Page 31

Section 3

Operation Modes "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Ready Mode Turn on the M90 if it is not already on. Press and release [FN], then press " to go from Menu" to Mode." The following screen appears: M90 Ver X.XX MEM XXXX KB >

The first line shows the model code and version number (such as 1.60). The second line shows the total installed RAM size (such as 2048 KB). The third line is the prompt meaning that the M90 is in Ready Mode. There are eight system commands: 1. RUN Run program " 2. TER Terminal mode " 3. COM Communications " 4. DIR Directory " 5. ERA Erase file " 6. TYP Type or list file " 7. CPY Shows system parameter status " 8. SET M90 set up Input the command name at the Mode" prompt, or access the Mode," starting on the next page. "

M90 Series Portable Data Entry Unit Reference Manual

3-1

Page 32

Operation Modes

SECTION 3

User Mode Press and release the [FN] key, then press the " key to inĆ voke the Mode." The Mode" menu appears: 1. RUN 3. COM 5. ERA 7. CPY

2. TER 4. DIR 6. TYP 8. SET

Select the corresponding number, 1-8, or use Y or B to move the cursor. Press [ENT SCAN] to select a function. Press and release [FN], then press " to return to Mode."

Run Program Select option RUN" from the Mode" menu for the Program" screen: < RUN PROGRAM > PROGRAM.EXE

The Program" function gives you the possibility to run any program on the M90. Use the A or " keys to scroll to the program you want run, then press [ENT SCAN] to start the program shown on the screen. The A key will only scroll until it reaches the first file on the disk. Press and release [FN], then press " to invoke the Mode."

3-2

M90 Series Portable Data Entry Unit Reference Manual

Page 33

SECTION 3

Operation Modes

Terminal Mode Select option TER" from the Mode" menu for the screen: < TERMINAL MODE > _

In this function, the M90 serves as a dumb computer that transmits data to or receives data from a host. Bar code label data, either scanned or keyed in, go out through the RS-232 port. Data received from the serial port appear on screen. Communication parameters must be compatible between Host and M90 to send data properly. " NOTE:

The M90 has a combined “SCANNER” and “ENTER” key, thus the “ENTER” function is not active in “Terminal Mode”. Pressing the [ENT SCAN] key will activate the scanner.

Press and release [FN], then press " to return to Mode." Press and release [FN], then press " again to go to the Mode."

Communications Select option COM" from the Mode" menu for the Server Mode" screen to enter the Kermit server mode: KERMIT SERVER MODE _

Press and release [FN], then press " to go to the Mode." M90 Series Portable Data Entry Unit Reference Manual

3-3

Page 34

Operation Modes

SECTION 3

Table 3-1 indicates the available Kermit commands in the computer: Table 3-1 Kermit Commands Command

Description

SEND filename

Sends host or computer file to M90.

GET filename

Sends M90 File to host or computer disk.

REMOTE DIR

Displays directory of files stored in M90 RAM disk.

REMOTE DEL filename Deletes program or data file in M90 RAM disk.

Directory Select option DIR" from the Mode" menu to list the file directory of the M90, for example: ASET.EXE AUTOEXEC.EXE BATCHK.EXE BCRTST2.EXE

The file directory in the RAM disk appears with the followĆ ing information: "

ROM disk filenames

"

RAM disk filenames

"

Execution area size

"

Free RAM disk space

If there are more files than can be shown on the display, press [ENT SCAN] to see more files. If you are at the end of the list, pressing [ENT SCAN] takes you back to the Mode." 3-4

M90 Series Portable Data Entry Unit Reference Manual

Page 35

SECTION 3

Operation Modes

You can see that you are at the end of the list when you see the following at the bottom of the screen: TEST.EXE <<END>> X Files(s) ExecSize YYYKB Free Disk ZZZZKB_ " " " is the number of files on the disk. is the size of the execution area in KB. is the amount of free disk space in KB.

Press and release [FN], then " to return to the Mode."

Erase File Select option ERA" from the Mode" menu for the File" screen: < ERASE FILE > ERASEFIL.EXE_

This function erases files present on the M90. Use the A and " keys to scroll to the file you want erased, then press [ENT SCAN] to erase it. The A key only scrolls until it reaches the first file on the disk. When you press [ENT SCAN], you get the following mesĆ sage on the bottom of the screen to confirm whether you do want to erase the selected file: Are you sure ? 1=YES/0=NO Press [1] if you want to continue with the erase or press [0] to abort. Press and release [FN], then press " to go to the Mode." M90 Series Portable Data Entry Unit Reference Manual

3-5

Page 36

Operation Modes

SECTION 3

Type File Select option TYP" from the Mode" menu to disĆ play M90 file contents. Unintelligible characters may apĆ pear when attempting to view a program or binary file: < TYPE FILE > FILE.TXT_

Use the A and " keys to scroll to the file you want disĆ played, then press [ENT SCAN] to display it. The A key only scrolls until it reaches the first file on the disk The file displays 128 (8 lines x 16) characters per screen. Press any key to show the next page. Press and release [FN], then press " to go to the Mode."

Copy Setup Select option CPY" from the Mode" menu for the Setup" screen. Use this screen to copy files: < COPY SETUP > SOURCE FILE : _

Enter the source filename, then press [ENT SCAN] for the destination prompt: < COPY SETUP > DESTINATION : _

Enter the destination filename, then press [ENT SCAN] for the M90 to execute the copy, then return to the Mode" screen. 3-6

M90 Series Portable Data Entry Unit Reference Manual

Page 37

SECTION 3

Operation Modes

The CPY command allows you to copy data from a source and transfer the information to a different location or desĆ tination. The source and destination can be a file or device, such as port," or specifies the LCD for the destination and the keyboard for the source. Table 3-2 CPY Source and Destination Files Source

Destination

Function

File1

File2

Copy File1 to File2

File1

COM

Output content of File1 to serial port

File1

CON

Output content of File1 to LCD

COM

File2

Input data from serial port and store in File2

CON

File2

Input data from keyboard and store in File2, press and release the [FN] key, then press the " key from the keyboard to end the data input

Setup Menu Select option SET" from the Mode" menu to disĆ play the Setup" menu. Press and release the [FN] key, then press " to return to the Mode." <SYSTEM SETUP> 1.DATE & TIME 2.SCANNER 3.DISPLAY 4.EXIT

The Setup" menu contains three functions to set system parameters. Press [1] or [3] to select a category, press either [4] or [FN], then release, then press " to reĆ turn to the Mode." Press [4] or press and release [FN], then " to go to the Mode" without any changes. M90 Series Portable Data Entry Unit Reference Manual

3-7

Page 38

Operation Modes

SECTION 3

Date & Time Select option DATE & TIME" for the Date&Time" screen: <SET DATE&TIME> mm–dd–yyyy 08–09–1999

Press [ENT SCAN] if the date is correct or change the date in the month/day/year format. Be sure to enter a zero before the single digit entries. The time field appears: <SET DATE&TIME> mm–dd–yyyy 08–09–1999 hh–mm–ss 18:31:36

Press [ENT SCAN] if the time is correct to return to the Setup" menu, or change the time in the hour/minute/second format. Be sure to enter a zero before the single digit entries. The M90 uses a 24Ćhour clock. After you enter the last digit for the second, the M90 returns to the Setup" menu. Use the A and " keys to move between fields. Press and release [FN], then press " to return to the Mode" without changes to the date or time.

Scanner Select option from Setup" to enĆ able or disable the internal bar code laser scanner: <SYSTEM SETUP> SCANNER ENABLE

The M90 supports a bar code pen connected to the 10Ćpin modular connector at the bottom of the M90. Some models also come with a builtĆin laser scanner. 3-8

M90 Series Portable Data Entry Unit Reference Manual

Page 39

SECTION 3

Operation Modes

Press [ENT SCAN] to enable the internal scanner. The M90 returns a verification screen: <SYSTEM SETUP> VERIFICATION DISABLE

This screen lets you set the M90 laser scanner to decode the bar code twice before it accepts the data. Use the " key to enable or disable the two scans. When ready, press [ENT SCAN] to return to the Setup" menu. Press and release [FN], then press " to return to the tem Setup" menu without changes.

Display Select option from the Setup" menu to dictate how the cursor is to appear on the display: <SYSTEM SETUP> CURSOR SHAPE UNDERLINE

With this screen, use the " key to select either BLOCK, such as or UNDERLINE, such as When ready, press [ENT SCAN] for the Format" screen: <SYSTEM SETUP> DISPLAY FORMAT 4*12 (LARGE)

Use this screen to set a display format for the M90: " " "

"

4*12 (LARGE) 4 lines by 12 characters wide 8*16 (SMALL) 8 lines by 16 characters wide 4*20 (M80) 4 lines by 20 characters wide virtual screen, last four characters truncated 6*20 (M80) 6 lines by 20 characters wide virtual screen, last four characters truncated M90 Series Portable Data Entry Unit Reference Manual

3-9

Page 40

Operation Modes

SECTION 3

The and formats are M80Ćcompatible, such that they will only display four or six lines with the first 16 characters visible and the last four characters (positions 17ć20) truncated. A program written for the M80 is able to run without probĆ lems as the system ignores the character found outside the physical screen. Use the " key to scroll between formats. When ready, press [ENT SCAN] for the Logo" screen: <SYSTEM SETUP> POWER-ON LOGO ENABLE

Use this screen to dictate whether to have the initial powerĆ on logo appear. Press the " to toggle between and When ready, press [ENT SCAN] to reĆ turn to the Setup" screen. Press and release [FN], then press " to return to the tem Setup" menu without changes.

3-10