Page 41
SECTION 3
Operation Modes
Supervisor Mode The M90 has a Mode" to set up system configuĆ rations and verify computer hardware. Do the following to enter the Mode:" 1. Turn off the M90. 2. Press and hold the " key, then simultaneously press [S1] and [FN]. The M90 powers on with the following screen: START MENU 1. Supervisor Mode 2. Warm Start 3. Cold Start 4. Cancel
3. Press [1] to access the Mode:" <SUPERVISOR> PASSWORD: J
" NOTE:
A supervisor password prevents unauthorized users from changing configuration parameters. The M90 system forces the user to enter “Ready Mode” after five unsuccessful attempts to enter a correct password. “M90” is the default password.
M90 Series Portable Data Entry Unit Reference Manual
3-11
Page 42
Operation Modes
SECTION 3
The Mode" menu appears: 1.DEV 3.MEM 5.PWR 7.SYS
2.TERM 4.ALRM 6.PSWD 8.DIAG
These are the parameter descriptions: " " " " " " " "
1.DEV
Device Configuration
2.TERM 3.MEM 4.ALRM 5.PWR
Terminal Configuration Memory Configuration Alarm Date and Time Auto Off and Resume Configuration
6.PSWD 7.SYS 8.DIAG
Supervisor Mode Password System Initialization and Update System Diagnostics
Device Configuration " NOTE:
Defaults are given with each screen.
Select option from the Mode" menu to configure the M90 device parameters: <DEVICE CONFIG> 1.KEYPAD 2.SERIAL 3.BARCODE _
3-12
M90 Series Portable Data Entry Unit Reference Manual
Page 43
SECTION 3
Operation Modes
Keypad Select option from the Config" menu to select one of seven languages for the keypad: < KEYPAD SETUP > LANGUAGE English
_
Press A or " to toggle between the following languages, then press the [ENT SCAN] key: " "
Italian English (default)
"
Sweden/Finland Danish Spanish French
"
German
" " "
Serial " NOTE:
Defaults are given in each screen, and are listed in bold.
Select option from the Config" menu to send or receive data or programs using RS-232, and to set these and other M90 communication parameters. Press and release [FN], then press " to return to the Config" menu without changes.
M90 Series Portable Data Entry Unit Reference Manual
3-13
Page 44
Operation Modes
SECTION 3
Press [ENT SCAN] to scroll through the following parameĆ ter menus: "
Baud Rate: < COM SETUP> BAUD 19200
_
Press " to toggle between these available baud rates, then press [ENT SCAN]: "
"
150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600
Length < COM SETUP> LENGTH 8 BITS _
Press " to toggle between these bit lengths, then press [ENT SCAN]: " "
7, 8
Parity < COM SETUP> PARITY NONE _
Press " to toggle between these three parities, then press [ENT SCAN]: "
3-14
None, Odd, Even
M90 Series Portable Data Entry Unit Reference Manual
Page 45
SECTION 3
Operation Modes
"
Stop Bits < COM SETUP> STOP BITS 1 _
Press " to toggle between these stop bits, then press [ENT SCAN]: "
" NOTE:
1, 2
Flow Control controls the RS-232 port sending or receiving data in a character-by-character mode. Protocol controls file transfers. "
Flow Control < COM SETUP > FLOW CONTROL XON/XOFF _
Press " to toggle between these flow control options, then press [ENT SCAN]: "
XON/XOFF, CTS/RTS, NONE
M90 Series Portable Data Entry Unit Reference Manual
3-15
Page 46
Operation Modes
SECTION 3
Bar Code " NOTE:
Defaults are given in each screen, and are listed in bold.
Select option from the Config" menu to enter the appropriate bar code symbology supĆ ported by the M90. All bar code symbology can be sepaĆ rately enabled or disabled. See Appendix C for bar code symbologies. "
Code 39: <BARCODE SETUP> CODE 39 ON _
Press A or " to toggle this bar code symbology or then press [ENT SCAN]. "
Code 39 Full ASCII: <BARCODE SETUP> CODE 39 FULL ASCII OFF _
Press A or " to toggle this bar code symbology or then press [ENT SCAN]. "
Code 39 Start/Stop: <BARCODE SETUP> CODE 39 START/STOP NO SEND _
Press A or " to toggle either SEND" or to dictate whether to send the Code 39 start and stop character as part of the decoded data, then press [ENT SCAN]. 3-16
M90 Series Portable Data Entry Unit Reference Manual
Page 47
SECTION 3
Operation Modes
"
Code 39 Check Digit: <BARCODE SETUP> CODE 39 CHECK DIGIT OFF _
Press A or " to select one of three verification types: & NO SEND," or & SEND," then press [ENT SCAN]. "
I 2 of 5: <BARCODE SETUP> I 2 OF 5 ON _
Press A or " to toggle this bar code symbology or then press [ENT SCAN]. "
I 2 of 5 Check Digit: <BARCODE SETUP> I 2 OF 5 CHECK DIGIT OFF _
Press A or " to select one of three verification types: & NO SEND," or & SEND," then press [ENT SCAN]. "
Codabar: <BARCODE SETUP> CODABAR ON z
Press A or " to toggle this bar code symbology or then press [ENT SCAN]. M90 Series Portable Data Entry Unit Reference Manual
3-17
Page 48
Operation Modes
SECTION 3
"
Codabar Start/Stop: <BARCODE SETUP> CODABAR START/STOP SEND _
Press A or " to toggle either SEND" or to dictate whether to send the Codabar start and stop character as part of the decoded data, then press [ENT SCAN]. "
Codabar Check Digit: <BARCODE SETUP> CODABAR CHECK DIGIT OFF _
Press A or " to select one of three verification types: & NO SEND," or & SEND," then press [ENT SCAN]. "
UPC-A: <BARCODE SETUP> UPC–A ON
_
Press A or " to toggle this bar code symbology or then press [ENT SCAN]. "
UPC-A Leading Digit: <BARCODE SETUP> UPC–A LEADING DIGIT SEND _
Press A or " to toggle either SEND" or then press [ENT SCAN]. 3-18
M90 Series Portable Data Entry Unit Reference Manual
Page 49
SECTION 3
Operation Modes
"
UPC-A Check Digit: <BARCODE SETUP> UPC–A CHECK DIGIT SEND _
Press A or " to toggle either SEND" or then press [ENT SCAN]. "
UPC-E: <BARCODE SETUP> UPC–E ON
_
Press A or " to toggle this bar code symbology or then press [ENT SCAN]. "
UPC-E Leading Digit: <BARCODE SETUP> UPC–E LEADING DIGIT SEND _
Press A or " to toggle either SEND" or then press [ENT SCAN]. "
UPC-E Check Digit: <BARCODE SETUP> UPC–E CHECK DIGIT SEND _
Press A or " to toggle either SEND" or then press [ENT SCAN].
M90 Series Portable Data Entry Unit Reference Manual
3-19
Page 50
Operation Modes
SECTION 3
"
UPC-E Zero Expansion: <BARCODE SETUP> UPC–E ZERO EXPANSION OFF _
Press A or " to toggle either or then press [ENT SCAN]. "
EAN-13: <BARCODE SETUP> EAN–13 ON _
Press A or " to toggle either or then press [ENT SCAN]. "
EAN-13 Leading Digit: <BARCODE SETUP> EAN–13 LEADING DIGIT SEND _
Press A or " to toggle either SEND" or then press [ENT SCAN]. "
EAN-13 Check Digit: <BARCODE SETUP> EAN–13 CHECK DIGIT SEND _
Press A or " to toggle either SEND" or then press [ENT SCAN].
3-20