The text of a manual · part 4 of 8
SF51 Cordless Scanner User's Guide, pages 31 to 40
Pages 31 to 40 of 76
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SF51 Scanner
Page 31
Chapter 2, Connecting and Configuring the SF51
Collecting Data With Your SF51 After you connect your SF51 to your host device, you are ready to start collecting data. The method you use depends on whether you are using: • an Intermec computer.
• a host PC.
• the SF51 as a keyboard wedge.
To collect data with your SF51 1 Establish a Bluetooth connection. 2 Start your data collection application. 3 (Host PC only) Configure your data collection application to receive data from the incoming or outgoing COM port. 4 Scan a bar code with your SF51. The data is entered into your application. For more information, see “Connecting the SF51 to a Host Device” on page 12.
Configuring the SF51 Parameters You can configure many parameters on the SF51, such as the bar code symbologies it decodes or the volume of the beeper. These characteristics are controlled by configuration commands. The values you set for these configuration commands determine how the scanner operates. You can configure the SF51: • using EasySet version 5.4 or later.
• remotely from your Intermec computer.
Configuring the SF51 With EasySet EasySet is an Intermec configuration application that provides you with two ways to configure the SF51:
18
•
Send configuration commands directly to the SF51.
•
Send configuration commands to a bar code setup sheet. You can scan the bar codes onscreen with your SF51 or print the setup sheet and scan the bar codes. You do not need a Bluetooth connection to use this method.
SF51 Cordless Scanner User’s Guide
Page 32
Chapter 2, Connecting and Configuring the SF51 For more information about EasySet, see the EasySet software. For descriptions of the configuration commands, see Chapter 4, “Configuration Command Reference.” To configure the SF51 by sending commands from EasySet 1 Establish a Bluetooth connection with your host PC. 2 Start EasySet version 5.4 or later. The first time you start EasySet, the Select product dialog box appears. If the Select product dialog box does not appear, choose Product > Select. 3 Select the SF51. 4 Select the Online Setup check box, and click OK. The Online Setup dialog box appears. 5 Select the COM port that your SF51 is using for Bluetooth communications, and click OK. EasySet connects to your SF51 and retrieves the current configuration of the SF51. 6 In the Commands window, choose configuration command settings for your SF51. Your SF51 is updated with the new configuration command settings, and the settings are added to the bar code setup sheet. Note: The SF51 does not beep when you send configuration commands online from EasySet. To configure the SF51 by scanning bar codes 1 Start EasySet version 5.4 or later. The first time you start EasySet, the Select product dialog box appears. If the Select product dialog box does not appear, choose Product > Select. 2 Select the SF51, and click OK. 3 In the Commands window, choose configuration command settings for your SF51 and add them to the bar code setup sheet. 4 Scan the bar codes onscreen with your SF51, or print the setup sheet and scan the commands. When you scan bar code configuration commands, the SF51 emits a series of beeps unless the volume is turned off: SF51 Cordless Scanner User’s Guide
19
Page 33
Chapter 2, Connecting and Configuring the SF51 •
One beep means you scanned a valid configuration command.
•
Three beeps means you scanned an invalid configuration command.
Configuring the SF51 From Your Intermec Computer You can configure many settings for the SF51 from your Intermec computer. For descriptions of the configuration commands, see Chapter 4, “Configuration Command Reference.” Note: When you connect to an Intermec computer, all SF51 settings that are common to the Intermec computer’s internal scanner settings are changed to the default settings of the internal scanner. To configure the SF51 from your Intermec computer 1 Establish a Bluetooth connection with your Intermec computer. For help, see “Connecting to an Intermec Computer” on page 13. 2 On your Intermec computer, start the Intermec Settings application. 3 Select Data Collection > SF51 Scanner Bluetooth Address, where Bluetooth Address is the Bluetooth address of your SF51. 4 Configure commands from the SF51 Scanner menu for your SF51. 5 Select File > Save Settings. The SF51 is updated with the new configuration command settings. 6 Close Intermec Settings.
Restoring Default Settings You can restore the SF51 to its default settings by scanning the Administrator Reset Factory Defaults command. For a list of the default settings, see “Configuration Commands By Function” on page 35.
20
SF51 Cordless Scanner User’s Guide
Page 34
Chapter 2, Connecting and Configuring the SF51 Note: Using the Administrator Reset Factory Defaults command resets all parameters. As a result, you will lose Bluetooth communications. To restore default settings • Scan this bar code: Administrator Reset Factory Defaults
\60\08\55\22
Configuring Bluetooth Communications The SF51 can communicate with a host device through the Serial Port Profile (SPP) Bluetooth communications profile. SPP allows the SF51 to use the Bluetooth link as a serial port to communicate with the host device. You can send information from the SF51 to your serial application without having to modify your application. You can initiate a Bluetooth connection from either your SF51 or host device: •
If you initiate the connection from your SF51, you can only connect one SF51 to your host device. When you reset the SF51 by placing it in a charger, the SF51 automatically reestablishes the Bluetooth connection.
•
If you initiate the connection from a host device, you can connect more than one SF51 to the same host device. When you reset the SF51 by placing it in a charger, you need to reestablish the Bluetooth connection from your host device.
Configuring Security The SF51 provides Bluetooth wireless security for transmitting data. By default, security is active on your SF51. For maximum security, you need to configure a Bluetooth PIN (personal identification number). This section assumes that you have already installed EasySet version 5.4 or later. SF51 Cordless Scanner User’s Guide
21
Page 35
Chapter 2, Connecting and Configuring the SF51 To configure a Bluetooth PIN for your SF51 1 Start EasySet version 5.4 or later. 2 Select the SF51, and click OK. 3 In the Commands window, select Data transmission settings > Bluetooth parameters > security. 4 Select active. 5 Select compose PIN and create a Bluetooth PIN that is up to 16 characters in length. The default Bluetooth PIN is 0000. 6 Scan both commands onscreen with your SF51, or print the bar code setup sheet and scan both commands. Note: For security reasons, you can only change the Bluetooth PIN by scanning a bar code.
Configuring the Discoverable State of the SF51 By default, the SF51 is always discoverable. For enhanced security, you should configure your SF51 for limited discoverability, which allows the SF51 to be discoverable by Bluetooth management applications for only 30 seconds. For more information, see “Bluetooth Discoverable” on page 39. To configure your SF51 for limited discoverability • Scan this bar code: Bluetooth parameters - discoverable - limited
\60\02\50\41\00\02\40 The SF51 is discoverable for 30 seconds.
22
SF51 Cordless Scanner User’s Guide
Page 36
and 3 Troubleshooting Maintaining the SF51
Use this chapter to solve problems you may have while using the SF51. This chapter contains these topics: •
Troubleshooting the SF51
•
Upgrading the SF51
•
Paging the SF51
•
Resetting the SF51
•
Cleaning the SF51
23
Page 37
Chapter 3, Troubleshooting and Maintaining the SF51
Troubleshooting the SF51 Use this chapter to troubleshoot some common problems you may experience with your SF51. If you cannot find the answer to your problem in the “Problems and Solutions” section on page 29, you may need to call Product Support.
Calling Product Support To talk to an Intermec Product Support representative, call: 1-800-755-5505 Before you call Intermec Product Support, make sure you have the following information ready: •
Product version
•
Sub-system versions
•
Bluetooth address of your SF51
To get the product version, sub-system versions, or Bluetooth address 1 If necessary, install the USB Bluetooth adapter (P/N 203-771-xxx) or RS-232 Bluetooth adapter (P/N 203-768-xxx) and create a Bluetooth connection between your SF51 and your PC. For help, see the instructions that ship with the adapter. 2 Run an application that can accept bar code information from the SF51, such as HyperTerminal. 3 Scan these bar codes: Get Product Version
\60\0F\37\20 Get Sub-System Versions
\60\0F\37\24
24
SF51 Cordless Scanner User’s Manual
Page 38
Chapter 3, Troubleshooting and Maintaining the SF51 Get SF51 Bluetooth Device Address
\60\0F\37\23 Tip: Depending on your screen resolution, you may be able to scan bar codes displayed on your computer screen.
Problems and Possible Solutions Use this section to find problems and possible solutions.
Troubleshooting the SF51 Problem
Possible Solution
Your SF51 has been misplaced, and you cannot find it.
If your SF51 is within Bluetooth communication range of your host PC, you can send the Bluetooth Device Page command from EasySet to locate your SF51. For help, see “Paging the SF51” on page 30.
You place the SF51 in a charger and lose Bluetooth communications.
When you place the SF51 in a 1-bay or 4-bay charger, you reset the SF51, and the scanner control firmware restarts. If you have a Bluetooth connection, the SF51 disconnects from the host device while the firmware resets. For more information, see “Resetting the SF51” on page 31.
You cannot establish Scan the following bar code to reset the scanner to its default configuration and try establishing a a Bluetooth connection (the blue connection again. Using the Administrator Reset Intermec Ready-to- Factory Defaults command resets all settings. As a Work indicator is not result, you will lose Bluetooth communications. on). Administrator Reset Factory Defaults
\60\08\55\22
SF51 Cordless Scanner User’s Manual
25
Page 39
Chapter 3, Troubleshooting and Maintaining the SF51
Troubleshooting the SF51 (continued) Problem
Possible Solution
The SF51 may not be in a discoverable state. For help, You are trying to establish a Bluetooth see “Bluetooth Discoverable” on page 39. connection from a The SF51 may be connected and paired to another host device to your Bluetooth device. Scan the following bar code to reset SF51, but the host the SF51 to its default settings and disconnect device cannot find Bluetooth communications. Try establishing a your SF51. connection again. Using the Administrator Reset Factory Defaults command resets all settings. As a result, you will lose Bluetooth communications. Administrator Reset Factory Defaults
\60\08\55\22
When you press the The battery is low. Charge the battery immediately Scan button, the red and try scanning again. scanner beam does not turn on. Scan this bar code to reset the scanner to its default You changed the Bluetooth PIN from configuration and default Bluetooth PIN of 0000. its default value of Administrator Reset Factory Defaults 0000, but you forgot your new PIN number. \60\08\55\22 You established a Bluetooth connection with an Intermec computer, and the settings on your SF51 were restored to their default values.
26
When you connect to an Intermec computer, all SF51 settings that are common to the Intermec computer’s internal scanner settings are changed to the default settings of the internal scanner. Scan configuration bar codes, or use Intermec Settings on your Intermec computer to change your SF51 settings.
SF51 Cordless Scanner User’s Manual
Page 40
Chapter 3, Troubleshooting and Maintaining the SF51
Troubleshooting the SF51 (continued) Problem
Possible Solution
The data may still be in the process of being sent to You press the Scan button to scan a data the host. Data transmission may be slow if there is interference with Bluetooth communications, or if the bar code, the SF51 SF51 is too far from the host device. If you are using does not beep, and Level Trigger Mode, the scanner beam blinks while the the scanner beam SF51 is waiting. For more information, see “Trigger starts blinking. Mode” on page 49. You scan a bar code, the Status light flashes red for two seconds, and the scanner beeps three times.
The SF51 may not be connected to a host. Make sure the blue Intermec Ready-to-Work indicator is on and the SF51 is connected to your host device. For help, see “Connecting the SF51 to a Host Device” on page 12.
Try these possible solutions: You are using the SF51 in keyboard • Make sure that your data collection application is wedge mode, and open when you try to scan and running. a bar code, and • Make sure that you pressed the Keyport Lite Start nothing happens. button. For help, see “Connecting as a Keyboard Wedge” on page 14.
Upgrading the SF51 When you upgrade your SF51, you update the SF51 processor firmware. The current settings are erased and replaced with the default settings for the SF51. You need to reestablish Bluetooth communications between your SF51 and other Bluetooth devices and applications in your data collection system. To upgrade the SF51, you need these items: •
•
SF51 firmware upgrade package: •
SF51Upgrade.exe (SF51 Firmware Upgrade Utility)
•
SF51_xx_xx.ldr (firmware upgrade file)
• readme.txt (upgrade instructions)
USB Bluetooth adapter (P/N 203-771-xxx) or RS-232 Bluetooth adapter (P/N 203-768-xxx)
SF51 Cordless Scanner User’s Manual
27