Page 151

Configuration Command Reference

6

Automatic Shutoff Purpose:

Defines the maximum length of time the computer remains on when there is no activity. When you do not use the computer for the length of time set with this command, the computer automatically turns off as if you had pressed to turn it off.

L

L

When you press to turn on the computer, the computer either resumes exactly where it was when you turned it off or the computer boots and restarts your application. Resume is controlled through the Resume Execution command. For help, see “Resume Execution” later in this chapter. Power Management Tip: You should use the Automatic Shutoff feature to preserve the battery pack’s power. Syntax:

EZdata Acceptable values for data are one or two digits: 0 1-15

Default: Scan:

Disabled (always on) Shutoff time in minutes

Disabled To disable automatic shutoff, scan this bar code: Disable Automatic Shutoff

*$+EZ0* *$+EZ0*

Or:

To set a timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff

*+/$+EZ* *+/$+EZ*

2. Scan a numeric value for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*1*

*3*

6-7

Page 152

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Automatic Shutoff (continued)

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Baud Rate Purpose:

Sets the baud rate for the serial port on the T2090 computer. The baud rate must match the baud rate of the device (i.e., the host computer) that the T2090 computer is communicating with through the serial port.

Syntax:

IAdata Acceptable values for data are: 3 4 5 6 7 8 9 A

Default: Scan:

1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud 57600 baud 115200 baud

19200 baud One of these bar codes: 1200 Baud

*$+IA3* *$+IA3*

6-8

2400 Baud

*$+IA4*

*$+IA4*

Page 153

Configuration Command Reference

4800 Baud

9600 Baud

*$+IA5*

*$+IA6*

19200 Baud

38400 Baud

*$+IA7*

*$+IA8*

57600 Baud

115200 Baud

*$+IA9*

*$+IAA*

*$+IA5*

*$+IA7*

*$+IA9*

Example:

6

*$+IA6*

*$+IA8*

*$+IAA* im_command (“$+IA8”,5); will set the baud rate to 38400.

Beep Volume Purpose:

Set the beep volume according to operator preference and work environment.

Syntax:

BVdata Acceptable values for data are: 0 2

Default: Scan:

Off Normal

Normal One of these bar codes: Beep Volume Off

Beep Volume Normal

*$+BV0*

*$+BV2*

*$+BV0*

*$+BV2*

6-9

Page 154

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Codabar Purpose:

Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. Start/stop code digits are always transmitted.

Syntax:

CDdata Acceptable values for data are one or two digits, corresponding to:

Default:

First digit

0 2

Disabled Enabled

Second digit

0 or 1

Ignored

Disabled

Note:

The configuration CD20 is not permitted for consistency with other Intermec products.

Scan:

One of these bar codes: Disabled

Enable ABC, Transmit ABCD Start/Stop

*$+CD00*

*$+CD11*

*$+CD00*

Example:

im_command (“$+CD11”,6); will enable codabar.

6-10

*$+CD11*

Page 155

Configuration Command Reference

6

Code 39 Purpose:

Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). The maximum character length for a label is 23 characters. The computer decodes three types of ASCII: •

Code 39 non-full ASCII

•

Code 39 full ASCII

•

Code 39 mixed-full ASCII

Code 39 non-full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:

*SAMPLE* *SAMPLE*

This label decodes as SAMPLE. Code 39 full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Charts” in Appendix C. Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:

*+S+A+M+P+L+E* *+S+A+M+P+L+E*

In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows:

*/D/E+A* */D/E+A*

6-11

Page 156

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Code 39 (continued) In the “Full ASCII Charts” in Appendix C, /D represents $ and /E represents %. If you configure the computer for Code 39 full ASCII, the computer decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:

*$%+A* *$%+A*

The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the computer will not decode this label if it is configured for full ASCII because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the computer for mixedfull ASCII. When you configure the computer for Code 39 mixed-full ASCII, the computer will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the computer for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the computer for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the computer for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. Use this table to help configure your computer. Code 39 Option

Bar Code Label

Decodes

Non-full ASCII

$%+A /D/E+A $%+A /D/E+A $%+A /D/E+A

$%+A /D/E+A No decode $%a $%a $%a

Full ASCII Mixed-full ASCII Syntax:

CBdata Acceptable values for data must be three digits, corresponding to: First digit:

6-12

0 1

Disabled Enabled with no check digit

Page 157

Configuration Command Reference

Default: Scan:

Second digit:

0 1

Ignored Ignored

Third digit:

0 1 2

Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII

6

Enable Code 39 Full ASCII with no check digit (111) To disable Code 39: Disable Code 39

*$+CB000* *$+CB000*

To enable Code 39 with non-full ASCII: Enable Code 39, non-full ASCII

*$+CB110* *$+CB110*

To enable Code 39 with full ASCII: Enable Code 39; full ASCII

*$+CB111* *$+CB111*

To enable Code 39 with mixed-full ASCII: Enable Code 39; mixed-full ASCII

*$+CB112* *$+CB112*

Example:

im_command (“$+CB110”,7); will enable code 39 non-full ASCII.

Note:

For compatibility with other Intermec products, the second digit must be included. Even though it is ignored, it must be 0 or 1. All digits must be in the valid ranges shown; otherwise, the command is invalid and has no effect.

6-13

Page 158

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Code 128 Purpose:

Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.

Syntax:

CHdata Acceptable values for data are: 0 1

Default: Scan:

Disabled Standard Code 128

Standard Code 128 One of these bar codes: Disable Code 128

Enable Standard Code 128

*$+CH0*

*$+CH1*

*$+CH0*

Notes:

*$+CH1*

If you configure Standard Code 128, the computer will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS control character as a separator for variable length fields. UCC/EAN function code 1 extensions are not supported.

Command Processing Purpose:

Command processing allows you to disable or enable reader commands. For example, you can disable the Backlight command. You may want to disable reader commands to prevent a user from accidentally entering a command, or to use data that would otherwise be treated as a command. Any bar code label that contains the 2- to 4-character commands for Command Processing is treated as a reader command unless the command is disabled.

Syntax:

DCdata Acceptable values for data are: 0 1 2

6-14

Disable all reader commands Enable all reader commands Disable override

Page 159

Configuration Command Reference

3 command0 command1

6

Enable override Disable reader command Enable reader command

The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous configuration, you disable the override. Note: The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). Default: Scan:

Enable all reader commands To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands

Enable All Reader Commands

*$+DC0*

*$+DC1*

Disable Override

Enable Override

*$+DC2*

*$+DC3*

*$+DC0*

*$+DC2*

Or:

*$+DC1*

*$+DC3*

To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing

*+/$+DC* *+/$+DC*

2. Scan the bar code to disable or enable one reader command. Abort Program

Backlight

*/$*

*%.*

*/$*

*%.*

Change Configuration

*$+* *$+*

Default/Save Configuration

Delete File

*.+*

*..--*

*.+*

*..--*

6-15

Page 160

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Command Processing (continued) Exit Accumulate Mode

*-*

(continued)

*/*

*-*

*/*

Receive File

Rename File

*.%*

*...-*

Reset

Run Program

*.%*

*-.*

*...-*

*//*

*-.*

*//*

Test and Service Mode

Transmit File

*..-.* *..-.*

*%%*

*%%*

3. Scan one of these bar codes: Disable the Command

Enable the Command

*0*

*1*

*0*

*1*

4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the computer will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Or:

To disable or enable the ability to scan multiple-read labels, scan one of these bar codes: Disable Multiple-Read Labels

Enable Multiple-Read Labels

*$+DC 0*

*$+DC 1*

*$+DC 0*

6-16

*$+DC 1*