables or disables the keypad clicks. The computer sounds a click each time you press a key or decode a row of a two-dimensional symbology.

Syntax:

KCdata Acceptable values for data are: 0 1

Default: Scan:

Disabled One of these bar codes: Disable Keypad Clicker

Enable Keypad Clicker

*$+KC0*

*$+KC1*

*$+KC0*

6-26

Disable keypad clicker Enable keypad clicker

*$+KC1*