Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 16

M90 Series Portable Data Entry Unit Reference Manual, pages 21 to 30

Pages 21 to 30 of 156

The original document is the PDF (352 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec M90

Page 21

SECTION 1

Introduction

M90 Port Usage The M90 defines four ports. Table 1-4 shows the various port usages. See the Glossary for usage abbreviations. Table 1-4 M90 Port Usage Port

Bit

Usage

I/O

0

0 1 2 3 4 5 6 7

RTS CTS DTR SHUT213 KEY_OUT0 KEY_OUT1 KEY_OUT2 KEY_OUT3

OUT OUT OUT OUT OUT OUT OUT OUT

1

0 1 2 3 4 5 6 7

NMI/POWER FAIL WAND KEYBOARD RTC BACKLIGHT SPEAKER SOS OUT0

IN IN IN IN OUT OUT IN OUT

2

0 1 2 3 4 5 6 7

GOOD READ CS No connection SCAN_EN LCD_VO CN6ć2 (Laser control) No connection AUTOOFF

OUT OUT N/A OUT OUT OUT N/A OUT

M90 Series Portable Data Entry Unit Reference Manual

1-13

Page 22

Introduction

SECTION 1

Table 1-4 (Continued) M90 Port Usage Port

Bit

Usage

I/O

20h

0 1 2 3 4 5 6 7

BAT2_LOW PF0 No connection No connection BAT1_LOW Switch detect (Laser) COLDSTART DSR/RI

IN IN N/A N/A IN IN IN IN

Port T (keyboard) Serial channel 1 (COM port)

M90 Memory Map Table 1-5 M90 Memory Map

1-14

Address

Chip

0 ć 7FFFFh 80000h ć BFFFFh C0000h ć FFFFFh

Working RAM memory Bank switched RAM memory (RAM DISK) EEPROM (disk and OS)

M90 Series Portable Data Entry Unit Reference Manual

Page 23

SECTION 1

Introduction

M90 Input and Output All V25 Processor ports and registers in the M90 are mapped to memory. The readĆandĆwriteĆto ports act as memory that can be moved to different memory pages. Read the Internal Data in Base register (IDB) to find the actual port address. The V25 Processor does not have the same interrupt Vectors as an 8086 Processor. Table 1-6 Vector Summary Vector Number

Assigned Use

0 1 2 3 4 5 6 7 8 9 A

Divide error Break flag NMI BRK3 instruction BRKV instruction CHKIND instruction General purpose FPO instructions General purpose General purpose General purpose

B

General purpose

C

INTSER0 (serial channel 0)

D

INTSR0

E

INTST0

F

General purpose

10

INTSER1 (serial channel 1)

11

INTSR1

12

INTST1

13

I/O trap M90 Series Portable Data Entry Unit Reference Manual

1-15

Page 24

Introduction

SECTION 1

Table 1-6 (Continued) Vector Summary

1-16

Vector Number

Assigned Use

14

INTD0 (DMA channel 0)

15

INTD1

16

General purpose

17

General purpose

18

INTP0 (peripheral 0)

19

INTP1

1A

INTP2

1B

General purpose

1C

INTTU0 (timer 0)

1D

INTTU1

1E

INTTU2

1F

INTB (time base counter)

20-FF

General purpose

M90 Series Portable Data Entry Unit Reference Manual

Page 25

Section 2

System Organization "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

The software organization consists of the kernel and apĆ plication modules. The kernel modules provide basic system services for the applications. The application program of an M90 may be either resident or transient. A resident application is an application stored in the M90 EEPROM. A transient apĆ plication is an application that resides on the RAM. The host uses host file downloading commands to download the transient application. Downloadable Application Computer Module

Workstation Module

User-Device Module

Downloadable Application

Transient Applications

Resident Applications Kernel SCAN_INT

EXEC

Loader

DOS Manager

File Manager

KEYPAD_INT COM_INT

COM Manager

Figure 2-1 Software Modules M90 Series Portable Data Entry Unit Reference Manual

2-1

Page 26

System Organization

SECTION 2

An EXECutable program fundamentally controls the M90 Program. When the system powers up, EXEC performs the Power-On Test (POT). During a cold start process, the sysĆ tem restores all default configurations. A warm start proĆ cess resets the system without erasing any RAM program or data files. Device configurations preserve these program or data values as they were before the warm boot. " NOTE:

Warm start is referred to as restart in this document.

EXEC initializes all M90 Peripheral Devices respectively, according to their configuration parameters. M90 PeripherĆ als include a bar code scanner and a serial communication port (RS-232). EXEC also creates and initializes all dynamic data strucĆ tures during the startĆup process, such as a keypad queue and a COM buffer. After the initialization procedure, EXEC checks for a request for a Menu" (" key pressed while the device turns on). If there is an AUTOEXEC.EXE application in the M90, EXEC executes that application. Otherwise, the M90 enĆ ters the state, where the operator can execute M90 functions. A description of the EXEC function appears later.

Kernel The M90 Kernel provides basic system services. The kernel modules include various interrupt service routines and DOS, File, and COM managers. "

"

"

2-2

DOS Manager: Emulates most MS-DOS function calls to control M90 Peripherals and Files. File Manager: Implements a DOSĆlike file subsystem to support file operations (read, write, open, close). COM Manager: Controls the communication link beĆ tween the M90 and the host.

M90 Series Portable Data Entry Unit Reference Manual

Page 27

SECTION 2

System Organization

"

EXEC: A job scheduler that manages topĆlevel operation flow of the M90 System. The EXEC program is analogous to the COMMAND.COM program in MS-DOS operating systems:

Power-On [S1]-[FN] Pressed Simultaneously

Power-On Test

" Pressed When Power-On?

Start Menu 1 Supervisor Mode 2 Warm Start 3 Cold Start 4 Cancel

YES

NO Press [4]

NO

Press [3]

Resume Press [2]

YES System Recovers

YES

WARM START

NO

WILL DELETE ALL DATA ! Sure? 1=YES 0=NO

Press [1] Password OK and Supervisor Mode enabled

YES

YES

AUTOEXEC.EXE exist

Supervisor mode NO

Run AUTOEXEC.EXE

READY mode

WARM START

Press and release [FN], then press " (See note below) USER menu

Figure 2-2 EXEC Flow Chart " NOTE:

Press and release [FN], then press " to go from one mode to the other. M90 Series Portable Data Entry Unit Reference Manual

2-3

Page 28

System Organization

SECTION 2

When the M90 is on, the system performs a comprehensive POT. If the system passes the POT, EXEC determines whether the M90 is in Mode" or Mode." The Mode" appears if the " key is pressed while the M90 is turned on. M90 EXEC displays the superĆ visor menu while in Mode." A supervisor passĆ word protects the M90 from unauthorized entry into superĆ visor state. In normal operation M90 EXEC initializes all the input and output devices, according to the configuration. If there is an AUTOEXEC.EXE application in the unit, EXEC starts executing the application. Otherwise, EXEC displays a prompt and waits for the operator to enter further commands. "

"

2-4

Loader: The function is identical to the MS-DOS loader. The loader is an MS-DOS clone, except for the simplified memory allocation and deallocation scheme. The loader's operations are: a. Read *.EXE header. b. Find enough memory for .EXE. c. Read binary into RAM. d. Reallocate based on RAM allocation. e. Set up all registers. f. Jump to the entry point. LCD Manager: All displayable characters can appear on the LCD screen. In addition, Table 2-1 shows the special control sequences supported by the M90 DisĆ play Handler:

M90 Series Portable Data Entry Unit Reference Manual

Page 29

SECTION 2

System Organization

Table 2-1 LCD Manager Sequences

" NOTE:

Key

Hex

Operation

BEL

0x07

Activate beeper for 500 ms (0.5 seconds)

LF

0x0A

New line

CR

0x0D

Cursor return

Refer to Section 4 for detailed LCD control commands.

Workstation Mode Application Although applications are classified into resident and tranĆ sient categories, the M90 EXEC always loads the executĆ able file from the RAM/ROM into the RAM executive area. It then begins execution. Workstation mode is the default resident M90 Operation. In workstation mode, an M90 configures as a portable proĆ grammable device. The system receives transient applicaĆ tion programs from the host using a download channel. The system also receives the resident application, from ROM.59 programs or data files, that can reside on an M90. Up to eight resident applications can reside on an M90. The operator can then select one of the applications using the keypad host command sequence. The transient application operates as a file and purges when the M90 performs a cold start. While File Manager does not support the resident application, it is always in ROM. Data files or recorded information collected from workstaĆ tion applications are uploaded to the host when the host program decides to retrieve the collected data. Some apĆ plications may also require prepared data files, such as daĆ tabase information. These data files are loaded into the M90 in the same way that the program is downloaded. M90 Series Portable Data Entry Unit Reference Manual

2-5

Page 30

System Organization

SECTION 2

When the M90 is in Mode," the user menu is disĆ played. The operator may select one of the following funcĆ tions: " " " " " " " "

RUN TER COM DIR

Runs executable program Terminal mode operation Communicates in Kermit protocol Displays M90 RAM disk directory

ERA TYP CPY SET

Erases file Types file Copies file Sets M90 Parameters

Use host communication commands to perform all keypad controls. " NOTE:

2-6

If the M90 Communication Parameters are not set correctly, the host system cannot send any control commands.

M90 Series Portable Data Entry Unit Reference Manual