Page 51

SECTION 3

Operation Modes

"

EAN-8: <BARCODE SETUP> EAN–8 ON

_

Press A or " to toggle either or then press [ENT SCAN]. "

EAN-8 Check Digit: <BARCODE SETUP> EAN–8 CHECK DIGIT SEND _

Press A or " to toggle either SEND" or then press [ENT SCAN]. "

EAN/UPC Add-On: <BARCODE SETUP> EAN/UPC ADD–ON DISABLE _

Press A or " to toggle among or then press [ENT SCAN]. "

Code 128: <BARCODE SETUP> CODE 128 ON

_

Press A or " to toggle either or then press [ENT SCAN].

M90 Series Portable Data Entry Unit Reference Manual

3-21

Page 52

Operation Modes

SECTION 3

"

EAN 128: <BARCODE SETUP> EAN 128 ON

_

Press A or " to toggle either or then press [ENT SCAN]. "

Code 93: <BARCODE SETUP> CODE 93 ON

_

Press A or " to toggle either or then press [ENT SCAN].

Terminal Configuration Select option from the Mode" menu for the Setup" menu. Parameters are set up in this menu like they are set up in the Config" menu. The M90 supports a terminal emulator that acts as a dumb ASCII computer.

Terminal ID ASCII string IDs identify each M90 Computer. IDs take up to eight characters. The initial ID is Alphanumeric characters are valid. Press [ENT SCAN] to continue. << TERM SETUP >> TERM I.D. 90

3-22

M90 Series Portable Data Entry Unit Reference Manual

Page 53

SECTION 3

Operation Modes

Online Press " to toggle between or then press [ENT SCAN]: << TERM SETUP >> ONLINE REMOTE

"

"

_

REMOTE: M90 immediately transmits scanned bar code data or key data to the host or PC using the RS-232 port. LOCAL: M90 does not transmit any data.

Echo Press " to toggle between or then press [ENT SCAN]. Set to to view any collected data. << TERM SETUP >> ECHO ON

_

AutoLF Press " to toggle between or then press [ENT SCAN]. Set to to have the M90 append a lineĆ feed (10 hex) character to the input data block. << TERM SETUP >> AUTOLF ON

_

M90 Series Portable Data Entry Unit Reference Manual

3-23

Page 54

Operation Modes

SECTION 3

Mode Press " to toggle between or then press [ENT SCAN]. << TERM SETUP >> MODE CHAR

_

Line/Page If is selected under Mode, then LINE/PAGE is enabled. The LINE/PAGE entry designates the terminaĆ tion character set as: " " "

Line termination: CR (0D hex)

Page termination: CTRL-Z (1A hex) Terminates both the line and page: CR and CTRL-Z (0D and 1A hex)

Press " to toggle among or then press [ENT SCAN]. << TERM SETUP >> LINE/PAGE LINE

3-24

_

M90 Series Portable Data Entry Unit Reference Manual

Page 55

SECTION 3

Operation Modes

Memory Configuration Select option from the Mode" menu to access the Setup" menu: <EXEC SETUP> 16KB –– 472KB OLD:236 KB NEW: _ KB

Enter the new Execution Program Area size, then press [ENT SCAN]. The M90 system RAM memory is in three sections: "

"

"

System Variable Area: Has about 29 KB reserved for system parameters. RAM Disk: Stores programs and data files, like a physical PC disk. Execution Program Area: Loads applications and data, like a PC's main memory.

Allocate the available RAM between the Execution ProĆ gram Area and RAM disk. The RAM disk size decrements when the Execution Program area size is incremented, and vice versa.

M90 Series Portable Data Entry Unit Reference Manual

3-25

Page 56

Operation Modes

SECTION 3

Alarm Select option from the Mode" menu to access the Set" menu: < ALARM SET > ALARM FUNCTION Disable

_

Press A or " to toggle among or then press [ENT SCAN]. If is selected, this screen appears: < SET ALARM > hh:mm:ss Date: Everyday Time: 08:00:00

Enter the time (24Ćhour format) that the alarm is to be set for every day. Press [ENT SCAN] to save or press and reĆ lease [FN], then " to exit without saving the entry. " NOTE:

If an incorrect entry is made, the system puts the cursor back to the beginning of the field.

If is selected, this screen appears: < SET ALARM > mm–dd–yyyy Date: 08–10–1999 Time: 08:00:00

Enter the date and time (24Ćhour format) when the alarm is to be set. Press [ENT SCAN] to save or press and release [FN], then " to exit without saving the entry. " NOTE:

3-26

If an incorrect entry is made, the system puts the cursor back to the beginning of the field.

M90 Series Portable Data Entry Unit Reference Manual

Page 57

SECTION 3

Operation Modes

Power Select option from the Mode" menu to set the power management system. The power manageĆ ment system is in the M90 Hardware and Software to inĆ crease battery service time: Any Input

Stand By

Wait Input

NMI

Stand By Timeout

Active

Power On

NMI

On

Power Fail

Shut Down

Figure 3-1 M90 Power Transition Flow "

"

"

Active: All system hardware and software continue to work if the M90 has no activity. The system may go to StandĆby mode after a timeout period. Stand By: If the keyboard, scanner, or RS-232 input are activated, the system returns to Active mode. Otherwise, the M90 waits for the specified setting timeout period, then shuts down the system. Shut Down: The M90 turns the main power off and disables all hardware devices. RAM is left on in retenĆ tion mode.

Press [1] to enter the set up menu or [2] to go to the set up menu. Press and release the [FN] key, then the " key to return to the Mode" menu. <SYSTEM ON/OFF> 1. RESUME 2. AUTO-OFF_

M90 Series Portable Data Entry Unit Reference Manual

3-27

Page 58

Operation Modes

SECTION 3

Resume The function lets the M90 resume processing from where it was when it was shut down. If off, the M90 will perform a warm start each time it is powered on again. < RESUME SET > RESUME ON

_

Press the A or " keys to toggle between or then press [ENT SCAN] to return to the On/Off" screen. Press and release the [FN] key, then the " key to return to the On/Off" screen without changes.

Auto-Off Set the timeout period from 1 to 9 MINS (minutes), or DISABLE. The unit remains on until [S1] and [FN] are pressed (off). < AUTO-OFF SET > AUTO-OFF 3 MINS

_

Press the A or " keys to toggle among the values, then press [ENT SCAN] to return to the On/Off" screen. Press and release the [FN] key, then the " key to return to the On/Off" screen without changes.

3-28

M90 Series Portable Data Entry Unit Reference Manual

Page 59

SECTION 3

Operation Modes

Password Change Select option from the Mode" menu to change the password: OLD PASSWORD: M90 NEW PASSWORD: _

A supervisor password prevents unauthorized users from entering the Supervisor Mode and changing configuration parameters. This function assigns passwords. Using up to ten alphanumeric characters key the password. Press [ENT SCAN] to save or press and release [FN], then " to exit without saving the entry.

System Initialization " NOTE: " NOTE:

Back up data or programs to the host or PC before doing this function. The M90 must be connected to a charger before entering this option.

Select option from the Mode" menu for either the Start" screen or the screen: < SYSTEM INITIAL 1.COLD START 2.PROGRAMMING _

>

M90 Series Portable Data Entry Unit Reference Manual

3-29

Page 60

Operation Modes

SECTION 3

Cold Start Select option 1. COLD START to activate the cold start. A warning screen appears: <

SYS INIT

>

Will Flush RAM & RAM Disk ! Continue ?_ 1=YES/0=NO

Press [0] to return to the Mode" menu, or press [1] to continue with the cold start.

Programming Select option 2. PROGRAMMING to access the following screen: < PROGRAMMING 1. ADD PROGRAM 2. DELETE ALL 3. UPDATE BIOS _

>

Add Program

Press [1] to add a program from the RAM disk to the FLASH disk. < PROGRAMMING

>

127 KB FLASH Free FILE1.EXE_

Press the A or " keys to toggle among the available proĆ grams on the RAM disk, then press [ENT SCAN] to add the program to the FLASH disk. While the file is added to the FLASH disk, . ." appears on the display.

3-30

M90 Series Portable Data Entry Unit Reference Manual