The text of a manual · part 5 of 8
SF51 Cordless Scanner User's Guide, pages 41 to 50
Pages 41 to 50 of 76
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SF51 Scanner
Page 41
Chapter 3, Troubleshooting and Maintaining the SF51 •
PC running Microsoft Windows 2000/XP with SP1 or SP2
Before upgrading the SF51, you should fully charge the SF51 battery. For help, see “Charging the Battery” on page 3. To upgrade the SF51 1 Download the latest upgrade package from the Intermec web site at www.intermec.com. a
Go to Support > Downloads > Search Product and Software Downloads.
b
From the Select A Product drop-down list, choose Bar Code Scanners: SF51 Cordless Scanner.
c
Click the link to download the upgrade package, and save it to your PC.
2 Remove the SF51 from the charger. 3 If necessary, install the USB or RS-232 Bluetooth adapter and create a Bluetooth connection between your SF51 and your PC. For help, see the instructions that ship with the adapter. Note: Make sure that all applications on your PC are closed.
4 Start the SF51 Firmware Upgrade Utility. 5 Scan the bar code to reset to factory defaults and click Next. See “To restore default settings” on page 21 for the reset factory defaults bar code. 6 Click Browse to browse to the location of the firmware (.ldr) file. 7 Select the firmware file and click Open. 8 Enter the Bluetooth Address of the SF51 to be upgraded and click Next. 9 The Status Bar appears and the upgrade utility loads the latest firmware on your SF51. Note: Do not place the SF51 in the 1-bay or 4-bay charger during the firmware upgrade, because the SF51 may lock up. The upgrade utility notifies you when the upgrade is complete.
28
SF51 Cordless Scanner User’s Manual
Page 42
Chapter 3, Troubleshooting and Maintaining the SF51
Troubleshooting the Firmware Upgrade If the SF51 locks up during the upgrade procedure and does not respond when you press the Scan button or place it in a charger, you may still be able to connect to it from your PC and upgrade the firmware. To troubleshoot a locked up SF51 1 Make sure that the SF51 is not seated in the 1-bay or 4-bay charger. 2 From your PC, use the Bluetooth application to search for Bluetooth devices. 3 If your SF51 appears in the list, connect to it from the Bluetooth application. If your SF51 does not appear in the list, contact Intermec Support Services at 1-800-755-5505. 4 When the Bluetooth PIN Code Request box appears, enter the following case-sensitive PIN in the Bluetooth PIN Code field, and click OK: zxcvasdfqwer The Bluetooth application connects to the boot loader code on your SF51. “Intermec SF51 Boot Server” may appear in the Device Name list instead of the name of your SF51 scanner. 5 Use your Bluetooth application to connect to the Intermec SF51 Boot Server. 6 Start the SF51 Firmware Upgrade Utility. 7 Click Browse to browse to the location of the firmware (.ldr) file. Select the firmware file and click Open. 8 From the COM Port drop-down list box, select the COM port that the Intermec SF51 Boot Server is using for Bluetooth communications. 9 Click Next. The Bluetooth address of your SF51 appears, the status bar appears, and the upgrade utility upgrades your SF51 with the latest firmware. Note: The next time you connect to your PC, your SF51 device name may be “Intermec SF51 Boot Server.” When the Bluetooth PIN Code Request box appears, enter the default PIN, which is 0000. After you connect, the name and Bluetooth address of your SF51 should appear in your Bluetooth application. SF51 Cordless Scanner User’s Manual
29
Page 43
Chapter 3, Troubleshooting and Maintaining the SF51
Paging the SF51 If your SF51 is within Bluetooth communication range of your host PC, you can send the Bluetooth Device Page command from EasySet to locate the SF51. Note: If the SF51 is turned off, your host PC cannot connect to it and send the Bluetooth Device Page command. To page the SF51 1 Start EasySet version 5.4 or later. Make sure that SF51 is selected as your product. 2 Select Communication > Connect. 3 Select the appropriate COM port, and click OK. 4 Select the Send to product check box below the commands window. 5 In the EasySet Commands window, select Configuration modes and utilities > Bluetooth device page. The SF51 beeps continuously for 1 minute or until you find the SF51 and press the Scan button.
30
SF51 Cordless Scanner User’s Manual
Page 44
Chapter 3, Troubleshooting and Maintaining the SF51
Resetting the SF51 If the SF51 appears to be locked up, you can reset it. When you reset the SF51, the scanner control firmware is restarted. To reset the SF51 • Place the SF51 in the 1-bay or 4-bay charger. If you have a Bluetooth connection, the SF51 disconnects from the host device. When you reset the SF51: •
The SF51 tries to reestablish a Bluetooth connection with the host device if the SF51 initiated the Bluetooth connection.
•
The SF51 turns on and enters a discoverable state if the host device initiated the Bluetooth connection. You need to reestablish the Bluetooth connection from the host device.
Cleaning the SF51 To keep the SF51 in good working order, you may need to clean the scanner window. Clean the scanner window as often as needed for the environment in which you are using the SF51. To clean the scanner window, you can use soapy water, a solution of ammonia and water, or isopropyl alcohol. Opening the SF51 will void the warranty and may cause damage to the internal components.
To clean the scanner window 1 Dip a clean towel or rag in soapy water, ammonia and water solution, or isopropyl alcohol and wring out the excess. Wipe the scanner window. Do not allow any abrasive material to touch the window. 2 Wipe dry with a lint-free cloth.
SF51 Cordless Scanner User’s Manual
31
Page 45
Chapter 3, Troubleshooting and Maintaining the SF51
32
SF51 Cordless Scanner User’s Manual
Page 46
4 Configuration Command Reference Use this chapter to learn about the commands supported on the SF51. This chapter contains these topics: •
Using Configuration Commands
•
Configuration Commands By Function
•
SF51 Configuration Commands
33
Page 47
Chapter 4, Configuration Command Reference
Using Configuration Commands A configuration command changes the way the SF51 operates. For example, you can change the Beep Volume and make the SF51 beeper very quiet for a quiet environment. You can configure the SF51: • by sending commands to your SF51 from your PC using EasySet. For help, see “To configure the SF51 by sending commands from EasySet” on page 19.
• by sending commands to a bar code setup sheet. Then, scan the bar codes onscreen with your SF51, or print the setup sheet and scan the bar codes. You do not need a Bluetooth connection to use this method. For help, see “To configure the SF51 by scanning bar codes” on page 19.
• from your Intermec computer. Send commands to your SF51 from your Intermec computer using Intermec Settings. For help, see the procedure “To configure the SF51 from your Intermec computer” on page 20.
For a list of all the commands and their default values as they are organized in EasySet, see the next section, “Configuration Commands By Function.” For descriptions of each command organized alphabetically, see “SF51 Configuration Commands” on page 38.
34
SF51 Cordless Scanner User’s Guide
Page 48
Chapter 4, Configuration Command Reference
Configuration Commands By Function The configuration commands are grouped by function and reflect the organization of the Commands window in EasySet. Command
Default Value
See Page
Administrator reset factory defaults
N/A
38
User reset factory defaults
N/A
51
Bluetooth Command
Default Value
See Page
Bluetooth security
Active
40
Bluetooth PIN
0000
40
Bluetooth discoverable
Fully discoverable
7
Bluetooth profile
Serial port profile (SPP)
40
Bluetooth device name
SF51 Scanner <Bluetooth Address>
7
Bluetooth connect/ disconnect
Disconnect
39
Data Transmission Command
Default Value
See Page
Data editing
N/A
43
Postamble
<CR><LF>
46
Preamble
None
46
Symbology identifier
Not transmitted
47
SF51 Cordless Scanner User’s Guide
35
Page 49
Chapter 4, Configuration Command Reference
Symbology
Default Value
See Page
Disable all symbologies
N/A
43
Codabar
Not active
41
Not active
41
Codablock Codablock A
Not active
41
Code 11
Not active
41
Code 39
Active
41
Code 93/93i
Not active
41
Code 128/EAN 128
Active
42
ISBT 128
Active
42
GTIN processing
Not active
42
EAN.UCC Composite
Not active
44
Interleaved 2 of 5
Not active
45
Matrix 2 of 5
Not active
45
Micro PDF417
Not active
45
MSI
Not active
45
PDF417
Active
45
Plessey
Not active
46
RSS 14
Not active
46
RSS Expanded
Not active
46
RSS Limited
Not active
47
Standard 2 of 5
Not active
15
Telepen
Not active
48
TLC 39
Not active
17
UPC/EAN
Active
51
ISBN
Not active
51
GTIN processing
Not active
51
Codablock F
RSS
Note: Stacked 2D bar code symbologies are only available on the PDF version of the SF51. For help setting symbology options, see the EasySet software.
36
SF51 Cordless Scanner User’s Guide
Page 50
Chapter 4, Configuration Command Reference
Trigger Activation Command
Default Value
See Page
Trigger mode
Level
49
Trigger timeout
2 sec
50
Turn off after good read Active
50
Data Decoding Security Command
Default Value
See Page
Consecutive same read data validation
Auto read count before 43 transmission
Timeout between identical consecutive codes
300 ms
48
Timeout between different consecutive codes
None
48
Default Value
See Page
Beep volume
High
39
Note (Beep frequency)
2610 Hz
38
Number
1
44
Duration
80 ms
44
Timing
After transmission
44
Good read LED duration
2000 ms
12
Error beep
On
44
Setup beep
On
15
Stacked code crackle On
47
Beeps/Green Indicator LED Command
Good read beeps
2D symbologies Vibrate alert Vibrate alert
Off
20
Duration
300 ms
52
SF51 Cordless Scanner User’s Guide
37